HAND STRIPPING PUMPS TAILPIPES TERMINATE HOW FAR OFF THE BTTOM OF THE TANK?
3/4 OF AN INCH
MOTOR STRIPPIN PUMP TAILPIPES TERMINATE HOW FAR OFF THE BOTTOM OF A TANK?
1 1/2 INCHES
WHAT ARE THE 3 INDEPENDENT SYSTEMS?
FILL & TRANSFER, STRIPPING, SERVICE
WHAT TYPE OF LOOP IS THE TRANSFER SYSTEM?
CLOSED LOOP

EACH SUCTION LINE OF A PUMP HAS WHAT TYPE OF GAGE?

COMPOUND GAGE

STRIPPING SYSTEM IS DESIGNED TO STRIP THE LAST___ INCHES?
24 INCHES
STRIPPING PUMP INLET HAS A ___MESH BASKET STRAINER?
40 MESH STRAINER
RECIRC LINES HAVE A ___ ORFICE?
5/32 INCH ORIFICE
RECIRCULATION LINES TERMINATE HOW FAR OFF THE BTTOM OF THE TANK?
18 INCHES HORIZONTALLY
WHAT TYPE OF VALVE IS ON A FLOOD AND DRAIN MANIFOLD?
GLOBE VALVE
WHAT DO DOUBLE VALVE MANIFOLDS SERVE?
BALLAST TANKS
WHAT ALLOWS ONLY ONE OPERATION AT A TIME FOR A MANIFOLD?
A SLIDING LOCK BAR
THE PRIMARY RECIEVER FOR A TLI CAN BE NO FURTHER THAN____ FT AWAY FROM THE TLI?
1000 FT
THE SECONDARY RECIEVER CAN BE ONLY____YARDS AWAY FROM THE TLI?
1000 YARDS
WHEN ARE MORE THAN ONE TRANSMITTER ROD USED FOR A TLI?
A TANK THAT IS DEEPER THAN 9FT
WHAT IS THE CAPACITY OF AN OVERFLOW LINE FROM THE TANK?
1500 GPM
WHO MAY AUTHORIZE THE ENTRY OF A TANK?
CO
HOW MANY CHANGES OF AIR ARE NEEDED TO VENTILATE A TANK?
3
What % deterioration should you submit a report to Type commander for stowage tanks?
10%
What % of deterioration in service, drain, sump and contam tanks should you submit a copy of a 2-kilo/AWR to Type commander?
1%
WHAT ARE TANKS COATED WITH AFTER BEING SANDBLASTED?
DEVRON
WHAT IS THE DIFFERENCE BETWEEN SERVICE AND STOWAGE FILL AND TRANSFER MAINS?
SERVICE HAS AN INDEPENDENT
how many transfer pumps can you align per purifier?
one only
WHAT IS THE RATED CAPACITY OF THE HAND STRIPPING PUMP?
30 GPM AT 15 PSI @ 50 DOUBLE STROKES A MINUTE
THE COMMON SUCTION HEADER PIPING ON THE TRANSFER MAIN IS HOW MANY INCHES?
6 INCHES
HOW MANY TANKS MAKE UP A NEST?
5 TANKS
WHAT IS THE FILLING RATE OF A SINGLE TANK?
500 GPM
CONTAM TANKS HAVE RELIEFS IF PRESSURE EXCEEDS___?
70 PSI
THE PRE-FLITER IS RATED AT WHAT?
250 GPM @ 150 PSI
THE RECLAIM FILTER IS RATED AT WHAT?
300 GPM @ 100 PSI
what is the filling rate of storage tanks?
500 gpm
what is the minimum amount of tanks that have to be online for filling during unrep?
6 tanks
what is the difference between the stripping tailpipe between the others?
it has no splash plate
what are the four types of tanks?
wing, peak, deep centerline and double bottom tanks
wing tanks are an integral part of what?
the ships underwater protective system
deep centerline are located where?
normally all forward tanks
double bottom tanks are usually what part of the ship?
the bottom of the tanks is the outer shell of the the ship and the tops are usually the top of the bilge
peak tanks are located where?
the extreme bow and stern of the ship below the waterline

WHAT ARE THE THREE CHAMBERS INSIDE THE FUEL FILTER?

INLET, FALLOUT, OUTLET

WHAT COMPONENT OF THE FILTER ARE INSERTED IN THE THREADED HOLES THAT ARE SYMMETRICALLY ARRANGED OVER THE SURFACE OF THE TUBE SHEETS?

FILTER ELEMENT MOUNT ASSEMBLIES

LEAKAGE IS PREVENTED AT THE ENDS OF THE FILTER ELEMENTS BY WHAT?

KNIFE EDGES ON THE END CAPS

IN WHAT DIRECTION DOES FUEL FLOW THROUGH THE COALESCER ELEMENT?

INSIDE TO OUTSIDE

THE SEPARATOR ELEMENTS HAVE THE CAPABILITY TO ONLY FILTER SOLID CONTAMINANTS LARGER THAN WHAT?

10 MICRONS

THE ROTARY CONTROL VALVE IS BOLTED TO WHAT?

WHAT RECEIVING SUMP

WHAT IS THE PRESSURE DROP LIMIT ON THE SERVICE FILTER?

15 PSI

WHAT IS THE RATED CAPACITY OF THE SERVICE FILTER?

2,000 GPM AT 150 PSI

FILTER VISUAL SAMPLES SHOULD BE TAKEN AT WHAT INTERVALS?

INITIAL FLOW, AND EVERY 15 MINUTES AFTER

WHAT ARE THE OPERATING POSITIONS OF THE ROTARY CONTROL VALVE?

DOWN, HORIZONTAL, UP

WHEN THE AUTOMATIC SHUTOFF VALVE IS OPENED BY THE FILTER DISCHARGE PRESSURE ACTING UNDER THE VALVE SEAT, WHAT PROVIDES A CUSHIONING EFFECT?

FUEL PRESSURE ACTING ON THE BOTTOM OF THE DIAPHRAGM

WHAT CAUSES THE AUTOMATIC SHUTOFF VALVE TO CLOSE WHEN THE PILOT VALVE CLOSES?

FUEL PRESSURE DIRECTED THROUGH THE EDUCTOR SUCTION LINE TO THE TOP COVER CHAMBER OF THE AUTOMATIC SHUTOFF VALVE

WHEN THE EDUCTOR CAUSES A DECREASE IN FUEL PRESSURE ON TOP OF THE DIAPHRAGM OF THE SHUTOFF VALVE, HOW WILL THE SHUTOFF VALVE BE AFFECTED?

THE TENSION SPRING WILL CLOSE THE VALVE

WHAT VALVE DIRECTS FILTER PRESSURE THROUGH ITS PORTS TO THE TOPS OF THE DIAPHRAGMS OF THE PILOT AND AUTOMATIC WATER DRAIN VALVES?

THE ROTARY CONTROL VALVE

UNDER WHAT CONDITIONS WILL THE PILOT VALVE AND AUTOMATIC SHUTOFF VALVES BE CLOSED AT THE SAME TIME?

THE FLOAT US UN THE UP POSITION AND THE ACCUMULATED WATER IS NOT DRAINING FAST ENOUGH

What is the dry weight of the filter?

10,000 pounds

What is the wet weight of the filter?

22,000 pounds

What is the operating pressure of the filter?

125 Psi



What is the hydrostatic test pressure of the filter?

278 Psi

How often is the filter element test inspection, and replacement done?

1.Every 30 months


2. when fuel samples suggest water or solids passing through elements


3. when pressure drop exceeds 15 psi


4. when filter is left drained/dry for more than 7 days

the hydrophobic screen on the filter is how many mesh?

60 mesh

What size is the monel mesh on the separator elements?

200 monel mesh

What is the minimum pressure for operating the automatic control valve?

5 Psi

How many motor driven stripping pumps are installed in the system?

5



How any hand stripping pumps are installed in the system?

2

How many transfer pumps may be used when transferring between stowage tanks?

3 tanks

Should you use steam to clean when thesaltwater system is down?

No

To whom do you report the condition of thetanks after cleaning?

Type Commander (TYCOM)