  • Front
  • Back

HPU delivers how many gallons per minute at how many psig?1

50 GPM at 1,500 PSIGWH

When this switch is in the AUTO position the cooling pump motor starts and stops in response to?

Fluid temperature in the sump tank

Hydraulic cool pump starts and stops at?

Starts: 120 degree F


Stops: 110 degrees F

The hydraulic oil cooler pump is set to start when the oil temp rises to?

130 degrees F

Normal accumulator nitrogen precharge pressure?

1,125 PSIG

Normal main pump discharge pressure?

1,500 PSIG

The HP relief valve will open, and differential pressure cutout switch will stop the main pump when system pressure exceeds?

1,650 PSIG

While aligning the HPU ensure hydraulic temps is between

60 degrees and 150 degrees F

HPU operating parameters

Min: 200 PSIG


Max: 1,500 PSIG


Temps: 60 and 150 degrees F