NFPA 1981
|
Open circuit, positive pressure demand system equipped w/ a RIC UAC and HUD
|
|
NFPA 1982
|
PASS
|
|
Cylinder
|
Seamless aluminum core
Carbon fiber wrapped Covered w/ epoxy resin Weighs 14.1lbs 66 cu ft air capacity 45 min bottle 4500 psi |
|
Cylinder Valve Assembly
|
Constructed of forged aluminum
Locking tab-locks into back frame Dual sided pressure guage w/ elastomeric bumper Tri-directional burst disk (700 deg or 7500 psi) Safety Hand wheel |
|
Two-stage pressure reducer
|
1st stage-reduces pressure to 85-110psi
2nd stage-reduces pressure to 145-165psi -activates when 25% air or upon failure of 1st stage Controlled by a low cylinder transfer valve |
|
SCOTT EZ FLOW MMR
|
Reduces pressure from Two-stage pressure reducer to 15.2psi
Purge Valve: used to defog mask or bypass MMR if malfunction occurs Air saver donning switch Vibralert: signals low air or failure of 1st stage Resistant to CBRN Air directed upward into mask-9 ports on spray bar Low pressure regulator hose |
|
HUD
|
Heads up Display
Activates when system is pressurized Initializes for 20 sec and all 5 lights illuminate 4 lights for air status, 1 light for battery 2 solid green=full 1 solid green=3/4 Flashing yellow=1/2 Flashing red=1/4 Low batt=light will flash 1x/sec |
|
AV 3000 Full Facepiece
|
Polycarbonate plastic-hard coated to resist abrasion
Kevlar straps and harness Rubber nose cup and face seal |
|
SCOT EPIC Voice amplifier
|
Power button
Green LED light: solid=power, flashing=low batt (2 hrs left) Automatic power off after 20 min of inactivity 3 AAA batt-last approx 20 hrs |
|
PAK ALERT SE+Distress Alarm
|
Control Console: Remote pressure guage, manual alarm button, reset button
Sensor Module - motion sensor and audible alarm Pre Alarm: activates if motionless for 20 sec and resets w/ movement Full Alarm: activates 12 sec after Pre alarm resets w/ reset button 2x Manual Alarm: activated by pressing manual alarm button |
|
EBSS
|
Dual manifold w/ male and female quick disconnects
3ft high pressure hose Couplings compatible w/ MMR low pressure hose |
|
RIC UAC
|
RIC Universal Air Connection
Used to hotfill bottle of downed FF Emergency use only Fill no faster than 1500psi/min Not compatible w/ EBSS |
|
Back frame/harness
|
Constructed of stamped aluminum
Kevlar straps Nomex pads Alligator and/or parachute clips Weighs 14lbs |
|
Drop bag
|
75ft
7mm nylon static kernmantle Used for SAR, lower/raise equip, self rescue |
|
Policy 6.E.110
|
SCBA Use
The use of SCBA is mandatory for all personnel working under the following conditions; Where the atmosphere is known to be hazardous. Where the atmosphere is suspected to be hazardous. Where the atmosphere may rapidly become hazardous Toxic atmospheres Oxygen deficient Elevated temp/Explosive Smoke conditions |
|
Policy 6.E.400
|
SCBA Safety Check
Daily 4000psi min |
|
SCBA Maintenance
|
Inspected daily and after each use
Hydrostatic date: every 5 yrs Life span: 15 yrs Clean w/ soft bristle brush, mild soap, water Damage observed-remove from service, tag w/ description, email description to Testa/Bogin, send to sta 4 |