Fire detection & extinguishing

Engines (overheat & fire)


APU


Cargo compartments


Main wheel wells


Lavatories (heat activated)




Detection pwrd from battery bus


- main wheel well (dual w/ No2 AC trans bus)


- cargo compartment smoke detection pwr from DC bus 1&2



Extinguishing pwrd from hot batt bus

Engine Overheat / fire detection

2 combination overheat and fire detector loops contained in ea engine- if temp reaches limit in both detector loops triggers overheat warning, higher limit triggers fire warning


- fire switch / overheat light ext when temp blw limit



Test switch - FAULT INOP


- tests fault detection circuits for engines / APU



Test switch - OVHT/FIRE


- tests ovht and fire detection loops for engine/APU/wheel well

OVHT DET switch (center)


Test switch... OVHT/FIRE



NORMAL:


- FAULT illum = both detector loops failed


A or B:


- FAULT illum = selected detector loop fail


- + corresponding ENG OVERHEAT, engine start lever and engine fire switch remain ext

EXT TEST switch

3 green lights = circuit continuity is normal

APU fire detection

Temp in detector loop inc to limit



Warnings + APU auto shutdown



Switch light ext when temp dec blw limit



APU ground control panel in R main wheel well

APU DET INOP

APU detector loop failed

Wheel well fire detection

Dual fire detector loop


- temp in loop inc to limit



Tested w/ OVHT/FIRE test



No extinguishing, need to lower gear


- Extend speed = 270kts/.82M

Cargo compartment detection

Smoke detectors (dual loop)


- if one fails auto reconfigures to single loop detection



DET SELECT switch:


NORM = both loops active

DETECTOR FAULT

If illum when test switch pressed = 1 or more selected loops has failed



Test switch = test circuits for both fire detector loops and suppression

Cargo fire extinguisher

- FWD / AFT ARMED (red) switch pushed to arm extinguisher


- CARGO FIRE DISCH switch


- discharges 1st bottle


- 2nd bottle (reduced flow) discharges after 15mins


- DISCH illum when either bottle discharged

Lav fire detection

- smoke detector and fire extinguisher (auto activated)



Smoke detect


- Aural warning


- red status indication on lav smoke detector panel


- amber lav call light flashes



Aluminum cover indicates ext has discharged