BVM Bag-Valve-Mask: Reservoir Bag

WARNING! If applicable, ensure proper size reservoir bag is used with each vantilation bag.

BVM Bag-Valve-Mask: pressure limiting device

WARNING! Ensure non-re-breathing valve, with pressure limiting device, is in place on child and infant units.

BVM Bag-Valve-Mask: PEEP

WARNING! needed, the pressure-limiting device can be overridden. Ensure a BVM with a Positive End Expiratory Pressure (PEEP) accompanis intubated patients on ventilators when PEEP is >5 mmHg. PEEP valve is avaliable on the allowance standard.

NPTLOX: Batteries

CAUTION! Use only batteries recommended by NPTLOX Operation and Maintenance Manuel.

NPTLOX: Sliding door

CAUTION! High Vacuum Container Handle with Care. Keep the container assembly sliding door closed at all times when the container assembly is not in use to prevent entry of contamination around the six oxygen outlet quick disconnect receptacles.

NPTLOX: AFI 21-101

WARNING! Per AFI 22-101 , maintenance and filling of LOX system will be done only by qualified LOX personal.

NPTLOX: T.O. 15X2-5-22

WARNING! Per T.O. 15X2-5-22, only personal fully trained and qualified in handling and service liquid oxygen are authorized to service the container assembly.

NPTLOX: Vent

WARNING! Never allow the container assembly to be placed where the vent may be obstructed.

NPTLOX: Gloves

WARNING! Protective gloves (i.e. leather work gloves/nomex flight gloves) are required when lifting the NPTLOX for transport.

NPTLOX: Oil

WARNING! Oil, grease, gasoline, kerosene, and other hydrocarbons are not compatible with oxygen. Spontaneous ignition upon contact of oxygen with these substances may result.

NPTLOX: Control Valve

WARNING! Prior to connecting an oxygen hose to an outlet port,flow control valve, with the control knob set at zero (0), must be attached to the mating hose fitting. This step is imparitive to prvent oxygen from escaping out an open ended hise.

NPTLOX: Inlet/Outlet

WARNING! Always connect the flow control valve fitting marked INLET to the mating fitting on the oxygen hose and the fitting marked OUTLET TO PATIENT to the humidifier bottle or oxygen tuning connector. Reversing these connections or use of a gas source other then specified may result in inaccurate flow rates and patient injury.

NPTLOX: Odors

WARNING! If any odors other then the hose smell are detected, have other personal recheck it for odors. Contact MXS Electrical and Environmental specialists as soon as possible and report the incodent. Do not use this unit! Replace it.

NPTLOX: 10°F

CAUTION! The oxygen flow produced by this device can be within 10 degrees F of ambient temperature. Caution should be exercised if the room temperature is warmer then 90 degrees F.

NPTLOX: Ventilators

WARNING! If two ventilators are used with one NPTLOX, at higher tidal volumes, pressure on the NPTLOX can drop which will not provide adequate flow needed to operate the ventilator.

NPTLOX: 50 FEET

WARNING! Place a minimum of 50 feet from all sparking or flammable devices.

NPTLOX: Petroleum products

WARNING! Never place the system where it will come in contact with petroleum products or hydraulics.

NPTLOX: Ventilated location

WARNING! Operate and maintain the NPTLOX system only in a well ventilated location. Never allow the unit vent port to be obstructed. The vent port must remain open at all times.

NPTLOX: Upright

WARNING! The NPTLOX system should remain upright at all times when filled with LOX to avoid improper operation and excessive venting of oxygen.

NPTLOX: Oxygen lines

WARNING! Do not secure/run lines over moving parts. The Load master or Boom operator will be consulted if oxygen lines are strung outside the litter stanchion area or above the patiant support pallet (PSP).

NPTLOX: Hydraulic reservoirs.

WARNING! Do not position NPTLOX near hydraulic reservoirs.

NPTLOX: Floor.

WARNING! Ensure cargo floor is free of oil or any other petroleum based products.

NPTLOX: Secure

WARNING: (reference: T.O. 15X2-25-22,pg 9). Secure the NPTLOX system in place when used inflight or transported in a ground vehicle.

Portable suction unit: Power Input Jack.

WARNING! Plugging the cord into the external power input jack allowes for external operation and recharging only. In order to operate on battery power, the charger cable must be removed from the external input jack.

MRx Phillips Heartstart

WARNING! When transporting the Heartstart MRx ,it is important to position itwith the display facing away from the body. If not, the therapy Knob may be bumped and inadvertently moved from its current position. Semi-automatic external defibrillator (AED) and 12 lead ECG capabilities are not for in-flight use.