  • Front
  • Back

when to wear your personal radiation monitor

anytime when working with radiation

dose response relationship is a relationship between different _ doses and t he _ of the observed dose

radiation, magnitude

basis for radiation protection standards is _ _ dose response relationship

linear, non threshold type

define linear

exposure increases, risk increases

radiation exposure limits set by

IRCP

MPD

max permissible dose

MPD

annual recommended dose or regulatory dose limits

MPD whole body

rad worker - 20mSv


public - 1mSv

MPD lens of eye

rad worker - 150mSv


public - 15mSv

MPD of skin, hands, other organs

rad worker - 500mSv


public - 50mSv

accidental exposure - owner responsibilites

ensure equipment installed and used at level of good safety standards

three principle ways to describe patient exposure

ESE, GSD, MMD

for mobiles, operator must stand out of _ _ at least _ meters away from tube

primary beam, 3meters

_ gives more exposure than radiography

fluoroscopy

highest occupational exposure comes from

mobile, fluoro, angio

at 100kv, lead drapes must have _

0.25mm lead eq

at 100kv, bucky slot over must have _

0.5mm lead eq

test protective equipment _

yearly

equal or less than _ unaccceptable for protective equipment

670mm^2

equal or less than _ diatmeter circle unacceptable if in thyroid or gonad area

5mm

ESE uses _ to measure

TLDs

ESE is higher than _

absorbed dose

calculating ESE

mR/mAs

GSD

gonadal dose (genetic dose)

MMD

mean marrow dose

MMD

average bone marrow exposure over entire bone marrow of person

if 25% of active bone marrow recieves 30mrad, MMD is

30mrad/4 = 7.5 mrad

MMD

is a somatic index


MMD measures _ not _

dose, effect

MMD estimates lower in _ since bone marrow spread through entire body and exposures are lower

children

equipment requirements for CT

irradiation control, visual indications, emergency termination, focal spot to skin distance, x-ray beam quality, preview image, light field, motion of patient support

CR imaging plates

reuseable, exposed, read and erased repeatedly

_ visual inspection recommended and _ cleaning following manufacturer recommendation

weekly, month