Min size fresh air intake and duct

-4" diameter


-insulated

Air tight building

-type A



Loose construction

Not airtight AKA type B

Is House is classified as type A or type B?

Type A,


allways air tight

Where does a type A building Get Air Supply from

Require Air Supply from outside for the combustion and flue gas dilution

Where my type B buildings acquire Air Supply from

Outdoors are all the air from indoors

Free area of transfer Grill in type B Building

1sq" for every 1000 Btus of inout

Location of Grill to floor

Min 6"


Max 18" above floor


Where should second opening be placed in a room if the room has a draft Hood Appliance in type B bldg

As close to the ceiling level as possible, but never lower than the lowest draft Hood relief opening and is the same size as the Air Supply opening

Where must fresh air be placed in type A bldg

2 feet horizontally within one foot above the burner level over the appliance with the largest input

Motorized damper installed in a residence must be what?

Certified this does not apply to commercial or industrial applications

The duct exceeds 20 feet to 50 feet the duct will be increased

One size

outdoor Air Supply above grade

Min 12 inch

Opening in an air supply screen door Grill no smaller than

1/4"

How shall any mechanical Air Supply be interlocked with an appliance

So the appliance will not fire if the supply fan fails

Minimum distance of service clearance required for an appliance

Two feet on any side of an appliance that require Servicing

Minimum service clearance required for a boiler

4 ft in front

Swimming pool boiler installed Outdoors clearance from property line

18"

Appliance capable of lighting flammable valour in resi storage garage must be located___ above floor

18"

Appliance capable of lighting flammable vapour in repair garage must be located___ above floor

4-1/2 ft/ 54"

What must a infared tube heater be connected to gas line with, and how long must it be?

Type 1 hose


36" long plus or minus 6"

Min and max length of infared tube heater hose

Min: 30"


Max:42"


Want at 36"

Length of flex connector for a gas range, refrigerator or clothes dryer

6 ft

Suspended appliances are decorative appliances connected to gas line using Flex connector max ___ ft long?

2ft max

Max temp for limit control on forced air furnace

250 degrees Fahrenheit

Max temp for limit control on a gravity furnace

350° Fahrenheit

Category I Appliance

-have draft hood


-fan assist


-certified for install of B vent


-non positive pressure on vent system


-Max 83% effecinet

Catagory II appliance

-non positive vent


-over 83% efficient

Catagory III appliance

-positive vent pressure


-can't use B vent


Use BH vent (usually stainless steel venting)


-3" diameter


-Max combustion 83%


-don't condense


-can still condense in vent however so constructed of non corrosive


-require limestone trap

Catagory IV appliance

-positive vent pressure


-combustion effecency over 83%


-will condesne with water


-Usually 2" s636


-require limestone trap