RT- A lead symbol "B" for backscatter radiation shall have a minimum dimensions of? Where shall it be attached during exposure?

1/2" height



1/16" thick



Shall be attached to the back of each film holder during exposure to determine backscatter radiation.

RT- what shall be used for judging film density?

Either a densitometer or step wedge comparison.

RT- image quality indicators IQI shall be of what type?

Hole type or wire type

RT- geometric unsharpness determination

Ug= Fd/D (find in Art 2, T-274)

RT- location markers, what are they to appear as and where shall they be placed?

Are to appear as radiographic images on film



Shall be placed on part, not on exposure holder / cassette

RT- for double wall viewing, at least _______ location marker shall be placed adjacent to weld for each radiograph.

One

RT- IQI's shall be selected from what alloy material group or grade?

From either the same alloy material group or grade as identified in SE-1025 or from an alloy material group or grade with less radiation absorption than the material being radiographed.

RT- Density limitations



Single film viewing X-ray and gamma ray?



Composite viewing of multiple film exposures min and maximum? Tolerances?



Art 2, T-282.1



1.8 minimum for single film viewing with X-ray source



2.0 minimum for gamma ray source



1.3 - 4.0 composite viewing of multiple film with a tolerance 0.05.

RT- Excessive backscatter criteria.

Light image of B on darker background- unacceptable



Dark image of B on lighter background- acceptable



No B- ideal

RT- IQI's are chosen based on the thickness being radiographed, this is done by?

Using table T-276.1

PT- prior to examination, the surface and all adjacent areas shall be dry and free of all dirt, grease, lint, scale, flux, spatter, paint, oil, etc within at least?

1"

PT- the temperature of penetrant and surface of part shall not be below nor above?

40F to 125F

PT- water washable, what is water pressure and temperature maximum?

Shall not exceed 50psi and 110F

PT- Final interpretation shall be made within?

10 to 60 min

PT- dwell times at temperature between what shall be doubled?

40F to 50F

MT- prod spacing /current shall be?

Direct or rectified shall be used



>= 3/4" thick shall be 100 to 125 amp/ in



< 3/4" thick shall be 90 to 110 amp/in

MT- black light shall be?

1000 uW/cm2 on surface



Verified at least once every 8hrs or when work station is changed.


UT- SE-797 practice provides guidelines for thickness measurement using contact pulse echo method at temperatures not to exceed?

200F

UT- equation to calculate thickness T using UT measurement.

T=Vt/2

RT- from what type of material should shims be fabricated when they are to be used to radiograph welds?

Fabricated of radiographically similar material to the object to be inspected.

VT- three different methods of conducting visual examination?

Translucent, direct, remote visual.