Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
73 Cards in this Set
- Front
- Back
Max Continuous Ng |
99% |
|
Intermediate Ng |
102% |
|
Transient Ng (12 Seconds) |
105% |
|
Np No limit |
110% |
|
Np transient (12 Seconds) |
127% |
|
Max contiguous TGT. |
1490 °F |
|
Intermediate TGT (30 Minutes) |
1564 °F |
|
Max TGT (10 mins) |
1612 °F |
|
Contingency TGT (2.5 Minutes) |
1657 °F |
|
Transient TGT (12 Seconds) |
1740 °F |
|
Starting TGT |
1564 °F |
|
Operating time limit up to 1490°F TGT |
No time limit. |
|
Temp time limit at 1564°F TGT |
30 Minutes |
|
Time limit at 1612°F TGT |
10 Minutes |
|
Time limit at 1612°F TGT |
10 Minutes |
|
Time limit at 1657°F TGT |
2.5 Minutes |
|
Time limit at 1740°F TGT |
12 Seconds |
|
Time limit at 1740°F TGT |
12 Seconds |
|
Operation time limit above 1740° TGT |
No operation allowed |
|
Max continuous tq |
500 ft/lbs |
|
Max continuous tq |
500 ft/lbs |
|
Intermediate output tq |
543 ft/lbs |
|
Transient tq (12seconds) |
700 ft/lbs |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
HMU vent drain leak RUNNING |
50 CC’s/Hr |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
HMU vent drain leak RUNNING |
50 CC’s/Hr |
|
HMU vent drain leak STATIC (except when priming) |
50 CC’s/hr |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
HMU vent drain leak RUNNING |
50 CC’s/Hr |
|
HMU vent drain leak STATIC (except when priming) |
50 CC’s/hr |
|
Oil Cooler leakage rate |
No leaks allowed |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
HMU vent drain leak RUNNING |
50 CC’s/Hr |
|
HMU vent drain leak STATIC (except when priming) |
50 CC’s/hr |
|
Oil Cooler leakage rate |
No leaks allowed |
|
ODV drain at shutdown |
100 CC max / 15 CC min |
|
Free Air Temp (FAT) |
-65°F to 135°F |
|
Fuel and oil leakage rate |
2cc’s or 10 drops per min |
|
HMU vent drain leak RUNNING |
50 CC’s/Hr |
|
HMU vent drain leak STATIC (except when priming) |
50 CC’s/hr |
|
Oil Cooler leakage rate |
No leaks allowed |
|
ODV drain at shutdown |
100 CC max / 15 CC min |
|
All drain leak limit on false start |
200 cc max |
|
Igniter Duty Cycle |
2 on 3 off 2 on 3 off 2 on 48 off (Minutes) |
|
Time between ground starts |
30 seconds |
|
Time to idle |
30 seconds |
|
Time to light off |
10 Sec or 30 sec on first start |
|
Oil pressure flux |
+/- 5psi max |
|
Oil consumption |
133 cc/hr (1qt per 6.5hr) |
|
Normal and Max Oil Temp |
Norm: 95-275°F Max. : 300°F |
|
Start vibe limit |
2.8 ips |
|
Start vibe limit |
2.8 ips |
|
Transient vibes less than 5 Sec |
2.8 Ips |
|
Start vibe limit |
2.8 ips |
|
Transient vibes less than 5 Sec |
2.8 Ips |
|
Steady state vibrations |
1.5 ips |
|
Start vibe limit |
2.8 ips |
|
Transient vibes less than 5 Sec |
2.8 Ips |
|
Steady state vibrations |
1.5 ips |
|
Air Dynamometer vibes |
2 mild peak to peak max |
|
Start vibe limit |
2.8 ips |
|
Transient vibes less than 5 Sec |
2.8 Ips |
|
Steady state vibrations |
1.5 ips |
|
Air Dynamometer vibes |
2 mild peak to peak max |
|
All power settings vibe limit |
2.0 ips |