One of the advantages of an SSR over and EMR is its

High resistance to shock longer life higher reliability higher speed switching

One advantage of DC Electric braking is that

Motors can be stopped rapidly without having to use lining or drum

When solid state relays are connected in series The Supply voltage must be

Increase proportionally when connected in series

Which of the following protect the Motor & Control devices against overheating

Solid state protective relays

The voltage unbalance trip point for programmable solid state overload relay is typically set for

5%

Which of the following is a benefit derived from using a post with modulated adjustable frequency drive versus an analog scr afd

Eliminating of dirty power problems harmonic EMR generated by analog scr

The 11 Penn timing Relay can be configured for single shot order

Delay on break

What is another name given to a solid state reduced voltage starters because of their ability to provide a smoothie Step less start and acceleration

Soft start controller

When does an off delay relay provide the same time delay

After the relay is De- energized

Dynamic motor braking is often used with AC Motors being controlled by

AFDs

Which of the following solid state relay switching modes are typically used to control heavy inductive loads

Peak switching

Which of the following characteristics are an advantage for using Electro mechanical relays vs. A solid state relay

Effects of temperature AC/DC switching with the same contacts

When troubleshooting a motor the possible causes for chatter is

Broken pole Shader, contactors control circuit, low voltage

In a typical DC Electric braking circuit power supply to the braking relay by a

NOTO contact

SSOLR initiates a trip if the phase current exceed what percentage of the trip current dial settings

125%

A small unbalanced and phase to phase voltage can result

Mike Schrader current imbalance

Most Nema rated general purpose motors have an overcurrent trip class rating of

20

Which type of braking system engages solenoid operated friction brakes

Electromechanical braking