  • Front
  • Back

Mill tolerance for rolled and welded pipe

-0.010 inches

Maximum allowed length of crack or lack of fusion in new welds

0 inches

Typical flanges face finish

125 to 250 micro inch

When mating flanges, the maximum amount of unparallel allowed (per diameter of flange in feet)

1/16”/ft

Minimum size of fillet weld on socket weld pipe

1/8 inch

Maximum offset for bolt holes for mating flanges (two-hole)

1/8 inch

Maximum allowed size of open discontinuity in a bend test

1/8”

Preheat zone distance from toe of weld

1 inch

PWHT zone-distance from toe of weld

1 inch

Minimum distance beyond the area to be examined to clean a part when performing a PT examination

1 inch

Minimum distance beyond the area to be examined to clean a part when performing a MT examination

1 inch

Minimum radius on patches (both fillet and flush)

1” (8.1.4.2.c/Fig C.2)

Maximum diameter of TML test point for lines less than or equal to10 NPS

2” (3.1.20)

Maximum distance between examiners eye and component during VT exam

24” (V-T-952)

Maximum length of RT when qualifying a welding operator with RT of first production weld

36” (3ft) (IX-QW-305.1)

Minimum length of buried pipe to expose when excavating for inspection

6-8’ (9.3.6)

Maximum size of fillet weld patch on pipe

1/2 diameter (Fig C.2)

Minimum upstream limit of injection point circuit

Greater of: 12” or 3 Dia (5.5.9)

Minimum downstream limit of intensive examination of injection point circuit

10 diameters (5.5.9)

Minimum downstream limit of injection point circuit

Lesser: 1st direction Chg + 25’ or 2nd direction chg

Maximum diameter of TML test point for lines greater than 10 NPS

3” (3.1.20)

Minimum length of spot RT

6” (31.3-344.5.2.c)

Minimum length of RT went qualifying a welder with RT

6” (IX-QW-302.2/304.1)

Distance to dig when inspecting for soil two Dash air corrosion

6” (IX-QW-302.2)

Limits of Soil to-Air area distance in air away from interface

6” (3.1.87)

Distance to dig when inspecting for Soil to-Air corrosion

6”-12” (574-7.4.5)

Limits of Soil-to-Air area distance in soil away from interface

12” (3.1.87)

Minimum upstream limit of intensive examination of injection point circuit

12” (5.5.9)

Minimum overlap when performing PWHT using multiple heats

12” (ft) (31.3-331.2.5)