- Front
- Back
Which .exe's need access through a personal firewall for RB Mobile to work ?
|
rbtdebug.exe, rbtmon.exe, rbtsport.exe, rbtlogger.exe, and shmobile.exe.
|
|
Which port is used to allow SSH access to the Steelhead Mobile Controller from a remote site.
|
Port 22
|
|
Which ports are used to allow Web access (including HTTP and HTTPS).
|
Ports 80 and 443
|
|
What is the default port used between the Steelhead Mobile Client and the remote Steelhead appliance for all optimized TCP sessions?
|
Port 7800.
|
|
Which port needs to be open on the network firewalls if you configure the Steelhead Mobile Client to establish optimized connections with server-side out-of-path Steelhead appliances?
|
Port 7810.
|
|
Which port is used by the client to send statistics to the Mobile Controller?
|
Port 7870
|
|
Where do you set the datastore size for Mobile clients?
|
Endpoint settings page on the Mobile Controller.
|
|
Which WCCP service groups does Riverbed recommend?
|
Riverbed recommends that you use WCCP service groups 61 and 62.
|
|
What are the options for creating an RSP backup ?
|
FTP, SCP or local backup library.
|
|
How much RAM needs to be added for RSP support?
|
2GB of additional RAM is required for RSP support.
|
|
Which Steelhead models have two in-path interfaces as standard?
|
1050, 2050, 5050, 6050, 7050 all have duel in-path ports on board a sstandard.
|
|
Which are the 3U models?
|
5050, 6050, & 7050 Steelheads.
|
|
What are the 1U steelhead models?
|
1050 & 2050
|
|
What are the desktop model steelheads?
|
250 & 550 are the desktop models.
|
|
What type of cable does the SH fail to?
|
Fails to CROSS OVER
|
|
What is the CLI command to clear all stats?
|
UALHORB1 # stats clear-all
|
|
What is the command to launch the configuration wizard ?
|
UALHORB1 (config) # configuration jump-start
(Admin only command) |
|
What is the cli command to factory reset ?
|
#reset factory
|
|
Can a Virtual SH be managed by a CMC ?
|
Yes.
|
|
What type of cable does the SH fail to?
|
Fails to CROSS OVER
|
|
What is the CLI command to clear all stats?
|
UALHORB1 # stats clear-all
|
|
What is the command to launch the configuration wizard ?
|
UALHORB1 (config) # configuration jump-start
(Admin only command) |
|
What is the cli command to factory reset ?
|
#reset factory
|
|
Can a Virtual SH be managed by a CMC ?
|
Yes.
|
|
What form factors is the CMC appliance available in?
|
1U only.
|
|
What are the datastore encryption options?
|
AES 129, AES 192 & AES 256 bit encryption. (no encryption also available.)
|
|
What is the probe TCP option number?
|
0x4c / 76
|
|
How many clients does the mobile controller support?
|
100 for the virtual unit, 4000 for the appliance.
|
|
What is the probe response TCP option number?
|
0x4e / 78
|
|
What is the minimum size of the mobile datastore?
|
256MB
|
|
What is the maximum size of the mobile datastore?
|
20GB
|
|
Do the peering rules include a discard option?
|
No
|
|
What is the total HDD size of the Interceptor ?
|
Zero. It has no disk.
|
|
What is the form factor of the Interceptor ?
|
3U
|
|
What is the Optimized WAN Capacity range for the Steelhead 250 series ?
|
1Mbps to 2Mbps.
|
|
What is the Optimized WAN Capacity range for the Steelhead 550 series ?
|
2Mbps to 4Mbps.
|
|
What is the Optimized WAN Capacity range for the Steelhead 1050 series ?
|
4Mbps to 20Mbps.
|
|
What is the Optimized WAN Capacity range for the Steelhead 2050 series ?
|
45Mbps.
|
|
What is the Optimized WAN Capacity range for the Steelhead 5050 series ?
|
90Mbps to 155Mbps.
|
|
What is the Optimized WAN Capacity range for the Steelhead 6050 series ?
|
310Mbps
|
|
What is the Optimized WAN Capacity range for the Steelhead 6050 series ?
|
1Gbps
|
|
What is the
Optimized TCP Connections range for the 250 series SH appliance ? |
30 - 200
|
|
What is the
Optimized TCP Connections range for the 550 series SH appliance ? |
300-600
|
|
What is the
Optimized TCP Connections range for the 1050 series SH appliance ? |
600-2300
|
|
What is the
Optimized TCP Connections range for the 2050 series SH appliance ? |
2500 - 6000
|
|
What is the
Optimized TCP Connections range for the 5050 series SH appliance ? |
7500 - 18,000
|
|
What is the
Optimized TCP Connections range for the 6050 series SH appliance ? |
50,000
|
|
What is the
Optimized TCP Connections range for the 7050 series SH appliance ? |
75,000 - 100,000
|
|
What are the two different states of admission control?
|
Flowing & paused.
|
|
What are the two reason that admission control could be triggered?
|
Number of connections exceeded vs licence and memory limits.
|