• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/190

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

190 Cards in this Set

  • Front
  • Back
  • 3rd side (hint)

CCAS T/O inhibited alerts

Oil/Smoke


All cautions except Efis Comp, eng (ADC switch fault), Flt Ctl if TLU or ail lock or pitch disconnect, GPWS Fault, parking brake, maint pnl

T/o Inhibition canceled by

- LDG rétraction


- Pressing RCL

What is the purpose of CLR Pb

Clear all CAP amber lights except : prkg brake, gpws, maint panel


When corrective action done but malfunction remain push the clr to allow the CCAS to detect another failure

Emergency audio cancel switch

Cancels all aural alert for the entire flight exept :


- ldg


- vmo, vfe, vle


- stall


- pitch trim whooler


- AP OFF


Réactivation :


- next a/c energized


- MFC 1B/2N reset


- pressing rcl


- pressing t/o pb

Emergency audio cancel switch canceled

A/c energized again


MFC 1B/2B reset


RCL pb


T/O inhibited pb pressed

Stick shaker/pusher inhibited

On ground


10s after lift off


When descending below RA 500ft

Can CC access the cockpit when door selected off?

Yes via emergency

How to cancel emergency entry in cockpit

Deny within 30s after CC push Emergency

Deny inhibit entry and alert for ?

3min

MFC primary and alternate supply

MFC 1A : dc ess/dc emer


1B : bus 1 / main


2A : dc emer/ main


2B : Bus 2/ emer


Primary -> alter < 19V altern >22V


Altern -> primary => prim > 22v

Precautions when testing weather radar or in other position than stby

- security sector of 3m/130deg


- not during refuel of a/c or other a/c <30m


- not toward any large size metal object < 30m radius

Mrw

22970

Mrw

22970

Mtow

22800kg

Mlw

22 350 kg

MZFW

20 800 kg

Alt and T for t/o and land

-1000ft to 8500ft


- 35C to 50C

TCAS RA CLIMB or increase climb inhibition

Flaps 15 at TO AND FLAPS 30 : increase climb


In icing :


Flaps 0 z> 20 000ft RA climb


Flaps 30 climb


All increase inhibited


TCAS ground operation

Taxi : STBY


T/O : xpdr alt + tcas Auto

All TCAS RA inhibition => TA only

Climbing 1100ft


Descending 900ft

TA only

Engine out


Stick pusher/shaker failure


Flight with landing gear down

Prevent to much AOA in case of RA

Max pressure refueling

50 Psi

Each electric pump is able to supply how many engine ?

Only 1

Max TQ feather operation

66,6%

Max TQ feather operation

66,6%

Min NP in Icing condition

82%

Fuel T starting and operating

- 38 starting


- 48 operation

Feed lo pressure

4 Psi

Jet pump low pressure threshold and alert?

5psi


No alert only Run on electrical pump

Propeller anti-icing inhibited

63% NP

Fuel governing mode inhibition

EEC off or fault


PEC Off

ACW frequency

341 Hz to 488Hz

ACW frequency

341 Hz to 488Hz


115VAC

ACW engagement Np

Np 70,8%

Single DCgen opération limit

Isa + 25 20 000 ft max

Dc Gen max load

400 A none


600 A 2min


800 A 8sec

Max load TRU

60A none


90A 5min

Max load ACW

20 KVA none


30 KVA 5min


40 KVA 5s

Max load inv

500Va none


575 VA 30min


750 VA 5min

Parameters RTO

5min


Tq 100% np 100%


ITT 800c


NH 103%


OIL P 55-65 and T 0 to 125deg

Paramet T/O

TQ 90% NP 100%


ITT 740-765


NH 101%


Oil 55-65 T 0 125

MCT PARAM

TQ 90,9% (100% 42) NP 100%


ITT 800

MCT PARAM

TQ 90,9% (100% 42) NP 100%


ITT 800

CLB param

TQ 97% (109% 42) NP 82%

ITT starting

840 for 20s


950 for 5s

ATPCS arming condition (5)

A/C on ground or in flight


Pwr mgt set to T/O


Pla > 49deg


TQ > 46%


ATPCS Pb on

White bug

Vfto


Vx


VmLB0


Single engine climb speed

White bug + 10

Vy


VmHB0

TLU Auto mode HO and LO

Accélération 185kt


Décélération 180

Xwind limit without TLU

15kt


x1,5 LDR

Bleed Xfeed valve open ?

On ground with Eng 2 un hôtel mode

Bleed Xfeed valve open ?

On ground with Eng 2 un hôtel mode

Bleed valve closes when (6)

OVHT


LEAK


FIRE HANDLE


ATPCS


Starting sequence


PROP BREAK SELECTED ON FOR LEFT BLEED VALVE

Bleed duct leak

> 153deg


BLEED VALVE, HP Pack valve, Pack valve close

Bleed duct leak + consequence

> 153deg


BLEED VALVE, HP Pack valve, Pack valve close

Bleed duct ovht

> 274 deg


Can be reset

Pack valve OVHT protection

Close if T> 204deg downstream pack compressor => fault on pack pb


T> 88deg downstream of mixing chamber => temperature control valve closes to reduce hot air flow


T>92deg in duct after Mixing C => pack valve DOES NOT close + OVHT + MC

Cabin depressi rate after landing

550fpm

Cabin ROD norm and high

Normal -400fpm


High -500fpm

Cabin depressi rate after landing

550fpm

Cabin ROD norm and high

Normal -400fpm


High -500fpm

Turbofan (pack) activation

Always on ground


IAS< 150kt with LDG down or up but less than 10min


Engine low oil pressure + IAS< 150kt

How to engage YD

Depressing AP


DEpressing only YD

Does AP disengage when YD is disengaged?

Yes

AP automatic disengagement (4)

- one engagement condition is no longer meet


- stall warning


- Disagreement between 2AHRS or 2 ADC


- mismatch between 2 pitch trim

AP manual disengagement

- AP Pb


- YD pb


- AP quick disconnect pb


- action on pitch trim


- GA pb


- force > 30N on Rudder


- force > 20N on pitch

Failure which Use of AP prohibited

Pitch mistrim


Pitch trim fail

Dashes on ADU =

Loss of ASBC bus

Normal voltage reading for battery

23-28V with load


25-28V without load

Weak battery consequences

Automatic protection :


- shedding of DC SVCE + Utility Bus


- BTC open => loss of DC Bus 1


- GCU disconnect GEN 2 => loss of DC Bus 2

Main Battzry charge pb function and désactivation (3)

Close contact or between main battery and DC Bus


Automatic off when :


- thermal RWY (fault + MC)


- under voltage detected


- battery toglle switch on OVRD

Dc SVCE bus and utility bus loss

- BPCU detect abnormal operation of the bus or overload


- bus pb on FAP on shed (not visible from cockpit


- bus pb on cockpit (shed on FAP)

Reset SVCE bus

1- pb on FAP on


2- reset BTC


3- reset bus in cockpit

Fire handle pulled consequences

- feather


- engine fuel LP valve close


- engine bleed valve close


- Bleed HP valve


- de ice and isolation valve close


- désactivation of DC and AC Gen


- activation and illumination of squib

Lavatory automatic fire extinguisher trigger

78-80c

Halon and water extinguisher capacity

Halon 1kg 13s


Water 2L 40s

PAX O2

30min

Pitch trim fail and AP?

Should disconnect and not réengage

Roll trim on which aileron ?

LH

How many pitch trim tab? Supply ? Principle?

2 pitch trim on each aileron


Electrical actuator


Connected via flexible shaft

O2 Pressure before flight


02 Lo pr

1400psi


50psi

Ra fail

- dash on EADI


- GPWS Fault + other system using RA


- TCAS on STBY

Ra fail (3) indication and action

- dash on EADI


- GPWS Fault + other system using RA


- TCAS on STBY

RA range

-20 to 2500ft

Ra transmit info to

CCAS


GPWS


FDAU


AP


SGU

Ra indication

White box = 100ft above


Dh un white bow = RA < DH

Deceleration height high speed app

IAS x 10 = ft

RWY width certification

> 30m


If 14m Vmcg + 5kt

System that cannot be reset

EEC


Pec


Cab press mode sel


Bat chg


Bleed valve in case of bleed leaks


Dc Gen in case of bus failure

AHRS Accuracy

ATT +-1,4


HDG +-2

DGR on EHSI

Unable RNP

Pitch roll att disagreement trigger

> 6

CVR + DFDR activation

Auto energized with DC GEN on


Stop 10min after engine shut off

Hydraulic OVHT Trigger

121

Engine de ice fault triggered by

T> 230


P < 14 psi


Inflation sequencing incorrect


No Pressure detected but valve open


Pressure detected but valve closed

Engine de ice fault

T> 230


P < 14 psi


Inflation sequencing incorrect


No Pressure detected but valve open


Pressure detected but valve closed

Airframe de icing fault

Pressure detected but distribution valve closes


No pressure but distribution valve open

Normal mode of de icing : fast or slow ?

Fast => 60s pb released


0

WX Range

300nm


45deg on each side


15deg tilt up and down

WX Range

300nm


45deg on each side


15deg tilt up and down

Color scale in gmap mode and source of info

Black, pale blue, yellow and magenta


Use map of egpws (TAD)

When TERR pb should be released

Inhib enhanced mode Take off or approach to airport without EGPWS data base

Vmo wipers

160kt

Max xwind dry

35kt

Max xwind dry

35kt

Max Xwind braking action 5

28kt

Max xwind dry

35kt

Max Xwind braking action 5

28kt

Max Xwind braking action 4

22kt

Max xwind dry

35kt

Max Xwind braking action 5

28kt

Max Xwind braking action 4

22kt

Max Xwind braking action 3

16kt

Max xwind dry

35kt

Max Xwind braking action 5

28kt

Max Xwind braking action 4

22kt

Max Xwind braking action 3

16kt

Max Xwind braking action 2

16kt

Max xwind dry

35kt

Max Xwind braking action 5

28kt

Max Xwind braking action 4

22kt

Max Xwind braking action 3

16kt

Max Xwind braking action 2

16kt

Max Xwind braking action 1

10kt

Va

175kt

Vmcl

98kt

Vra (maximum rough air)

180kt

Speed of extract fan

Dépend on flight deck temperature


Minimum if T<20


Maximum if T > 52

When extract fan stop

OVBD pb released => OVBD val le partially open in flight


During 120s during engine start

When OVBD CLOSES AUTO

On ground with engine 1 running


In flight

Bank pb on ADU

Hi bank = max 27


Lo bank = max 15

A/erect pb illuminated amber when

Tas most from both ADC

Ap engaged and coupled with SGU failure

Both CRT on one side are lost


Upper mode lost (all mode with SGU computation )


Select valid SGU and AP Recovers

Consequence of ADC 1 failure

- Ap loss upper modes but ca be réengaged


- GPWS Inop


-Lansing élévation in pressure altitude


- incorrect torque bug pointer (show 23%)


- TAT/SAT Loss

Roll aileron trim

Electrical tab on LH aileron

How control forces is reduced on each control surfaces?

Spring tab

Pressurisation of the hydraulic system

2 Electric pump energized by ACW power


1 electric pump powered by DC Power

Hydraulic tank

Non pressurised


9,6L but low level alert on each section <2,5L

Hrydaulic system low level alert

<2,5L on each section


Xfeed valve inhibited


Check lost equipment

Hydraulic OVHT

>121 in pump drain line

Antiskid breaking action inhibited at touchdown

Wheel spin up speed > 35kts or 5s

Antiskid touch down protection

Inhibit anti skid until wheel speed > 35kt or until 5s after touchdown

Block wheel protection action

Speed > 23kts + 50% of difference speed between a wheels

Anti skid locked wheel protection

Available with a speed > 23kt


If wheel speed difference > 50% activation of this protection => brake on slower wheel is released

Anti skid availability

LDG down and locked


Speed > 10kts


But can test even in flight

Conditions for thé APM to perform calculation

APM Pb on


SAT < 10c


2 engines on


LDG Up


Flaps 0


Ice accretion detected or at Icing AOA on or Aiframe pb de icing on

Increase speed

IAS < icing bug + 10kt


in climb add the loss of ROC

Increase speed

IAS < icing bug + 10kt


in climb add the loss of ROC


= severe drag

Degraded perf

Significant decrease of IAS or ROC


=> recommanded to accelerate to icing bug + 30 or at least +10


And if not possible reduce to low bank

Break temperature Hot

150

LDG not safe CCAS alert

Any gear not down and locked


Flaps 30


RA < 500ft

Engine oil lo pr

40PSI

Yellow bug for approach

VGA = 1,1 VMCA

Fuel clog light on / fuel bypass

Light on > 25psi


Bypass > 45psi

EEC Function

- Ensure minimum prop speed control on ground and at low power


- automatic up trim


- controls opening of HBV

Fast/Slow indicator

+-5,5 to 11


25< deviation < 15 index half visible


>25 no visible


< -11 deviation remain visible

Flaps asymmetry

> 6,7

Blue ext flag on flaps indicators

= flap valve is hydraulically commanding flap extension


If flaps already extends with this flag = hydraulic leak

Flaps unlock

Spurious recreation > 4deg

Nac OVHT

170

Pack valve function

- pack shutoff


- flow control

Pack valve function

- pack shutoff


- flow control

Packs function

Regulate


- air flow


- temperature


(+ removed moisture and pressurize bleed air )

AP Engagement without FD mode or using TCS

Maintien pitch if +-15 or return to max 15 pitch


BA < 6 wing level + Maintain heading


6< BA < 35 maintain BA


BA >35 Return to 35

Loc and GS scales flash

Excessive deviation

Stall alert

Cricket

Stall alert

Cricket

Overspeed aural alert

Clacker

Ap disconnect aural warning

Cavalry

Function of emer audio pb

Cancel specific aural alert in case of false system indication

In case of MFC 1B and 2B

All level 2 + level 3 alerts : config + eng oil + prop brk » are not processed


All other level 3 processed but NO MW and CRC AND not displayed on CAP

CLR Pb

Clear only caution alert

Zone 3 Amber lights

Prkg brake / GPWS fault / maint pnl


Can be relive only by corrective action

Climb speed with icing


With ice accretion

Icing = red bug


Ice accretion = red bug + 10

Prop Anti icing model pb modes

Released = norm = 0< T < -10 = 50s cycle


Fast = - 10 < T < -30 = 80s

Prop Anti icing model pb modes

Released = norm = 0< T < -10 = 50s cycle


Fast = - 10 < T < -30 = 80s

De icing mode sel Pb

Released = fast = T > -20 = 60s


Pb in = slow = T < -20 = 180s

De icing ovrd pb function and fault

Fault : MFC modules for air intake boots control fail


OVRD : emergency de icing activation (sequence 60s)

Mode sel auto pb function and fault

Fault = MFC and/or ADC fails


FAST mode automatic activated


Function = manage boots cycle with ADC and MFC

ACW GEN on line


And give power

66% NP on line


70,8% available

Max cabin differential pressure

6,35 to -0.5

AP Pitch Actuator

RH Column

ITT Max to abort t/o

765

How jet pump motive flow valve closed?

By pump pb off

Does electrical pump goes on if fuel lo lvl ?

Yes pumps run of fuel lo lvl

In case of one loop off does engine fire is triggered ?

Yes because they are in parallèle


Engine fire :


- both loop detect fire


- only one loop

Pack valve delay ?

Left no delay


Right : 6s delay for max confort

Operations with CCAS Failure

MFC 1B 2B fail :


- MC on but do not flash


- MFC Amber light on CAP


- MFC 1B 2B fault light


=> level 2 alert + config + oil + prop brake level 3 alerts not processed


All other level 3 processed but without LW and CRC

Yaw trim ? Electrical or mechanical ?

Electrically controlled and actuated


Yaw trim motor

Évitement d’orage en zone terminale

3Nm