• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/73

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

73 Cards in this Set

  • Front
  • Back

Max Continuous Ng

99%

Intermediate Ng

102%

Transient Ng (12 Seconds)

105%

Np No limit

110%

Np transient (12 Seconds)

127%

Max contiguous TGT.

1490 °F

Intermediate TGT (30 Minutes)

1564 °F

Max TGT (10 mins)

1612 °F

Contingency TGT (2.5 Minutes)

1657 °F

Transient TGT (12 Seconds)

1740 °F

Starting TGT

1564 °F

Operating time limit up to 1490°F TGT

No time limit.

Temp time limit at 1564°F TGT

30 Minutes

Time limit at 1612°F TGT

10 Minutes

Time limit at 1612°F TGT

10 Minutes

Time limit at 1657°F TGT

2.5 Minutes

Time limit at 1740°F TGT

12 Seconds

Time limit at 1740°F TGT

12 Seconds

Operation time limit above 1740° TGT

No operation allowed

Max continuous tq

500 ft/lbs

Max continuous tq

500 ft/lbs

Intermediate output tq

543 ft/lbs

Transient tq (12seconds)

700 ft/lbs

Free Air Temp (FAT)

-65°F to 135°F

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

HMU vent drain leak RUNNING

50 CC’s/Hr

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

HMU vent drain leak RUNNING

50 CC’s/Hr

HMU vent drain leak STATIC (except when priming)

50 CC’s/hr

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

HMU vent drain leak RUNNING

50 CC’s/Hr

HMU vent drain leak STATIC (except when priming)

50 CC’s/hr

Oil Cooler leakage rate

No leaks allowed

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

HMU vent drain leak RUNNING

50 CC’s/Hr

HMU vent drain leak STATIC (except when priming)

50 CC’s/hr

Oil Cooler leakage rate

No leaks allowed

ODV drain at shutdown

100 CC max / 15 CC min

Free Air Temp (FAT)

-65°F to 135°F

Fuel and oil leakage rate

2cc’s or 10 drops per min

HMU vent drain leak RUNNING

50 CC’s/Hr

HMU vent drain leak STATIC (except when priming)

50 CC’s/hr

Oil Cooler leakage rate

No leaks allowed

ODV drain at shutdown

100 CC max / 15 CC min

All drain leak limit on false start

200 cc max

Igniter Duty Cycle

2 on 3 off


2 on 3 off


2 on 48 off


(Minutes)

Time between ground starts

30 seconds

Time to idle

30 seconds

Time to light off

10 Sec or 30 sec on first start

Oil pressure flux

+/- 5psi max

Oil consumption

133 cc/hr (1qt per 6.5hr)

Normal and Max Oil Temp

Norm: 95-275°F


Max. : 300°F

Start vibe limit

2.8 ips

Start vibe limit

2.8 ips

Transient vibes less than 5 Sec

2.8 Ips

Start vibe limit

2.8 ips

Transient vibes less than 5 Sec

2.8 Ips

Steady state vibrations

1.5 ips

Start vibe limit

2.8 ips

Transient vibes less than 5 Sec

2.8 Ips

Steady state vibrations

1.5 ips

Air Dynamometer vibes

2 mild peak to peak max

Start vibe limit

2.8 ips

Transient vibes less than 5 Sec

2.8 Ips

Steady state vibrations

1.5 ips

Air Dynamometer vibes

2 mild peak to peak max

All power settings vibe limit

2.0 ips