Calculating Area

A=π r2

Calculating Volume

V=AH (area x height)

What minimum precautions must be taken before attempting to reset a plunger gripper?

Assure the system can maintain static no-load pressure

Because of the danger of failure in the early single bottom hydraulic jacks, what is now required?

Adding a safety bulkhead at the bottom of the cylinder

How often must a static load test be performed?

Every year

What is another term for up slow down?

Up transition

What describes the operation of a typical hydraulic block valve with an elevator landed at the floor?

The down valve is closed, the check valve is closed, and the up valve is open

How are larger motors usually started?

Reduced current starting

What is another term for schedule 80 pipe?

Extra strong wall pipe

What is the maximum speed of a residential elevator?

40 ft/min

What is required of the installer when the hoistway openings of an installation and not secured from the general public?

Completely closed off hoistway openings.

Rack and pinion pit structures consist of which components?

Foundation, base enclosure, buffer springs

Where are safety hooks mounted?

They are mounted to the frame below the lowest pinion

A minimum of two back up rollers on the machinery plate is required on which kind of hoist?

Rack and pinion hoists

Back up rollers are to be made of which material?

Metal

Which component maintains proper rack-to-pinion engagement?

Back up rollers

A rack and pinion motor brake is spring set and _______ released

Electrically released

Which code do most issues regarding the installation of temporary hoists fall under?

ANSI A10.4

What is a requirement for the cage of a temporary R&P hoist?

It uses electrical switches to determine gates are closed.

What is the purpose of the centrifigal brake?

To prevent overspeeding of the car during manual release of the motor brake.

What would cause failure of the friction discs to work properly in a safety device?

Over lubrication of the grease fitting

Which safety device is required on a swivel seat?

Cut-off switch if seat is not locked

What is the maximum capacity of an inclined platform lift?

750 lbs

Obstruction sensors on an inclined platform lift are located in which area?

Under the platform and on edges facing direction of travel

What is used to maintain proper tension on a step chain?

Lower carriage

What applies to the proper use of anti slide devices?

Must be no more than 3/4 inch high

What is the maximum allowable distance between skirt panels and the adjacent step tread?

3/16"

Which switch requires manual reset after actuation?

Step level switch

How are larger motors usually started?

Reduced current starting

What authority says that the machine must be visible from the main line disconnect switch?

National electrical code

How would you describe a one-man pressure relief valve test?

A single mechanic operates the pump from outside the machine room and record relief pressure

What are the most common voltage and current requirements for vertical platform lifts?

120 V, 20 amp

How many inches thick and what PSI rating should the concrete base be constructed for on a vertical platform lift?

4 in thick and 3500 PSI

Landing entrance doors to a vertical platform lift cannot be opened unless.....?

Within 2" of the landing

What is the maximum rated speed for a platform lift?

30 fpm

What is the minimum rated load of a vertical platform lift?

450 lbs

What is the maximum rated load for a platform lift?

750 lbs

Which drive system is capable of greater speeds than the powered ball screw?

Hydraulic drive system

How do you determine the "hand" of a platform lift?

Face the unit at the bottom landing. If the mast or machine tower is on the left than the unit is a "left-hand unit"

The running clearance around the sides of the platform floor is to be between??

3/8" and 3/4"

The top final limit switch is set to stop the platform after it travels past the normal stopping device and before??

Before striking an obstruction

Final terminal stopping devices are not required for direct plunger or???

Or roped hydraulic driving machines

(true or false). LULA and residential lifts having the same equipment, use identical sections of governing codes

False

What is the recommended interval for routine periodic inspections for LULA and residential installations?

Six months LULA, 1-year residential

What annual test is required for hydraulic driven LULA and residential lift equipment if the cylinder is not exposed?

15 minute leak test with no load

What annual test is required for governor operated safeties on LULA and residential lift equipment?

Tripping the governor at the slowest speed possible with no load

At five-year intervals, governor's should be tested and tagged for tripping speed, pull through force and ??

And safety switch operation

Which two functions are combined into a single valve?

Upstart bypass and relief valve

In order to take advantage of wye Delta starting for a pump unit what is required?

Two line starters

What is a special requirement for hydraulic elevator systems that use a flexible line installed in high-pressure portions of the system?

Replacement at six-year intervals

How much clearance must be maintained between the skirt panels and the pallet edge on a walkway with a skirted balustrade?

1/4 in.

How much side-to-side movement is allowed on a belted moving walkway

3/8 in.

What is the maximum allowable gap between interior panels

3/16 in.

How are safeties applied on a rack and pinion driven inclined stairway platform lift

Safety governor is used

On a vertical platform lift, the stop button must be located at what height above the platform floor?

Between 15 and 48 in.

When there is leakage that cannot be accounted for on a hydraulic elevator, what kind of test is performed?

A pressure test of the unexposed hydraulic line and cylinder

How many cm are in one inch? Mm?

2.54 cm 25.4 mm

One mm equals how many inches?

.03937"

Using current from a rectifier, through an anode, then to the cylinder describes what type of corrosion protection system?

Impressed current system

During hydraulic pump motor starting, what is true?

Line current is high

What does the upper truss section of an escalator generally contain?

The drive machine and upper drive sprocket or bull gear. It also contains the main line disconnect switch, the controller and all other necessary junction boxes

An escalator brake must be capable of stopping a down running escalator at a rate no greater than?

3 ft/sec2

Which escalator brake system would use hydraulics to retract the pads?

Caliper brake

The lower carriage and sprocket is sometimes referred to as??

Tension carriage or reversing station

When the steps are on the transition boards, it keeps the rollers off The track by??

.010 - .015 in.

Which track is the bottommost track of the four tracks?

Lower chain track.

What is the purpose of the lower carriage?

It provides the proper amount of tension for the step chain axles to travel properly through the escalator truss.

On a 4-track system, the uppermost track carries the?

Step chain axle rollers

The transition board is used to minimize the load on?

The step wheels during the turnaround

Minimum depth requirement for a step cannot be less than?

15 3/4 in.

The rise between treads should not exceed??

8 1/2 in.

What is the maximum depth and width of slots on cleated step treads?

No more than 1/4 inch wide and no less than 3/8 inch deep

Step width is restricted to?

22 and 40 inches

How many tracks are found on moving walks?

2

What is the minimum step width of a moving walkway?

22"

At what distance must have required permanent mechanical holding device stop and hold a LULA elevator above the pit floor?

35 to 79 in.

In a situation where a standard pit is provided for a LULA elevator and when no hoistway enclosure is provided at the lower level, how high of an enclosure must be around the pit?

84"

What is the maximum speed at which a governor (if provided) on a LULA or residential installation is permitted to trip?

75 ft per minute

Overspeed valves will stop a downward traveling LULA elevator if it exceeds rated speed by what amount?

110 to 140%

What type of LULA elevator is not required to be in an enclosed hoistway, provided that there is a means to stop down running car if an obstruction exists below the car?

Private residence elevator

When using wire rope, the diameter of the sheave must be how many times the diameter of the suspension ropes?

30

In a private residence elevator, what is the term for the 2 x 10 plank that is doubled up to serve as the anchor for the rail brackets?

Pillar

The hoistway doors for a LULA elevator have which of the following distinct variations to passenger elevator code?

A powered swing-door is permitted

What is the maximum allowable rated load for a LULA elevator

1400 lbs.

What is the maximum speed of a residential elevator?

40 ft/min

For belted walkways, tension is normally maintained at approximately???

3000 lbs

The drive end of a belted walkway is called?

The Head end