Voltage measurement is taken |
Parallel and power on |
|
Amperage measurement is taken |
Series & power on |
|
Ohms measurement taken |
Parallel & power off |
|
Never connect ammeter to a circuit that is connected in |
Parallel to the load |
|
If a voltage across contacts reads “0” then the contacts are |
Closed |
|
List 3 devices needed for a circuit |
Power source Switch Load (appliance) |
|
An operating control does this |
Starts and stops equipment |
|
Primary controls do this |
Activate directly by operating control |
|
The 3 variations of a schematic are |
Line Ladder Pictorial |
|
A relay is a device that________ And ________ a set of electrical contacts and is activated by a _____ |
Opens and closes Coil |
|
A contactor works the same way as a relay but is |
Larger |
|
A time delay relay does what |
Delays the start time of a load |
|
A low limit is a NC contact activated by |
A temperature sensing device |
|
An end switch is used to |
Verify a mechanical action has taken place |
|
A flame safeguard system is |
An electronic system that sequences and supervises burner operation |
|
An ignition transformer is |
A step up transformer used to safely ignite a pilot or main burner by direct spark |
|
Main gas valve is piped in _______ and wired in _______ |
Series Parallel |
|
An amplifier is a solid state device that |
Takes AC current and changes it to DC |
|
Low and high level air switches are used to |
Measure the required air movement through the appliance by measuring a predetermined pressure drop |
|
Electrical formulas E = ? I = ? R = ? W = ? |
Volts Amps Resistance Watts |
|
Ohms law is |
E = I x R or R = E/I and I = E/R |
|
Watts (power) law is |
W = I x E or P = I x E |
|
How many loads are there in a series circuit? |
One |
|
Series circuit resistance ROT |
The sum of ALL resisters will always be greater than the largest resister in he system |
|
Parallel circuit ROT |
the sum of all resisters will always be LESS than the value of the smallest resister in the system |
|
Series circuit formula is |
Rt = R1 + R2 + R3 |
|
Parallel circuit formula is |
1/Rt = 1/R1 + 1/R2 + 1/R3 |
|
Series/parallel ROT |
first calculate resistance of parallel circuit and then add the series portion |
|
Series/parallel formula |
1/Rt = 1/R2 + 1/R3 |
|
VA formula |
VA = V x A |
|
A heat anticipator is designed to prevent |
System lag and temperature overshoot |
|
What gauge wire is used to wire a thermostat |
18 AWG |
|
What do the tsat terminal block labels R W G Y C mean |
Power Heating Fan Cooling Common |
|
Limit and safety switches are normally _______ switches |
Closed |
|
Flow switches and low water cutoff controls are normally _______ switches |
Open |
|
Limits and safety switches are wired in ________ with the primary control |
Series |
|
A solenoid valve must be upstream or downstream of the 100% shut off valve and the appliance regulator |
Downstream |
|
What is the maximum high limit setting for a forced air conversion furnace |
250F (120C) |
|
What is this symbol |
Single pole single throw switch |
|
What is this symbol |
Fuse |
|
What is this symbol |
Single pole dbl throw |
|
What is this symbol |
Normally open pressure |
|
What is this |
Normally closed pressure |
|
What is this |
Normally open liquid level switch |
|
What is this |
Normally closed liquid level switch |
|
What is this |
Normally open tstat |
|
What is this |
Normally open fan switch |
|
What is this |
NC high limit |
|
Front (Term) |
NO contact |
|
Front (Term) |
NC contact |
|
Front (Term) |
Magnetic coil |
|
Front (Term) |
Solenoid gas valve |
|
Front (Term) |
Motor |
|
What is this |
Low water cutoff |
|
Front (Term) |
Fixed resister |
|
Front (Term) |
Variable resister |
|
Front (Term) |
Transformer |