define rise
|
deck or overhead to center of damage
|
|
define uncorrected run
|
bulkhead to anchor point
|
|
define corrected run
|
compensates for the thickness of wedge, strongbacks, ect
|
|
define shole
|
a flat plate used under strongbacks to distribute pressure over the damage
|
|
what are the two purposes of a strong back?
|
distribute pressure and serve as a anchor point
|
|
the maximum length of a wood shore is ___ times the minimum butt thickness
|
30
|
|
what are the 2 lengths of the steel shoring
|
3-5 & 6-11
|
|
what is the maximum weight the short steel shoring will hold when fully extended? when closed?
|
12,000 lbs , 20,00 lbs
|
|
what is the maximum weight the long steel shoring will hold when fully extended? when closed?
|
6,000 lbs , 20,000 lbs
|
|
what are two ways of measuring for K-type shoring?
|
measuring batten/shoring batten , carpenter square
|
|
what is another name for I-type shoring
|
direct compression
|
|
what is another name for H-type shoring
|
cross-exial
|
|
what is another name for K-type shoring
|
triangulation
|
|
equipment shall be stored "first in, ___ out."
|
last
|
|
PECU stands for
|
Portable Exothermic Cutting Unit
|
|
PECU cuts at approximately ____ degrees Fahrenheit
|
10,000
|
|
The PECU regulator is preset at ____ psi
|
60
|
|
PECU cutting rods come in what two sizes
|
1/4 & 3/8
|
|
How is the PEARS powered
|
12-volt batter Pack
|
|
fire compartment doors shall remain ___ during initial response to maintain breathable atmosphere for unprotected initial responders
|
open
|
|
what are the 5 steps for attacking a fire
|
size up, attack, isolate, protect exposed compartments, set fire and smoke boundaries
|
|
how many people must man a 1 1/2 inch fire hose during sustained firefighting
|
3 personal
|
|
how many people must man a 2 1/2 inch fire hose during sustained firefighting
|
4-5 personal
|
|
what are the 3 ways to control a wild hose
|
shut off water flow, z kink, advance along the hose
|
|
when using an in-line AFFF eductor, you should use a ___ GPS nozzle with the bail in ____ position
|
95 , Full Open
|
|
any ___ barrier can be a fire boundary
|
physical
|
|
the minimum degree of tightness for a secondary fire boundary is _____
|
Fume Tight
|
|
secondary boundaries are generally set at ____ subdivision or ____ boundary
|
watertight , airtight
|
|
boundaries ___ the fire shall be set as quickly as possible
|
above
|
|
define smoke control zone
|
the area between the inner and outer smoke boundaries
|
|
smoke boundaries can be set by closing doors and hatches, or by using ___ and ____
|
smoke curtains , smoke blankets
|
|
what are the 4 types of ventilation
|
general , supply , exhaust , natural
|
|
before using air moving devices, you must first get permission from
|
Cheng
|
|
box fan is rated at ___ CFM
|
3200
|
|
box fan is powered by __ volts AC
|
115
|
|
the ram fan is rated at __ CFM
|
2000
|
|
the ram fan is powered by
|
fire main
|
|
exhaust fans/blowers shall be located on the ___ decks
|
weather
|
|
who determined the need for active desmoking
|
repair party leader
|
|
what are the 7 considerations in selecting a fan
|
potential explosive of fire hazard, space available, operating temp., effing ect
|