Cerebrovascular Reactivity (CVR)

Superior Essays
Cerebrovascular reactivity (CVR) refers to the change in cerebral blood flow (CBF) in response to a vasoactive stimulus (Kety and Schmidt, 1948). Impaired CVR has been linked with many cerebral and cerebrovascular pathologies (Glodzik et al., 2013; Greenberg, 2006a; Han et al., 2008; Mandell et al., 2008c; Mikulis et al., 2005; Yezhuvath et al., 2012; Zhao et al., 2007), to study the effects of drugs on cerebral vasculature (Pattinson et al., 2007; St Lawrence et al., 2002) and also presurgical planning (Zaca et al., 2011a). Impaired CVR was also found as a risk factor stroke for patients with carotid artery occlusion and stenosis (Silvestrini et al., 2000), has been studied in connection with dementia (Gupta et al., 2012; Silvestrini et al., …show more content…
The subject was fitted with a nose clip and a mouthpiece to allow mouth breathing. The subject inspired room air and the hypercapnic gas in an interleaved fashion (60 sec CO2 followed by 60 sec room air, repeated three times with additional 60 sec room air inhalation at the end). The subject with sealed nose breathed through a mouth piece that connected to a 5% CO2 gas bag or room air. The composition of the hypercapnic gas was 5% CO2, 74% N2 and 21% O2. The type of air inhaled was switched via a valve in a 1min interleaved manner while BOLD images and physiologic parameters (end-tidal CO2, breathing rate, heart rate, and arterial oxygenation) were continuously collected for 7min. A research assistant was always present inside the scanner room during the experiment to monitor the subject and switch the valve that controls delivery of hypercapnic gas and room air. End-tidal CO2 (Et-CO2), which measures the concentration of CO2 in the lungs and represents a surrogate for concentration of CO2 in the arterial blood, was recorded for the entire duration of the scan using a capnograph device (Capnogard, Model 1265, Novametrix Medical Systems, CT). Imaging parameters used in this study were FOV = 220 ? 220 mm2, matrix size = 64 ? 64, 43 axial slices, thickness = 3.5 mm, no gap, TR/TE/flip angle = 2000 ms/25ms/80?, single-shot EPI. …show more content…
The error bar represents standard error. Note that the c was significantly greater than zero.
4.4 Discussion
In this study the nonlinearity in BOLD response to EtCO2 change was investigated for moderate hypercapnia. Contrary to sigmoidal response hypothesized previously for ramped stimulus, we observed opposite pattern i.e. inverse sigmoid pattern in BOLD response. A new biophysical model was proposed to account for this non-linearity. We found that the non-linear model showed improved r2 which is an indicator of good ness of fit for a model. This would suggest that the new proposed model better describes the BOLD response. We then investigated the age long variation in the fitted parameters in BOLD response We found that there is non-linearity the BOLD response present irrespective of age and this non-linearity is significantly greater than zero. Suggesting the nonlinearity may be governed by other factors independent of aging. We also found significant age related changes to EtCO2 and these changes was mostly driven by the changes in male

Related Documents

  • Improved Essays

    Analysis Of Variance

    • 1822 Words
    • 8 Pages

    Interestingly, the mean amplitude of Graph 2 shows slightly a significant change between modality, the paired samples t-test provided no significant effect except FC2. The source memory over FC2 was the most positive waveform of FN400 than others (Graph 2). Thus, it has been found that acoustic brands had a larger negative amplitude than visual brands at FC2, even though the amplitudes not seen in this Graph 2 due to more positivity, paired samples t-test found a significant difference t(30) = 2.31, p = .028, but not at F1 t(30) =1.48, p = .153 (Figure 2, Graph 2). As a conclusion, the modality effect could not determine according to peak amplitude except FC2 which visual brands had larger positive peak than…

    • 1822 Words
    • 8 Pages
    Improved Essays
  • Improved Essays

    The intercept is significant at a 1%. This can be understood as whenever p and q are equal to zero, the intercept can be read as the sample mean; however in this case where p and q are bigger than zero it will still be close to the sample mean but usually not identical as it is not the maximum likelihood estimate whenever p and q are bigger than zero. The AR(1) coefficient is significant at 10% with estimate of 0.31523, interpreted as a correlation of the current period GDP with the previous period as shown in equation 1.1. Moreover, shocks to highly correlated data will propagate and take more time to neutralize. Looking at figure 1.a we see that after the Q4 2008 shock, the GDP level takes several quarters to recover the trend it previously had.…

    • 4164 Words
    • 17 Pages
    Improved Essays
  • Great Essays

    At this point the starting condition for the experiment was established. The starting pressure P, height of oil h in the measuring chamber and the air temperature T in the measuring chamber were recorded. The measurement was repeated for every 30mm drop in oil level, until a height of 30mm was reached. This was done by carefully…

    • 1196 Words
    • 5 Pages
    Great Essays
  • Improved Essays

    The Gibb’s free energy change of adsorption was found to be in range of -2.6 to -0.05KJ/mole. These results indicate that the adsorption of stearic acid complex is feasible and spontaneous. The enthalpy(ΔH) and entropy(ΔS) were found negative and positive values respectively. The negative value of enthalpy confirmed that the adsorption of stearic acid complex is an exothermic process. This can be due to energy released after the adsorption process being higher than that need to the solvent molecules.…

    • 793 Words
    • 4 Pages
    Improved Essays
  • Superior Essays

    The preparation of graphene is as follows: The expandable graphite was mixed with powder melamine in volume ratios of 1:1 and 1:3 to produce several mixtures as shown in table 2-1. The mixtures were dispensed into the de-ionised water to make solutions with a concentration of 1g/100ml. The solutions were then heated up to and kept at 80oC for 1 hour with constant stirring. This is to allow the melamine to fully penetrate and expand the graphite spaces. Later, the solutions were filtrated and dried for five hours at 80oC.…

    • 1355 Words
    • 6 Pages
    Superior Essays
  • Superior Essays

    Color Analysis Lab

    • 1098 Words
    • 5 Pages

    The previously determined Ka gave a percent error of -21.91%, this error could be due to several reasons including, but limited too: calibrating the ph electrode correctly or possibly spilling the solutions when transferring from bottle to bottle. A negative percent error means that the actual yield was higher than the theoretical yield, which was given at a literature value of 7.9*10^-8. Comments and…

    • 1098 Words
    • 5 Pages
    Superior Essays
  • Improved Essays

    The Lab Quest had to be adjusted so that the interval was 15 s/sample and so that the duration was 480 seconds. The calorimeter was then constructed by staking two Styrofoam cups together and lacing them in a 400 mL beaker. 100 mL of 6M HCl was added to the Styrofoam cups and the initial temperature was recorded by the lab quest. One gram of MgO was weighed out using scale and watch glass and all weights were recorded in table 2. After the initial temperature was recorded the MgO was quickly added and the cup was swirled while the temperature changes were recorded.…

    • 1835 Words
    • 8 Pages
    Improved Essays
  • Improved Essays

    (1979). Pipetted out 0.1ml of gastric tissue homogenate, 0.2 ml of 8.1% sodium dodecyl sulfate (SDS), 1.5 ml of 20% acetic acid solution and 1.5 ml of 0.8% aqueous solution of TBA into suitably labeled test tubes. The reaction mixture was then made up to 4.0 ml with distilled water and heated at 95°C for 60 min in water bath. After cooling the test tubes under tap water, 1.0 ml of distilled water and 5.0 ml of the mixture of n-butanol and pyridine (15: 1, v/v) was added and shaken vigorously. Centrifuged the test tubes at 4000 rpm for 10 minutes and the absorbance of the upper layer were measured at 532 nm.…

    • 801 Words
    • 4 Pages
    Improved Essays
  • Decent Essays

    Then, a solution of 0.5 M Zn(NO3)2.6H2O was added dropwise under constant stirring. For collection of core ZnO, half portion of the material was filtered and washed several times with deionized water and ethanol. The washed samples were dried at 650 C in the oven for 1 hour. The shell CdS nanoparticles were prepared by simultaneous addition of Cadmium Acetate solutions and Sodium Sulfide (Na2S) solutions. The synthesis was carried out at room temperature.…

    • 748 Words
    • 3 Pages
    Decent Essays
  • Superior Essays

    NTG Case Study Essay

    • 1409 Words
    • 6 Pages

    (Firat et al., 2013). Also GCC loss was found to be more localized in NTG, compared to diffuse loss in PAOG. (Kim et al., 2013). Differential Diagnosis: 1) POAG with apparently normal IOP due to diurnal fluctuation. 2) Previous episodes of high IOP due to trauma, uveitis or steroids therapy.…

    • 1409 Words
    • 6 Pages
    Superior Essays