If inadvertantly BITE switch is actuated, what position does the apu/iso valve switch need to be in.

30 sec. After the door open light goes out/after the n2 spools down completely

How soon can a restart be attempted

63+/-2

Normal Control N1 w load bleed valve closed

N2 Always 100+/-1

N2 normal control for all loads

78-91

N1 w load bleed valve open

97

N1 load bleed valve ope , main bfn start

75-100

N1 in standby control all loads

100+/-4

N2 in standby all loads

6 quarts

Do not start APU oil quantity is below

BAT/LOCKED

Battery switch must be in the _____ position prior to APU start

26vdc

Battery voltage must be a minimum...

2.5 quarts

Shut down APU if oil quantity goes below...

1,000, #2

There must be _____ lbs of fuel to start APU in the _____ tank

0-1min on, 5 min off. 4 starts max in 20 min followed by 1 hour cool down

Starter Duty Cycle

4-5

If engine RPM indicator stops rising for any period of _____, terminate start

85

Cockpit windows must be open if temperature exceeds ______ degrees

Place APU GEN switch momentarily to reset

If APU gen OFF light stays on...

Shut down APU immediately

If APU GEN off light stays on after reset...

90seconds-2min

Allow APU to operate w no load for____prior to Shut down

60 seconds

APU using BAT power light goes off ____after APU matter switch is placed in OFF position

OFF, 50% N2 RPM

APU oil pressure lo/temp hi light____ by...

OFF, 95% N2 RPM

APU gen OFF light _____ at....

ON, 95% N2 RPM

APU Power Availbale light____ at...

OFF, 95% RPM

APU using bat power light _____ at...

25%, 25, OFF

If...N2 is not achieved in...seconds place APU in the...position

Run, on, 30

After placing APU to the... position, APU USING BAT POWER should go...in... seconds

45, 60

Acceleration time limit for APU start is... seconds warm... seconds cold.

Immediately place APU MASTER POWER to the OFF position

If APU OIL PRESS LO TEMP HI light does not turn on then turn off between 0-50% N2...

Shut down APU immediately

If APU FUEL PRESS LO light does not go out, or comes on during operation...

Shut down APU immediately

IF APU OIL PRESS LOW TEMP HI light comes on above 95% N2...

Shut down APU immediately

If APU USING BAT POWER light remains on above 95% N2...

Shut down APU immediately

If APU door closes during APU operation...

585 Celsius

APU temp limit is...degrees...