Liquid Chromatography Lab

Improved Essays
High performance liquid chromatography (HPLC) is a separation technique utilizing differences in distribution of compounds in two phases; called the stationary phase and the mobile phase. The stationary phase designates a thin layer created on the surface of fine particles and the mobile phase designates the liquid flowing over the particles. Under a certain dynamic condition, each component in a sample has a different distribution equilibrium depending upon the solubility in the phases and or molecular size. As a result, the components move at different speeds over the stationary phase and are thereby separated from each other. These components are separated from one another by the column packing that involves various chemical and/or physical interactions between their molecules and the packing particles. These separated components are …show more content…
Mobile phase is constantly fed into the column inlet at a constant rate by a pump. The sample is injected from a sample injector, located near the column inlet. The injected sample enters the column with the mobile phase and the components in the sample migrate through it, passing between the stationary and the mobile phases. Compounds move in the column only when they are in the mobile phase. Compounds that tend to be distributed in the mobile phase therefore migrate faster through the column while compounds that tend to be distributed in the stationary phase migrate slower. In this way, each component is separated on the column and sequentially elutes from the outlet. Each compound eluting from the column is detected by a detector connected to the outlet of the column.
PRINCIPLE OF RP-HPLC
In RP-HPLC compounds are separated based on their hydrophobic character.retension is the result of interaction of then nonpolar components of the solutes and the non-polar stationay phase. Figure 2 High Performance Liquid Chromatography

Related Documents

  • Great Essays

    The neutralization of the reaction was verified using pH paper to test whether the pH was neutral or slightly basic. At this point, the two possible products in the round bottom flask could have been exo- and endo-norborneol. Extraction and washing was performed and the exo- and endo-norborneol products formed were extracted into dichloromethane due to their similar solubilities, where the two products are overwhelmingly non-polar despite the one hydroxyl group. The dichloromethane (DCM) was the bottom layer formed, while the aqueous layer, the layer that was washed away, was the top and this was due to the weight of the chlorine atom that made DCM more dense. Extraction was repeated several times due to the partition coefficient, as it theorizes how smaller extractions are better than bigger extractions because they yield more concentrated extractions in the end.…

    • 1629 Words
    • 7 Pages
    Great Essays
  • Superior Essays

    Gas Chromatography Lab

    • 1038 Words
    • 5 Pages

    Figure’s 3, 5, and 6 had injection temperatures set at 230, 210, and 250 °C respectively. The best retention time separation of the three was the sample with the injection temperature set at 250°C. This was then the injection temperature that would be used for the rest of the data collected. Figure’s 6, 7, 8, 9, and 10 address the optimal elution volume of methanol part of the experiment. Figure’s 6, 7, 8, 9, and 10 had elution volumes of 2 mL, 3 mL, 4 mL, 5 mL, and 6 mL respectively.…

    • 1038 Words
    • 5 Pages
    Superior Essays
  • Improved Essays

    In this experiment, pinacol was mixed with sulfuric acid, which protonated the pinacol, allowing it to form a better leaving group. Water is the leaving group off of the pinacol and the pinacol becomes a carbocation. The carbocation that is formed is a secondary carbocation so, rearrangement occurs. A methyl shift happens to form a tertiary carbocation, which is more stable than a secondary carbocation. Then, the remaining oxygen forms a double bond causing it to have a positive charge; allowing the carbon that had a positive charge to have a full octet and to be neutral.…

    • 454 Words
    • 2 Pages
    Improved Essays
  • Improved Essays

    Identification of Unknown Compounds 64A and 64B 64A, was a white powdery solid substance. 64B, was a clear colorless liquid that had the smell of alcohol. Solubility analysis is a method of identifying compounds based on how their behavior in other compounds. Solubility is the ability of a solvent to dissolve a solute.…

    • 762 Words
    • 4 Pages
    Improved Essays
  • Superior Essays

    Identifying an Unknown Compound Using Various Chemical Analysis Techniques Joshua Nash and Aquilla Young Abstract The introduction of this lab report exposes the reader to the different scientific concepts that are to be used such as melting point calculations, retention factors, and solubility in various aqueous solutions. The experimental provides the basics of using a melting point apparatus, determining solubility, and performing thin layer chromatography. In the results section the findings of my experimental are tabulated and presented in a well-organized manner so that the reader can understand how each value was calculated.…

    • 2190 Words
    • 9 Pages
    Superior Essays
  • Improved Essays

    Purpose The purpose of the experiment Thin Layer Chromatography was to analyze compounds, Aspirin, a mixture of Tylenol with ethanol, acetaminophen, a mixture of Excedrin with ethanol, Aspirin, and acetaminophen, Anthracene, Benzyl, and Triphenylmethanol by separating them with the help of silica plates. Procedure Three silica plates were taken and on the plastic side, they were all marked 1 cm above its end using a pencil. With the help of capillary tube, the first and the second plates were spotted with Aspirin on the left and Acetaminophen on the right. The middle of the first plate was then spotted with the mixture of Tylenol and ethanol but the middle of the second plate was spotted with the mixture of Excedrin and ethanol.…

    • 623 Words
    • 3 Pages
    Improved Essays
  • Improved Essays

    To study further, the beginning question could be “To what extent does the type of solvent used affect the distance a spot of a substance travels in…

    • 692 Words
    • 3 Pages
    Improved Essays
  • Decent Essays

    For the Thin-Layer Chromatography (TLC) we tested the unknown A and the unknown B. Unknown A, has a similar Ratio Factor (RF) of the known sample of Caffeine which have a 0.31 mm and for the unknown B, it has a similar RF of Acetaminophen which have a 0.63- 0.69 mm, so me and lab partner concluded that the unknown samples that have similar RF of the known samples are the same materials. For equation 2, which have a 33% volume. Then for equation 3, which is the Areas of; 1- propanol is equivalent to 14.5 cm, 1- butanol is equivalent to 15 cm, 1- pentanol is equivalent to 17.5 cm. For equation 1, the percent of each samples collected are;…

    • 213 Words
    • 1 Pages
    Decent Essays
  • Improved Essays

    Gas Chromatography

    • 758 Words
    • 4 Pages

    In this lab, a hexane and octane mixture was purified, through distillation, to pure octane. The distillation could be completed because part of the solution, hexane, had a lower boiling point than the other, octane, allowing it to evaporate out. Throughout the experiment, four samples were taken and tested by gas chromatography. Gas Chromatography, or GC, was used to analysis the components of each fraction taken during the experiment. Upon looking at the data, the presence of hexane in the fractions decreased, whereas, the presence of octane increased.…

    • 758 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    After starting with 30 mL of an unknown mixture of two solvents, fractional distillation and gas chromatography were used to identify the unknowns as acetone and toluene in a 1 to 2.04 ratio of acetone to toluene. Fractional distillation was first used to separate the unknown mixture into its components based on boiling point. Distillation refers to the method of separating components of a mixture through heating and cooling. Simple distillation, which is especially useful in the separation of less-volatile substances from volatile substances, such as sugar from water, can be used to separate a liquid-liquid mixture if the boiling points of the component liquids differ by more than 40-50°C. A plot of temperature versus volume for a simple…

    • 958 Words
    • 4 Pages
    Improved Essays
  • Improved Essays

    DISTILLATION The purpose of experiment 1, fractional distillation and gas chromatography, was to separate an unknown organic mixture into two liquids. The primary process of separation was fractional distillation, which utilizes the physical properties of the two unknown volatile liquids. Once the unknown mixture was successfully fractioned, gas chromatography was used to help determine the identity of the two unknown liquids. Fractional distillation and simple distillation both take advantage of two major physical properties to separate liquids.…

    • 1163 Words
    • 5 Pages
    Improved Essays
  • Improved Essays

    Cyclohexanol Lab Report

    • 786 Words
    • 4 Pages

    Data/Observations: In the chromatogram of a mixture of cyclohexanol and heptanal, there are 8 peaks. Retention times are 1.783, 2.111, 2.181, 2.832, 3.798, 4.012, 4.268, and 4.351 (min) in an increasing order. Areas are 5193372, 27743, 1333, 1283, 4005, 1734332, 3526677, and 2079050. Each area corresponds to each retention times.…

    • 786 Words
    • 4 Pages
    Improved Essays
  • Decent Essays

    Cheyenne Wilson 5.05 LAB REPORT CANDY CHROMATOGRAPHY BACKGROUND INFORMATION: Paper chromatography is a widely used method of separation. The lab will show the basic techniques of paper chromatography. In this lab, the separation of the dyes used in two different kinds of candy is performed.…

    • 618 Words
    • 3 Pages
    Decent Essays
  • Improved Essays

    Abstract This experiment involved an electrophilic aromatic substitution of bromobenzene. Two products were formed: 4-nitrobromobenzene (4-NBB) and 2-nitrobromobenzene (2-NBB). Utilizing column chromatography and recrystallization, separation and purification of the two products was obtained. The mass of 4-NBB, the para product, was 1.57 grams, while the mass of 2-NBB, the ortho product, was 0.80 grams.…

    • 1570 Words
    • 7 Pages
    Improved Essays
  • Superior Essays

    Cyclograosus Essay

    • 1575 Words
    • 7 Pages

    If too much of the sample liquid entered the capillary tube, some was removed by lightly tapping the tube on a paper towel. In each of the capillary tubes the sample liquid was moved to the middle of the tube by lightly tapping it; once the liquid was in the middle both ends of the tube were sealed by plugging both ends with some Vaseline. The capillary tubes were then arranged in sequence along the tube holder with a space between the 3 groups. The alcohol bath was then prepared by placing dry ice into it in order to lower the temperature to around -15°C. Gloves or paper towels were used to handle the dry ice.…

    • 1575 Words
    • 7 Pages
    Superior Essays