Molarity Of Acid Calculations

Improved Essays
Register to read the introduction… M) * MM(CH3COOH)
(0.5967M) * (65.05 g/mol) = 35.85 g/L

4) Percent Acid ((g/L)/(given density)) * 100
((35.85 g/L)/(1005 g/L)) * 100 = 3.57%

UNKNOWN ACID 1) Moles of NaOH ((Vf - Vi)/1000) * M

Run #1: ((31.11 – 0.51)/1000) * 0.2116m = .006475

Run #2: ((31.35 – 0.38)/1000) * 0.2116m = .006553

2) Calc Moles of Acid because 1:1 ratio moles acid equals moles NaOH moles acid = Run 1: .006475 and Run #2: .006553

3) Molar Mass (grams used/moles acid)
Run #1: (1.3160g/.006475) = 203.24 g/mol
Run #2: (1.3276g/.006553) = 202.59 g/mol 4) Average Molar Mass (203.24 + 202.59)/2 = 202.92
…show more content…
When solving for the percent of acetic acid present in vinegar the end result of 3.57% was not far off from the standard 4%. The small error could be a result of error in experiment or an actual failure of the acid to meet the federal standard. An example of error in experimentation is while the solution is titrated completely, the flask being swirled is removed from underneath the buret and a drop or two of NaOH can sneak out before the valve is closed. Those few missed drops as well as excess NaOH in titration can affect the accuracy of the results. Human error is almost always a factor for example when measuring any values without digital assistance leaves room for the naked eye to make mistakes. As far as the second part of the experiment was, the 0.0025% deviation indicates that the titration was accurate. The ending molar mass (202.59 g/mol) of the mystery acid points to two possible suspects. The first being Cesium Diuranate, and the second Sodium Diuranate. Without the information it wasn’t possible to determine which one it would be. There is also a chance that the results had small deviation (accurate) but were not precise. For example if both titrations had error due to the mass of the samples being incorrect. There was also a potential error during the second titration. While adding the indicator to the acid solution the tip came in

Related Documents

  • Great Essays

    Vitamin Water Experiment

    • 1575 Words
    • 7 Pages

    The 3 methods were calibration plot method, standard addition and standard addition by graphic procedure. The 3 methods are generally good methods to determine the amount of an analyte in sample. But there were a couple huge mistakes made in this experiment. The first was, using a serological pipette instead of volumetric pipettes. Serological pipettes are not as accurate as volumetric pipettes, and will not deliver exactly the same volume as indicated.…

    • 1575 Words
    • 7 Pages
    Great Essays
  • Improved Essays

    Chemical Reaction Lab

    • 970 Words
    • 4 Pages

    Finally, the starch solution used for the both labs is not reliable, because instructions were not definite and contained the words “spray generously.” These experimental errors could be resolved by preventing contamination by using different wells each time, using a thermometer to create more precise temperatures for more accurate data, creating new solutions before doing trials, and finding exact, proportional values to create the starch solution. These two labs had an abundance of experiment error, however, The second lab was more accurate than the first, because it consisted…

    • 970 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    Offender Profiles

    • 1008 Words
    • 4 Pages

    Had this not occurred there was the possibility that internal validity of the study would be compromised. Nonetheless, there are several limitations to be considered in the application of this study. First, the experience in profiling versus no experience in profiling provides a limitation on how reliable the application of profiling is in a case. If the participant has no experience their view on how useful profiling is when put into place can be skewed, allowing their belief to improperly represent the facts. A second limitation is the lack of representation found within the sample, as the way in which it was created is extremely biased.…

    • 1008 Words
    • 4 Pages
    Improved Essays
  • Great Essays

    The molar mass of KHP was 204.22g. Molarity x Volume (L) = Moles of KHP Moles of KHP x Molar Mass of KHP = grams of KHP 0.1 x 0.05 = 0.005 moles of KHP 0.005 x 204.22 = 1.0211 g KHP Dilution of NaOH and HCl To find out how to dilute NaOH and HCl the equation M1V1 = M2V2 is used. For both the M1 and V1 were given as 0.1 and 250 mL respectively. The M2 was given as 3. The equations were set up as follows: g HCL = 0.1 x 250 = 3 x V2 → (0.1 x 250)/3 = V2 = 8.3 g HCl g NaOH = 0.1 x 250 = 3 x V2 → (0.1 x 250)/3 = V2 = 8.3 g NaOH Preparation of Ascorbic Acid Solution The vitamin C tablet was crushed and 0.5 grams of ascorbic acid was mixed with 50 mL of deionized water to form the Ascorbic Acid Solution Preparation of NaHCO3 solution The baking soda was measured to 0.5 grams and was mixed with 50 mL of deionized water to form the Sodium Bicarbonate Solution.…

    • 1340 Words
    • 6 Pages
    Great Essays
  • Improved Essays

    Observed/theoretical X 100 1.476 g/3.08 g X 100=47.9% Discussion of Results: There was too much error introduced into the experiment to be able to indicate exactly which product was obtained through the experiment. I believe the results were supposed to include the product being erythro-2,3-dibromo-3-phenypropanoic acid and the mechanism that took place in the experiment was in fact the bromonium ion mechanism. My group’s percent error was 47.9% which is extremely low. This low percent error was gained from the lack of mass of the product obtained after vacuum filtration. There are several sources of error that could have given this result including: the product not being dry enough after vacuum filtration, the solution not mixed enough in the experiment, much loss of the product in transferring, and excess acetic acid contaminating the product which would change the melting point of the product.…

    • 717 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    This error is fairly significant and is the result of a discrepancy in the experimental molality or freezing point depression —since both “Kf” and “i” are constant. The error in molality is due to the inaccuracy in measuring 5.0 grams of benzophenone at the beginning of the experiment; 0.507 grams were instead measured. This resulted in a smaller molality which produced greater Kf values since the values were determined by dividing the freezing point depression by the molality of solution. Additionally, there could have been an error in extrapolating the freezing point from the graph thus resulting in an inaccurate freezing point depression. A freezing point depression greater than the actual freezing point depression would result in a greater Kf value than the accepted value when divided by the molality of the…

    • 929 Words
    • 4 Pages
    Improved Essays
  • Superior Essays

    Copper Sulfate Lab

    • 2021 Words
    • 9 Pages

    Mass of copper sulfate and tare weight of the beaker – Mass of 100 mL beaker = Mass of copper sulfate 53.84g – 50.89g = 2.95g The mass of the copper sulfate is 2.95g. 3. Mass of starch and tare weight of filter paper – Mass of the filter paper = Mass of starch 3.46g – 0.50g = 2.96g The mass of the starch is 2.96g. 4. Mass of water / Mass of Mixture #6 x 100% = Percent of water 32.68g / 38.59g x 100% = 84.68% The percent of water in the mixture is 84.68%.…

    • 2021 Words
    • 9 Pages
    Superior Essays
  • Improved Essays

    It put us really behind and in the process of changing the crucible some mass of MgO was lost. However, we did get the reaction we were expecting but not the right result. In conclusion, our empirical formula for MgO was not calculated because we did not finish the experiment. We did not reach to the point where we had to extract all the Mg3N2 by adding distilled water and reheating the Mg so the rest of O2 can react with it and give us pure…

    • 1338 Words
    • 6 Pages
    Improved Essays
  • Improved Essays

    Sharmistha Santra A Thermometric Titration Table: (Representing the results obtained from the experiment) Known Acid HCl 1 mol dm-3 (± 0.100) Unknown Acid HCl 0.76 mol dm-3 (± 0.100) Highest Temperature (Time) 28.5 (190s) 28.6 (235s) Lowest Temperature (Time) 22.9 (55s) 22.9 (55s) Sample Calculation for the Unknown Concentration C1V1 = C2V2 1 (190 - 505) = C2 (235 - 505) 1 28.0 = C2 37.0 C2 = 2837 C2 = 0.760 mol dm-3 (±0.0500) Sample Calculation for the amount of mole in Unknown Acid Mole = Concentration Volume Mole = 0.760 (±0.0500) (235 - 505) (±0.0100) Mole = 0.760 (±0.0500) 37.0 (±0.0100) Mole = 28.0 mol (±6.73) Sample Calculation for Uncertainty of Mole ±0.05000.76 100 = ±6.700% ±0.010037 100 = ±0.0300%…

    • 1009 Words
    • 5 Pages
    Improved Essays
  • Great Essays

    Pill Cam Disadvantages

    • 1226 Words
    • 5 Pages

    The third disadvantage is fecal matters that might block the shots captured by the pill cam. Due to this, the lens of the camera might be blocked by dirt and the outcome would be that the dirty lens would spoil the shots much of the way through [3]. The fourth limitation is it cannot enter on narrow areas. Meaning, clogging…

    • 1226 Words
    • 5 Pages
    Great Essays