Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
34 Cards in this Set
- Front
- Back
When presented with a basement fire what should be palced at the entry to the structure during operations?
|
Jacl Ladder
|
|
Approximately what percentage of roof systems built in the U.S. are of truss construction?
|
60%
|
|
Approximately what percentage of one and two family homes built in the U.S. are of light weight construction?
|
80%
|
|
With the Canberra MCB2 ABG Meter what should you suspect with a background reading of 10X?
|
Radiological incident
|
|
With the Canberra MCB2 ABG Meter when should you suspect contamination of personnel?
|
When you get a reading of 3 or 4 times background on personnel
|
|
When arriving at a building with a water based fire protection system where should the first engine be positioned and what should be their initial actions?
|
They should position within 50' of the FDC and immediately connect a minimum of two 3" double jacketed high pressure supply lines.
|
|
What is the recommended initial sprinkler system pump pressure?
|
150 psi + 5 psi/per floor elevation pressure
|
|
When responding to a sprinklered structure what does no visible smoke or fire potentially indicate?
|
The fire is very small and one or two sprinklers have extinguished fire or sprinklers have not yet operated.
|
|
When responding to a sprinklered structure what does an outside water flow alarm motor gong operating potentially indicate?
|
That water is flowing into the system
|
|
When responding to a sprinklered structure what does visible steam potentially indicate?
|
Sprinklers have operated and probably have the fire under control or contained.
|
|
When responding to a sprinklered structure what does visible heavy fire and/or smoke potentially indicate?
|
Sprinkler system is not operational and/or the supply valve is closed.
|
|
Should fire personnel attempt to reset a dry sprinkler system once it has operated?
|
No
|
|
What paperwork is required by the IC after a sprinkler system activation?
|
Sprinkler Report
|
|
What items are required to be maintained on-site in a structure with a sprinkler system per NFPA 13.
|
At least 6 spare sprinkler heads and a special wrench
|
|
When is it generally quicker to use a buildings standpipe system rather than lay out hoseline?
|
When the fire is located more than four floors above the lowest access leveland/or where the building size and complexity will require attack lines in excess of 400 ft.
|
|
What is the minimum amount of hose that should be carried in the standpipe kit?
|
150 ft of 2" line
|
|
What should be your initial standpipe pumping pressure?
|
150 psi, add 50 psi /10 floors
|
|
In a high-rise operation what hose and tip does the CFD use?
|
2" attack line with a 1" smooth bore tip.
|
|
The pressure on the piezometer hooked up to the outlet on the floor below the fire with water flowing should read what?
|
90 psi for a 150 ft layout. For a 100 ft layout the piezometer should read 78 psi.
|
|
What is the restricted distance from the hoseline if 250 psi pump pressures must be used?
|
50 ft to each side.
|
|
What is the minimum height a building must be to be considered a high rise by the CFD?
|
75 ft.
|
|
What should be included in the size up report for a high rise structure?
|
CERTAIN
(C) Confirm working fire/smoke showing (E) Establish/Identify location of command post (R) Report type of occupancy (T) Trapped occupants (A) Approximate number of floors/height (I) Identify fire floor (N) Name of building |
|
In a high rise structure what must be done prior to initiating horizontal ventilation?
|
Obtain the approval of the incident commander
|
|
What is deemed the fire area in a high rise structure?
|
The fire floor and two floors above
|
|
Where should occupants of the fire area be relocated to?
|
To an area of refuge at least three floors below the fire floor
|
|
What is the recommendation of how many floors in a high rise structure can be evacuated at the same time?
|
Three floors
|
|
To evacuate non-ambulatory residents what control scheme should be used for the elevators in high rise structures?
|
Phase II operations
|
|
What is the maximum number of department members allowed in a passenger elevator at one time?
|
Six
|
|
What floor should the fire be above to allow use of the elevators in a high rise fire?
|
5th floor
|
|
If using an elevator to get to the fire scene in a high rise structure on which floor should you stop?
|
At least two floors below the lowest floor reporting smoke.
|
|
Can elevators be used in below grade fires?
|
No
|
|
How much of a floors air volume can the plenum space above the ceiling contain?
|
As much as 25%
|
|
Who conducts the primary search of the top five floors and evacuation stairwell in a high rise structure?
|
4th arriving ladder company
|
|
What equipment must all memebrs take into a high rise building?
|
1. PPE/SCBA
2. Walkie Talkie 3. Flashlight 4. Extra SCBA bottle |