Decribe the automatic drain separators on a divers air compressor.
Automatic drain separators
are commonly small and
installed between the stages of air compressors.
Why are moisture separators needed in diving systems?
Moisture separators are installed in diving systems to collect and remove as much moisture as possible before the air is delivered to the storage flasks.
What are the two types of separators used in diving systems?
The two types of separators
used in diving systems are
automatic drain and the manual drain.
What is the most common type of H.P. Moisture Separator?
The most common type of H.P.
Moisture Separator found in diving systems is the MIL-F-22606
Where can you find the MIL-F-22606 moisture Separator?
The MIL-F-22606 Moisture Separator can be found in the Navy stock system.
What date is used to establish the recertification test cycle when installing a refurbished moisture separator flask?
When installing a refurbished flask, the date the unit is actually placed into service
is the date used for establishing the recertification test cycle.
True or False?
All diving systems with compressors must have a moisture separator located upstream of the compressor?
False. All diving systems with compressors must have a system moisture separator located DOWNSTREAM of the compressor.
Where must the moisture separator be installed for maximum efficiency?
For maximum efficiency, the separator must be installed in a straight length of pipe at least 10 pipe diameters downstream of the nearest valve or fitting.
Where are moisture separators located compared to the compressor after-coolers and the system filters?
The separator should be located downstream of the compressor after-coolers to trap the condensation resulting from the air cooling
process but prior to the first
system filter.
Why are moisture separators always installed prior to the backpressure regulator?
They should always be installed prior to the
backpressure regulator to prevent damage to the backpressure regulator from compressor pressure fluctuations.
True or False?
Moisture separators are also effective in removing a high percentage of the oil vapor from divers air.
True. These separators are also effective in removing a high percentage of the oil vapor normally discharged
by oil lubricated compressors.
How is moisture removed from manually operated moisture separators?
All manually operated separators must be provided
with drain valves to remove collected moisture. DUHHH!
What is the MIL-F-22606 moisture separators constructed of?
MIL-F-22606 moisture separators are constructed of HY80 steel.
Except for the MIL-F-22606 what are the other divers air compressor moisture separators typically made of?
Other moisture separators vary in their construction materials, but are typically fabricated from stainless steel or bronze.
When selecting a moisture separator for a divers air compressor what 3 variables determin the separator size?
The separator capacity (size) is selected based on the compressor output pressure, temperature, and flow.
What is the Floodable
Volume of a Mil-F-22606 moisture separator?
0.5 cubic feet
During compressor
operation, how often is the moisture separator blown down?
Separators shall be blown down at least once per hour of compressor operation.
If there are two compressors discharging into one moisture separator, how often is the moisture separator blown down?
If there are two compressors discharging into one moisture separator then bleed-down shall occur at least once every half-hour while both
compressors are operating.
On compressors with interstage separatore that are manually opperated how often must they be blown down?
Manually drained compressor
separators must be drained at
least every 15 minutes during
compressor operation.
Compressors with automatic
separator blow-down shall be
checked...
A. periodically
B. every :15
C. every :30
to ensure proper operation.
Compressors equipped with automatic separator blow-down shall be checked...
A. periodically
to ensure proper operation.
In accordance with PMS how often are the external inspection for the MIL-F-22606? How often are all other moisture separators inspected?
MIL-F-22606 separators
require annual inspections, all others require 18 month
inspections.
How often are MIL-F-22606 moisture separators tested
by Ultrasonic (UT) or Acoustic
Emission (AE)?
MIL-F-22606 H.P. moisture
separators shall be tested
by Ultrasonic (UT) or Acoustic
Emission (AE) testing at
least every 7 years.
How often are "non" MIL-F-22606 moisture separators tested and by what means?
Stainless steel and bronze
moisture separators receive
an internal and external
visual inspection at intervals
not to exceed 18 months.
What are the cleaning requirements for all moisture separators?
Moisture separators shall be
cleaned to the same requirements as the system where they are installed.
When are moisture separators required to be cleaned?
Cleaning is required when the separator is initially
installed and anytime
cleanliness is lost.
How are moisture separators required to be tagged?
All moisture separators require a tag to be affixed upon completion of the recertification testing.