Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
15 Cards in this Set
- Front
- Back
- 3rd side (hint)
Catagory with Draft Hood |
Catagory 1 |
|
|
Catagory where water vapour condenses in the flue gas |
Catagory IV |
|
|
How should joints be fastened for clothes dryer venting? |
Duct tape |
You dont want protrusions to catch lint, fire hazard |
|
Type of furnace that can be serviced but not installed |
Floor Furnace |
|
|
Minimum clearance to combustables from top of counter appliance? |
36" (1m) |
|
|
Type of heater that can be installed on bathrooms? |
Direct vent (7.11) |
|
|
What would constitute permanently opening a fireplace chimney damper? |
Installing certified gas log into wood burning fireplace (7.24) |
|
|
Distance of Swimming pool heater from property line? |
18" (450mm) (7.25) |
|
|
Distance between OUTDOOR swimming pool flue discharge and building opening? |
10' (3m) |
|
|
Minimum clearance from combustibles ro water heater? |
2" (50mm) (7.26) |
|
|
Minimum unprotected clearance from floor to unit heater in garage? |
8' (2.4m) |
|
|
Minimum clearance above a hotplate? |
30" |
|
|
Clearance for gas-fires equipment on all side |
24" |
|
|
Clearance from appliance ignition to garage floor |
18" |
|
|
Distance between gas clothes dryer and regulator vent |
3' (1m) |
|