NFPA 1981
Open circuit, positive pressure demand system equipped w/ a RIC UAC and HUD
NFPA 1982
PASS
Cylinder
Seamless aluminum core
Carbon fiber wrapped
Covered w/ epoxy resin
Weighs 14.1lbs
66 cu ft air capacity
45 min bottle
4500 psi
Cylinder Valve Assembly
Constructed of forged aluminum
Locking tab-locks into back frame
Dual sided pressure guage w/ elastomeric bumper
Tri-directional burst disk (700 deg or 7500 psi)
Safety Hand wheel
Two-stage pressure reducer
1st stage-reduces pressure to 85-110psi
2nd stage-reduces pressure to 145-165psi
-activates when 25% air or upon failure of 1st stage
Controlled by a low cylinder transfer valve
SCOTT EZ FLOW MMR
Reduces pressure from Two-stage pressure reducer to 15.2psi
Purge Valve: used to defog mask or bypass MMR if malfunction occurs
Air saver donning switch
Vibralert: signals low air or failure of 1st stage
Resistant to CBRN
Air directed upward into mask-9 ports on spray bar
Low pressure regulator hose
HUD
Heads up Display
Activates when system is pressurized
Initializes for 20 sec and all 5 lights illuminate
4 lights for air status, 1 light for battery

2 solid green=full
1 solid green=3/4
Flashing yellow=1/2
Flashing red=1/4
Low batt=light will flash 1x/sec
AV 3000 Full Facepiece
Polycarbonate plastic-hard coated to resist abrasion
Kevlar straps and harness
Rubber nose cup and face seal
SCOT EPIC Voice amplifier
Power button
Green LED light: solid=power, flashing=low batt (2 hrs left)
Automatic power off after 20 min of inactivity
3 AAA batt-last approx 20 hrs
PAK ALERT SE+Distress Alarm
Control Console: Remote pressure guage, manual alarm button, reset button

Sensor Module - motion sensor and audible alarm

Pre Alarm: activates if motionless for 20 sec and resets w/ movement
Full Alarm: activates 12 sec after Pre alarm resets w/ reset button 2x
Manual Alarm: activated by pressing manual alarm button
EBSS
Dual manifold w/ male and female quick disconnects
3ft high pressure hose
Couplings compatible w/ MMR low pressure hose
RIC UAC
RIC Universal Air Connection

Used to hotfill bottle of downed FF
Emergency use only
Fill no faster than 1500psi/min
Not compatible w/ EBSS
Back frame/harness
Constructed of stamped aluminum
Kevlar straps
Nomex pads
Alligator and/or parachute clips
Weighs 14lbs
Drop bag
75ft
7mm nylon static kernmantle
Used for SAR, lower/raise equip, self rescue
Policy 6.E.110
SCBA Use

The use of SCBA is mandatory for all personnel working under the following conditions;

Where the atmosphere is known to be hazardous.

Where the atmosphere is suspected to be hazardous.

Where the atmosphere may rapidly become hazardous

Toxic atmospheres
Oxygen deficient
Elevated temp/Explosive
Smoke conditions
Policy 6.E.400
SCBA Safety Check

Daily
4000psi min
SCBA Maintenance
Inspected daily and after each use
Hydrostatic date: every 5 yrs
Life span: 15 yrs
Clean w/ soft bristle brush, mild soap, water
Damage observed-remove from service, tag w/ description, email description to Testa/Bogin, send to sta 4