An Act To Enhance the Mobility of Disabled Persons
by Requiring Certain Buildings, Institutions, Establishments and Public
Utilities to Install Facilities and Other Devices

Batas Pambansa Bilang 344


Building and related structures to be constructed



Government owned living Accommodations = % shall be accessible & fully usable by the disabled persons

10 %

Building and related structures to be repaired or renovated including those proposed for a change of occupancy.


 


When facilities is accessible by means of an elevator with a minimum width of

800 mm


Streets, highways and transport related structures to be constructed



Public Telephones


at least 1 unit for every ( ) units shall be accessible to disabled person

4 Units

Rule II Minimum Requirements for Accessibility


Design Criteria




Basic Physical Planning Requirements


Accessibility


Reachability


Usability


Orientation


Safety


Workability and Efficiency

An Act To Enhance the Mobility of Disabled Persons
by Requiring Certain Buildings, Institutions, Establishments and Public
Utilities to Install Facilities and Other Devices

Accessibility

Provisions shall be adapted and introduced to the physical environment so that as many places or buildings as possible can be reached by all

Reachability

The built environment shall be designed so that all persons, whether they be disable or not, may use and enjoy it

Usability

Finding a person's way inside and outside of a building or open space shall be made easy for everyone

Orientation

Designing for safety insures that people shall be able to move about with less hazard to life and health

Safety

The built environment shall be designed to allow the disable citizens to participate and contribute to development goals

Workability and Efficiency

Rule III Specific Requirements for Building & Related Structures for Public Use



Building Classification as per NBC PD 1096



Category 1 is

Residential

Rule III Specific Requirements for Building & Related Structures for Public Use



Building Classification as per NBC PD 1096



Category II is


 


Commercial & Industrial

Rule III Specific Requirements for Building & Related Structures for Public Use



Building Classification as per NBC PD 1096



Category III is

Educational & Industrial

Rule III Specific Requirements for Building & Related Structures for Public Use



Building Classification as per NBC PD 1096



Category IV is

Agricultural

Rule III Specific Requirements for Building & Related Structures for Public Use



Building Classification as per NBC PD 1096



Category V is

Ancillary

Rule III Specific Requirements for Building & Related Structures for Public Use




Architectural Features & Facilities




A – Stairs


B – Walkways


C – Corridors


D – Doors and Entrance


E – Washrooms and Toilets


F – Lifts/Elevator


G – Ramps


H – Parking Areases, Controls, Buzzers


J – Handrails


K – Thresholds


L – Floor Finishes


M – Drinking Fountains


N – Public Telephones


O – Seating Accommodations


Rule III Specific Requirements for Building & Related Structures for Public Use



for Auditoriums, Assembly Halls, Theaters & related facilities



when seating capacity exceeds 500 = additional wheelchair seating space shall be provided for each total seating capacity increase of

100 seats

Rule V Administration & Enforcement



Criminal Liability



As stipulated in Section 46 of R.A. 7277, otherwise known as the

Magna Carta for Disabled Persons

Rule V Administration & Enforcement



Criminal Liability



1st Violation =


Php 50,000 but not exceed 100,000 imprisonment not less than 6 months but not more than\ 2 years or both

Rule V Administration & Enforcement



Criminal Liability



Subsequent violation =


Php 100,000.00 but not exceed Php 200,000.00 imprisonment for not less than (2) years not more than (6) years, or both at the discretion of the court

Design & Criteria



Categories Of Disabled Persons


Confinement to Wheelchair


Difficulty in Walking


Total Impairment of Sight


Total Impairment of Hearing


Total impairment due to Aging


Mental Impairment



Design & Criteria


 


Anthropometrics and Dimentional data 


 


Wheel Chair Dimension:


 

Design & Criteria



Anthropometrics and Dimentional data



Wheel Chair Dimension:


Length = 1.10 to 1.30 m



Front Width = 0.45 to 0.55 m



Rear Width = 0.60 to 0.75 m



Turning Space =2.25 sqm or 1.50 x 150 m

Design & Criteria



Anthropometrics and Dimentional data



Wheel chair reach 0.70 to 1.20m above floor and not less than


 


0.40 m from room corners

Design & Criteria



Anthropometrics and Dimentional data



Wheel chair clear space under table

0.70 m

Design & Criteria



Fencing for roadworks & Footworks


 


railing should incorporate a tapping rail to assist the blind = not be greater than



0.35 m above adjacent surface

Fencing for roadworks & Footworks



The height of the top of the rail should be at least

1.00 m bove the adjacent surface

Minimum requirement for Accesibility


 


Covers for Excavations


 


Sides should be ramped if projecting more than

Covers for Excavations


 


Sides should be ramped if projecting more than

25 mm

Minimum requirement for Accesibility


 


Covers for Excavations


 


If the footway width will be reduced to less than (    ) because of excavation, temporary covering should extend across the whole of the footway.

Covers for Excavations



If the footway width will be reduced to less than ( ) because of excavation, temporary covering should extend across the whole of the footway

1.20 m

Minimum requirement for Accesibility


 


Minimum dimension @ Obstructions


 


Effective width of footways = no less than

Minimum dimension @ Obstructions



Effective width of footways = no less than

1.20 m


1.50 m preffered

Minimum requirement for Accesibility


 


Minimum dimension @ Obstructions


 


If avoidable, loose materials temporarily stored on footways must be properly fenced & prevented from encroaching onto the main footway by the use of kickb...

Minimum dimension @ Obstructions



If avoidable, loose materials temporarily stored on footways must be properly fenced & prevented from encroaching onto the main footway by the use of kickboard ( ) which also serve as a tapping board for the blind




at least 0.20 m high

Minimum requirement for Accesibility


 


Signage for roadworks on the carriageway


 


Signs should not reduce the available walkway width to less than

Signage for roadworks on the carriageway


 


Signs should not reduce the available walkway width to less than

1.20 m

Rest stops at busy or lengthy walkways



In lengthy or busy walkways, spaces should be provided at some point along the route so that the wheelchair may pass another or turn around.


Spaces should be in min dimension ( ) & should be spaced @ a maximum of





1.50 x 150m


12.00m between stops

1.50 x 150 m


12.00 m between stops

Minimum requirement for Accesibility


 


Walkway headroom should not be less than 


 

Walkway headroom should not be less than


2.0 m and preferably higher

Minimum requirement for Accesibility


 


Dropped Curbs


 


Minimum width is

Dropped Curbs



Minimum width is

0.90 m

Minimum requirement for Accesibility


 


Dropped Curbs


 


Shall be ramped towards adjoining curbs with gradient not more than


Dropped Curbs



Shall be ramped towards adjoining curbs with gradient not more than

1:12

Minimum requirement for Accesibility


 


Dropped Curbs


 


Shall be sloped towards the road with max. cross gradient of

Dropped Curbs



Shall be sloped towards the road with maximum cross gradient of

1:20

Dropped Curbs



Lowest point should not exceed ( ) from the road or gutter


25 mm

Variation of dropped curb at corner


 


Minimum width is

Variation of dropped curb at corner



Minimum width is

0.90 m

Curb cut-outs


 


Minimum width is

Curb cut-outs



Minimum width is

0.90 m

Signage


 


sign protrude into a walkway or route with a minimum headroom of

Signage



sign protrude into a walkway or route with a minimum headroom of

2.00 m

Signage


 


raised symbols, letters or numbers with minimum height of

Signage


 


raised symbols, letters or numbers with minimum height of

1 mm

Signage



Signs on walls and doors should be located at



a maximum height of


a minimum height of

1.60 m maximum and 1.40 m minimum


Parking


 


Min. width of 


 


Walkway from accessible spaces is

Parking



Minimum width of



Walkway from accessible spaces is

3.70 m and 1.20 m clear width

Ramp


 


minimum clear width of 

Ramp



minimum clear width of

1.20 m

Ramp


 


length of a ramp should not exceed 

Ramp


 


length of a ramp should not exceed

6.00 m if the gradient is 1:12

Ramp



maximum gradient shall be

1:12

Ramp


 


longer ramps whose gradient is 1:12 shall be provided with landings not less than

Ramp


 


longer ramps whose gradient is 1:12 shall be provided with landings not less than

1.50 m

Ramp


 


Level area at top and bottom of any ramp

Ramp


 


Level area at top and bottom of any ramp

1.80 m

Ramp


 


Provide handrails on both sides

Ramp



Provide handrails on both sides

0.70 x 0.90 m height

Ramp


 


Any ramp with a rise greater than 0.20 m. and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not less than

Ramp



Any ramp with a rise greater than 0.20 m and leads down towards an area where vehicular traffic is possible, should have a railing across the full width of its lower end, not less than

1.80 m from the foot of the ramp

Ramp


 


Entrances with vestibules


 


Shall be provided a level area with at least

Ramp



Entrances with vestibules



Shall be provided a level area with at least

1.50 m width and 1.80 depth

Doors


 


operable by pressure or force not more than 4 kg; closing device pressure an interior door shall not exceed 1 kg

Doors



operable by pressure or force not more than 4 kg; closing device pressure an interior door shall not exceed 1 kg

0.80 m minimum clear width

 


 


Min. Clear level space (   ) before & extending beyond a door


 


Min. Clear level space ( ) before & extending beyond a door

1.50 x 1.50 m

Door


 


Where a door shall open onto but not into a corridor, the required clear level space on the corridor side of the door may be a minimum of 

Door



Where a door shall open onto but not into a corridor, the required clear level space on the corridor side of the door may be a minimum of

1.20 m corridor width

Door


 


Door knob latches height


 


Kick plate

Door



Door knob latches height



Kick plate


0.82 m to 1.06 m ( 0.90 m Preferred)



0.30 m to 0.40 m

Door


 


Switch height

Door



Switch height


0.92 m to 1.22 m from FFL



0.20 m maximum from latch of the door

Stairs



A tactile strip ( ) wide shall be installed before hazardous areas such as sudden changes in floor levels and at the top & bottom of stairs; special care must be taken to ensure the proper mounting or adhesion of tactile strip so as not to cause accidents

0.30 m

Elevators


 


Accessible elevators should be located not more than (  )  from entrance & easy to locate by the aid of signs

Elevators


 


Accessible elevators should be located not more than ( ) from entrance & easy to locate by the aid of signs

30.00 m

Elevators



Minimum door opening

0.80 m

Elevators



 


Minimum car dimension of

1.10 x 1.40 m

Elevators



Minimum shaft dimension of

1.50 x 1.80 m

Elevators


 


Button sizes minimum diameter of


 

Elevators



Button sizes minimum diameter of


20 mm and depression of 1 mm

Elevators


 


Control Panel & Emergency system top most button

Elevators



Control Panel & Emergency system top most button

0.90 to 1.20 m from floor

Corridor


 


also provided at or within (  )  of every dead end

Corridor



also provided at or within ( ) of every dead end


3.50 m


Signage


 


Signage for Men’s washroom door equilateral triangle w/ vertex pointing upward


 


Signage for Women’s washroom door circles


 


Edges of the triangle and diameter of circle 


 

Signage



Signage for Men’s washroom door equilateral triangle w/ vertex pointing upward


 


Signage for Women’s washroom door circles



Edges of the triangle and diameter of circle


0.30 m long with atleast 7.5 mm thick

Lavatory



Maximum height of ( ) with knee recess of ( ) vertical clearance & ( ) depth

0.80 m height


0.60 to 0.70 m vertical


0.50 m depth


Urinal


 


Should have an elongated lip or through type the maximum height of the lip should be 

Urinal



Should have an elongated lip or through type the maximum height of the lip should be

0.48 m

Urinal


 


Grab bar should be provided both sides at

Urinal



Grab bar should be provided both sides at

0.60 m

Water Closet


 


Minimum dimension of

Water Closet



Minimum dimension of

1.70 x 1.80 m

Water Closet


 


Maximum height of


 


Maximum height of flush control

Water Closet



Maximum height of



Maximum height of flush control

0.45 m



1.20 m

Public Telephone



Telephone booth door openings minimum clear width of ( ) with either outswing, folding or sliding doors, coin slots, dialing controls, receivers & instructional signs shall be locked at a maximum ( ) above floor


0.80 m and 1.10 m

Definition



refers to features that enable disabled persons to make use of the primary functions for which a structure is built

Accessible

Definition



pertaining to the measurement of the human body

Anthropometric

Definition



unhindered, without obstructions to enable disabled persons free passage or use of the facilities.


Barrier Free

Definition



a raised rim of concrete, stone or metal which forms the edge of street, sidewalk, planted area, etc

Curb

Definition



a break in the sidewalk or traffic island provided with an inclined surface to facilitate mobility of wheeled chairs, carriages and other similar conveyance.

Curb Cut Out

Definition



those suffering from restriction or lack of ability to perform an activity in the manner or within the range considered normal for a human being as a result of a mental, physical or sensory impairment

Disabled Persons

Definition



the degree of inclination of a sloped surface expressed as a percentage or ratio


Gradient of Ramp

Definition



a drawing, painting, diagram, engraving, etching or other similar illustrations on which a single glance conveys a given message; a visual aid

Graphic Sign

Definition



distance between two points aligned vertically with one of the points on the floor

Height Above Floor

Definition



allocated space composed of marked-off portions for single motor vehicles on a short-time storage basis

Parking Area

Definition



a space connecting one area or room of a building with another

Passageway or Passage

Definition



sloped surface connecting two or more planes at different levels

Ramp

Definition



strip fastened to the floor beneath a door, usually required to cover the joint where two types of floor materials meet; may provide weather protection at exterior doors

Threshold

Definition



small entranceway or transitional space from the exterior to the interior of a building and opens into a larger space

Vestibule

Definition



a fixture consisting of a shallow basin, together with a water jet designed to provide potable water for human consumption

Water Fountain

Definition



the linear width of the obstructed path in corridors

Width of Corridor

Section 4



Any person violating any provision of this Act or of the rules and regulations
promulgated hereunder shall, upon conviction by a court of competent jurisdiction,
suffer the penalty of imprisonment of not less than one month but not more than one
year or a fine of

P2,000 to P5,000 or both