Each plumbing fixture, except for those having integral traps, shall be ________________.
seperately trapped by an approved liquid seal trap
One trap may serve a set of not more than ______________ single compartment sinks.
three
A food waste disposal unit installed in restaurant, commercial, or industrial sinks ____________.
must be individually trapped
The maximum vertical distance for a tailpiece allowed between a fixture and the trap weir is _________________ inches.
24
Each plumbing fixture trap shall be protected against siphonage and back pressure by a ________________.
vent pipe
A trap arm smaller than 3 inches may change direction without a cleanout if the change in direction does not exceed ________________ degrees.
90
The vent pipe opening from a soil or waste pipe, except for water closets and similar fixtures __________________.
shall not be below the weir of the trap
The maximum horizontal distance a trap arm shall be from the trap to the vent opening for a 2 inch trap is ___________ feet.
5
Each trap, except for traps within interceptors or similar devices, __________________ .
shall be self cleaning
No more than _______________ approved slip joint fitting(s) may be used on the outlet side of a trap.
one
The size of the trap connected to a fixture shall be sufficient to drain the fixture rapidly, but
cannot be smaller than the fixture drain nor can it be more than one size larger than the fixture drain
No trap shall be used that __________________.
depends on movable parts, has concealed interior partitions, or is classified S or Bell trap
Each fixture trap shall have a water seal _________________.
between 2 and 4 inches
Floor drains shall connect into a trap so constructed that it can be _______________.
readily cleaned
Floor drains or similar traps directly connected to the drainage system and subject to infrequent use shall be __________________________.
protected with an accessible trap seal primer, except when not deemed necessary by the Authority Having Jurisdiction
Each building trap when installed shall be provided with __________________.
a cleanout and a relieving vent or fresh air intake on the inlet side of the trap
Interceptors shall be provided when, in the judgement of the Authority Having Jurisdiction, they are necessary for the proper handling of liquid wastes containing ________________.
sand and/or solids
Interceptors for sand and similar heavy solids shall have a water seal of not less than _______________ inches.
10
Interceptors shall _____________________.
be properly vented and covers that are readily accessible for service and maintenance
Every public or private wash rack and floor or slab used for cleaning machinery or machine parts shall ______________________.
be protected from storm and surface water and drain or discharge into an approved interceptor
Laundry equipment that does not have integral strainers shall discharge into an interceptor having a wire basket or similar device that will prevent the passing of solids ____________________ inch or larger in maximum dimension.
1/2
The Authority Having Jurisdiction had mandated grease pretreatment for the following fixtures: four non-emergency floor drains, two commercial food prep sinks, one mop sink with a 3 inch trap, and two dishwashers discharging 20 gpm each. The minimum size gravity grease interceptor in gallons should be ___________________.
1,000
Each plumbing fixture connected to a type A and B hydromechanical grease interceptor shall be provided with a ____________________.
flow control device
Each fixture discharging into a gravity grease interceptor shall be _______________________.
individually trapped and vented
The total capacity in gallons of fixtures discharging into any hydromechanical grease interceptor shall not exceed _______________ times the certified gpm flow rate.
2 -1/2
Sand interceptors shall be required ___________________________.
with heavy discharge or when the AHJ deems it so
The sand interceptor shall have a minimum dimension of _________________ square feet for the net free opening of the inlet section and a minimum depth under the invert of the outlet pipe of _______________ feet.
2, 2
Sand and similar interceptors shall have a water seal of not less than _____ inches.
6
All repair and gas stations with grease racks or grease pits and all factories that have oily and/or flammable wastes shall be provided with an oil or flammable liquid interceptor that shall ___________________________.
be connected to all necessary floor drains and independently vented with a vent not less than 2 inches
Interceptors not rated by the manufacturer shall have a depth of not less than _______________ feet below invert of the discharge drain and an outlet opening with not less than a _______________ inch water seal.
2, 18
If the AHJ determines that a grease interceptor is not being properly cleaned, the AHJ has the authority to mandate a _________________________________.
maintenance program
A ________________________ shall be installed downstream of hydromechanical grease interceptor in accordance with the requrements of this code.
vent
Gravity grease interceptors shall not be installed in any part of the building where ________________________.
food is handled
The volume of the gravity interceptor shall be determined by using _______________.
Table 1014.3.6
Gravity grease interceptors shall be placed as close as practical to the _______________.
fixture they serve
It is rcommended that a ______________ be located at the outlet end of all gravity grease interceptors.
sample box
Abandoned grease interceptors shall be _____________ and _______________ as required for abandoned sewers and sewage disposal facilities.
pumped, filled
Water closets and urinals shall _____________ into or through a grease interceptor.
not drain
Listed ____________ may be used to connect listed metal tubing traps.
plastic adapters
Grease interceptors shall at all times be _____________ for inspection, cleaning, and removal of grease.
easily accessible