Who's approval is required for a planned exceptional exposure dive. And who also has to be on-station?
CNO

DMO
What are the pneumofathometer correction factor limits?
0-100 +1
101-200 +2
201-300 +4
301-above +7
What is the depth of the Last Water Stop?
20fsw
What is the limit or max time at 20fsw or shallower?
There is no limit at 20fsw or less
What and where is it located in the dive manual, the Optional Shallow Water No-D Table
Table that breaks down the No-D schedule into one-foot increments at 30-50fsw

Appendix 2A
For Air/O2 stops the diver follows the T/S up to 30fsw or 20fsw if there is no 30fsw stop and then shifts to ____ and begins time once confirmed.
100% Oxygen
All decompression stops deeper than 30fsw use?
Air
What does ORCA stand for and what is it?
Oxygen Regulator Console Assembly

delivers oxygen to divers in water the Fly-Away Mixed Gas System (FMGS) is already cable of this without using an ORCA.
After shifting to 100% O2 how long do you vent each diver and can you do them at the same time? What must be verified after shifting?
20sec.

Yes

100% O2 is being transfered via O2 analyzer
How long can the divers breathe 100% O2 for at one time? How long is the break in between? Do you need to vent during the air break
30min

5 min air break (dead time)

No vent required
What if the final O2 stop time is 35min do you need to do the air break and take the divers off 100% O2?
No, the divers can come to the surface after the stop time is complete only if the FINAL stop is 35min or less
While divers are ascending at what depth does the Surface Interval start and stop. On a Sur-D dive?
40fsw to 50ft in the chamber
What is the approximate or optimal undress time?
03::30
3minutes 30seconds
Is an inside tender required if 2 divers dove and are doing a Sur-D dive? (unharmed)
No, the Dive Sup may elect to only have the 2 divers go in the chamber and watch each other.
What is the compression rate while traveling to 50fsw in the chamber?
100fsw/min
What is the ascent rate from the bottom to 40fsw? and then from 40fsw to the surface?
30fsw/min to 40fsw

40fsw/min to surface
What is the max Surface Interval from 40fsw to 50fsw in the chamber without incurring a penalty?
5 min
How long is a half O2 period and how long is a full O2 period?
15min

30min
After a dive if no repet group designator is shown how long must you wait before diving again?
18 hours
Can the dive sup decide to shift from in-water decompression to Sur-D anytime?
Yes, at 30fsw or 20fsw
While at 30 or 20fsw the divers where already on O2 could that time be subtracted from the amount of O2 time required in the chamber?
Yes, multiply the remaining O2 times by 1.1 then divide that by 30 and round up to the next highest half period.
What is the minimum requirement in the chamber?
50fsw for 15min.
Air to O2 trading ratio is?
Air stop requirement / O2 stop requirement = X
X / by remaining air time = Y
(Y x 1.1) / SurD O2 period = Z
(This card is hard to answer shortly)
Basically divide Air time and O2 time to get air/O2 ratio.
What is the best coarse of action for dives that require less than :15min of decompression?
In-water decompression
If the total air/O2 decompression time in the water is greater than ____ , SurD O2 is required unless _____ authorizes planned exceptional exposure dives are conducted.
90 min

CNO
When you add your Residual Nitrogen Time (RNT) to the bottom time of your repet dive you obtain what?
Equivalent Single Dive Time
(ESDT)