Nt1310 Unit 4 Lab Report

Improved Essays
b. When measuring the resistance value with the Avo 8, possible reasons for varience include a parallax error (not looking at the reading from directly above the meter), a reading error due to less divisions when measuring resistance, or the device not being properly zeroed. When measuring current, there are also fewer division, parallax is still a potential issue, and finally, incorrect zeroing of the meter. Voltage has an additional error, the loading of the meter itself. Alongside this issue, there is also parallax, zero, and accuracy/divisions.
With the DMM220, there are fewer errors. It displays up to 4 digits, is accurate within .3% and is auto ranging. There will be minimal effect by loading when measuring voltage.

c.The value measured for
…show more content…
With a sesnsitivity of 20kΩ/V and using the 10V range, it has a resistance of 200kΩ. This changes the resistance being measured, causing a change in voltage. Doing a meter loading calculation (calculated-measured)/calculated gives a loading of 8.7%. Doing the same calculation for the digital meter (which has a much higer sensitivity) gives 0.4% loading, significantly less.

dTo measure voltage, it is clear that the DMM2200 was more suitable than the Avo8 due to the meter loading. A higher meter loading percentage will increase the variance from the true answer, meaning the lower value of the digital meter is desirable.
When measuring current, a lower resistance is ideal. It would seem, then, that the analogue meter would perform better, but the digital meter won out once again due to the difficulty of reading the scale on the analogue. Ease of operation is worth considering when selecting a multimeter.
Finally, when measuring resistance it is a clear choice once again. The digital meter gave a much closer measurement to the expected value due to a better scale, no risk of parallax, and being significantly easier to

Related Documents

  • Improved Essays

    Nt1310 Unit 5 Lab Report

    • 483 Words
    • 2 Pages

    6/10/2015 Mrs Rummins | GRUJICIC, Marko Background: Another name for I/V characteristics is current-voltage. Current and voltage are the factors that are being investigated, there characteristics and effects in diodes of different colours. The Current or I in I/V characteristics refers to the flow of an electric charge.…

    • 483 Words
    • 2 Pages
    Improved Essays
  • Decent Essays

    Nt1310 Unit 1 Lab Report

    • 157 Words
    • 1 Pages

    Three test tubes where number 1-3, the first and second test tubes (#1,#2) where mark at 1cm and 5cm from the bottom of the test tube while test tube #3 was mark at 3cm and 7cm. Test tube #1 was filled up to the 1cm mark with distilled water and to 5cm with Hydrogen peroxide. The substance was swirl for 30 seconds and the height of the bubbles column where recorded. Test tube #2 was fill up to the 1cm mark with catalase and to the 5cm mark with hydrogen peroxide. The substance was swirl for 30 second and the height of the bubbles column where recorded.…

    • 157 Words
    • 1 Pages
    Decent Essays
  • Superior Essays

    Nt1310 Unit 4

    • 1249 Words
    • 5 Pages

    The first part of the experiment was determining the resolution of the DAC in volts. Before a voltage was applied the noise was determined by measuring the DC offset, the reading of the DMM at an input of zero volts. This offset was removed from the recorded values in order to provide a more accurate reading of the resolution. These corrected values and their corresponding applied voltages can be found in Table 1 of the appendix. The lowest value recorded from the DMM was -9.968V and the highest value recorded was +9.968V making the range of the DMM about 19.94±0.01V. Using the equation for calculating resolution, the resolution was calculated for values of N from 10 to 18 in increments of 2 (recorded in Table 2).…

    • 1249 Words
    • 5 Pages
    Superior Essays
  • Improved Essays

    Lower Sample Rate (22,050 SR, 128 kbps): 8/10 Since there was some slight static, we gave the sample a 8/10. This could have occurred because of the rustling of the recorders jacket. Since the phone was placed close to the recorder, this sound could have been easy to pick up by the recording device. I think if we were able to listen to the recording with headphones, it would have been a more accurate depiction of the quality. There was some breathing and wind sound that could be heard in the background noise, especially in the rainbow passage reading.…

    • 543 Words
    • 3 Pages
    Improved Essays
  • Decent Essays

    Nt1310 Unit 1 Lab Report

    • 372 Words
    • 2 Pages

    Name ____________________________________ Lab-Getting Trendy Pre-Lab 1. Which property uniquely identifies a chemical element? (hint: the element’s “social security number”) ______________________ 2. Describe the general characteristics of metals, nonmetals, and metalloids. ______________________________________________________________________________________________________________________________________________________ 3.…

    • 372 Words
    • 2 Pages
    Decent Essays
  • Decent Essays

    Nt1310 Unit 6 Lab Report

    • 269 Words
    • 2 Pages

    In a day to day situation, if we want to find how much time does it take a person to go from Point A to Point B, we can use the equation T= D/V. In this equation, D represents the distances in meters between Point A and Point B, and V represents the speed (meter/ second) of how fast a person walks. In mathematical terms, it uses the total distance traveled to divided by the time to get an estimation of the average speed(second). But, if we want to find out the age of the universe ? Then, we need to take it into the universe’s perspective.…

    • 269 Words
    • 2 Pages
    Decent Essays
  • Improved Essays

    Determining the impact of Auxin in pea plants, and its effect on lateral bud growth Megan Posey Bio 121-104 John Barry 10/23/16 Abstract Auxin is a hormone that helps to regulate bud growth, cell elongation, and many other aspects of plants. Apical dominance is a phenomenon that occurs due to the presence of auxin and stops lateral bud growth.…

    • 1635 Words
    • 7 Pages
    Improved Essays
  • Improved Essays

    Chesapeake Bay Lab Report

    • 1073 Words
    • 5 Pages

    During our experiment, we had a hard time measuring the conductivities of the solutions in the beaker, because the Vernier LabQuest readings didn’t’t always give us an exact number. The readings of few tests kept running, so we ended up estimate a number for the conductivity. But these errors didn’t’t really affect our experiment that much. A future experiment could test the pH level in the…

    • 1073 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    Universal Limus Strips

    • 231 Words
    • 1 Pages

    IF I tested the pH of certain substances with both litmus strips and a pH meter THEN I expected to see minimal to no deviation between the measured results of both methods. I measured the pH level of the following substances: lemon juice, fish tank water, tea, mouthwash, Sea…

    • 231 Words
    • 1 Pages
    Improved Essays
  • Improved Essays

    Rockport Walking Test

    • 582 Words
    • 3 Pages

    Identify possible sources of error in this lab. Walking is not the best method to calculate VO2 max as it is a submaximal test. There could be a miscalculation regarding your heart beat or the VO2 max equation. 3. Assess the practicality of using this lab in the field.…

    • 582 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    Wingate Test Analysis

    • 803 Words
    • 4 Pages

    1. What energy system(s) does the Wingate Test rely? Explain. The energy systems that the Wingate test relies on, is glycolysis and ATP-PCr.…

    • 803 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    The first time I took it, my results showed that I had no automatic preference between…

    • 834 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    These errors may range from human errors to equipment errors. Internal resistance within the voltmeter may cause a reduction in measured voltage values thereby giving voltage results that are too low or too high. These result influence the overall E cell value rendering results incorrect. Corrosion on the alligator clip that was used could prevent consistent contact of the electrode thereby giving fluctuating results throughout the experiment. Electrode touching the salt bridge in the beaker while a measurement was taken can also influence the measured voltage by the voltmeter.…

    • 1122 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    We still had not gotten to a voltage that we were happy with but we were running out of time so we took a video of what we had. My partner then suggested that we try to turn our anemometer vertical. This was a change that made the biggest difference to the effectiveness of our design. I personally…

    • 735 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    We decided to use the probe first, then we used the spring scale. We rarely experienced any changes in our data because the same people were doing the experiment. The only change that we experienced in our…

    • 892 Words
    • 4 Pages
    Improved Essays