  • Back

What size traps can a 1 1/4" vent pipe vent?
1 1/2"?
2"?

1 1/4" Vent = 1 1/4" & 1 1/2" Trap


1 1/2" Vent = 2", 3", 4" Trap


2" Vent = +5" Trap

The maximum distance between the vent and the trap is measure from the _______ to the _______

Trap weir
vent pipe fitting

What is the maximum allowable drop on a horizontal drain and the vent pipe connection?

The diameter of the trap arm

What is the minimum distance between the vent and the trap?

Twice the diameter of the trap arm

What is the maximum allowable vertical distance between the fixture and the trap by Canadian code? By Alberta amendment?

Canadian code - 48" (1200mm)


Alberta Amendment - 36" (900mm)

What is a fixture drain now called if it drains through one complete story

Waste or Soil Stack, depends what it is draining

A flat vent is a trade name for what kind of vent?

It requires a cleanout

Why is the continuous waste and vent principle connection considered the best arrangement for venting?

Because waste water doesn't enter the vent pipe

If your trap is self-siphoning, why might that be happening?

Trap is too far below the fixture

Why would you have to put a 3" stack vent in a residence even though you could put in a smaller stack vent due to low hydralic loads

Because the National Plumbing Code of Canada says it requires it

What is the minimum size trap for a lavatory?
kitchen sink?
shower/tub?


toilet?
lanudry trap?
lanudry stand pipe?

1 1/4" trap - Lavatory
1 1/2" trap - Kitchen sink, shower, tub,
2" trap - lanudry stand pipe


3" trap - toilet

Why should the vent pipe roof flashing be compartible with the vent pipe?

To avoid electro-chemical corrosion

What is the primary function of a trap?

To keep sewer gas from entering into a building

What is the minimum trap seal depth?

1 1/2"

What is the minimum size trap if it serves two lavatories

1 1/2"

What would happen if the fall on a trap arm was more than one pipe diameter?

Self-siphoning

If your fixture has trap seal blowouts, what problem is occuring?

Back pressure is forcing the trap water back up the fixture outlet pipe, due to partial blockage of the drain