93 Cards in this Set

  • Front
  • Back

What is the min height that a vent can terminate above a door or window?

1 meter

What is the max # of circuit vented branch traps that can be installed between a circuit vent and a relief vent?

8 traps

Scd 10 is the lightest scd pipe used when victolic grooving


True or false?

true

The max # of FU that can drain into a vent stack @ the lowest storey is?

8 FU

A roof that is 900 square meters and smaller needs how many roof drains?

2

What is the purpose of a parabolic weir on a storm drainage system?

Slow down volume of water going through the roof drain

Minimum size of water service pipe for a single family dwelling?

3/4"

Expansion joints for RWL's must be installed ___________ from the hopper?

5 ft

What is the minimum and maximum water pressure @ the point of entry into a building?

Min = 29 psi or 200 kpa


Max =80 psi or 550

Max temp of water discharge from a sterilizer without a requirement for cooling is?

170 F

The max allowable temp of water to be delivered from a mixing valve is ________.

- 120 F or 49 C



A temp sensing valve will deliver water @ a max temp of ________?

120f or 49C

What is the minimum amount of elbows required to make an expansion joint on a RWL?

2


Flow control drains may be installed provided:


1.) The max drain down time doesnt exceed __________?


2.) They are located not more then ______ from the edge of the roof and not more then ______ from adjacent drains?

1.) 24 hours


2.) 15m and 30m

Distance between cleanouts on a 3 or 4" line from two way rodding is?

30m

What is the max vertical drop for a WC trap arm?

1M

When testing a water system with air what pressure must be maintained and for how long?

100 psi for 2 hours

When a water test is required for underground DWV how much ft of head must it be subjected to?

10 ft of head

According to environment canada, how is a RWL sized?

Max amount of rainfall recorded over a 25 year period during a 15min period

When is a vent stack required?

When a soil or waste stack discharged through 5 stories or more

Can you drain into a Yoke vent?

Yes, must be vertical section of the Yoke vent. Max 2 fixtures connected symmetrically and each fixture doesnt exceed 1.5 FU

Where must a vent stack connect to the soil/waste stack it's serving? What is the minimum size of vent stack?

Must connect to a vertical section of the soil/waste stack at or immediately below the lowest pipe connect to the stack

A yoke vent need not be installed provided the the soil/waste stack is interconnected with the vent stack in each storey of the section in which fixtures are located by means of a vent pipe equal in size to the branch or fixture drain or 2", whichever is smaller

2.5.4.3(4)

When is a Yoke vent required?

When a soil/waste stack goes through 12 stories or more.It's installed every 5 floors starting from the top down.

How do you size a yoke vent?

One pipe size smaller then the smallest pipe it is connect to

When a soil/waste stack offsets, it requires a offset relief vent when?

-Nominally horizontal offset more then 1.5 M


-Passes through more then 2 storeys


-Hydraulic load more then100 FU

A vent stack is required when fixtures discharge from a min of how many stories?

5

The size of a vent for a sewage pump is?

One size small then the largest inlet. atleast 2" but no more then 4"


How many FU's can drain into a additional relief vent and a circuit vent?

Max 2 fixtures connected symmetrically not bigger then 1.5 FU each

When should you install a re-circ line?

Higher then 4 stories or hot line is longer then 30M

Can fixtures with fixture outlet pipes less then 2" connect to the drain portion of a circuit vent?

Yes, but they must be separately vented or separately circuit vented

What size of flashing is used for a vent on a roof?

20"x20"

Where must a vent terminate through a roof?

-Through a residential roof 150mm
- 3.5M away from a air intake and 1M above
-3.5M from another building

What is the smallest vent pipe that can penetrate through a roof?

3"

1 PSI = how many kpa?

6.9kpa

What application is a turbine meter best suited for?

Industrial water pumps and equipment



How many check valves does a RP have?

2

The atmospheric vacuum breaker shall not be installed where it is under continuous flow for more then ?

12 hours

An atmospheric vacuum breaker shall be used on ?


(severity)

non lethal and non toxic

A pressure vacuum breaker device shall never be installed lower then_____ above the flood level rim?



12"


normally used in a supply line to a fixture


Check this answer

How many shower heads can a single drain handle on a gang shower?


What is the floor graded at?

Max 6 shower head graded at 1/4" per ft

Legionella thrives in what temperature?

120F or 49C and lower

Why would you install multiple pressure reducing valves in series?

To allow for pressure reduction greater then that provided by a single valve




not 100% on this answer

Why would you install multiple pressure reducing valves parallel from each other?

To allow the use of 2 smaller, less expensive valves rather then one large expensive valve

Max temp of sewage or clear water waste drained into a drainage system?

75 C or 170F

How many check valves does a pressure vacuum breaker have?

1

What is the distance required above a double check valve assembly when using a sight tubes for testing?

3 ft

A wet vent extends through more then 1 storey, the total discharge from any 1 storey above the 1st doesnt exceed?

4

What is the min height that a vent could terminate above a balcony?(public use)

2m(6ft6")

What temp should you set your HWT to?

140F 60C

What type of backwater valve must be installed on a building drain?


Norm open or closed?

Norm open so there can be free flow of air through the system.

Barrier Free Notes



1.5m radius


470 + or - 10 wall to center of WC


430 + or - 30 floor to seat



What feature on a optimal level allows it to be used for measuring distances?

Stadia lines

What is the spacing distance for shock absorbers on a battery of fixtures?

20 ft

What is the min distance a water meter must be from any wall or entrance?

12"

What temp is water cooled for a drinking fountain

10C

Weeping tile must rest on what size of rock and by what dimension?

1" rock


12"x12"

A floor drain can be connected to a storm drain




true or false?

true

A floor drain 3" or bigger must be a min of 18" away from the BD or branch.




True or false

true

One trap may serve a group or floor drains, shower drains, a group of washing machines or a group of lab sinks if the fixtures are in the same room and arent located where they can receive food or other organic matter

What is the purpose of the shield on the bubbler on a drinking fountain?

Prevents contamination of the nozzle

Whats the max amount of FU's that can drain into a relief vent?

6FU

Thermostat anticipator


-The anticipator is wired in series with the thermostat contacts. If the heat anticipator burns out due to a incorrect voltage being applied the circuit is broken

Can victaulic be used on copper systems?

Yes

Max distance a cleanout can be from the base of a soil/waste stack?

10 ft

A double sanitary tee fitting shall not be used to connect the trap arms of?

Back outlet WC's

Max directional change for a kitchen sink before a vent has to be installed?

90 degrees

What is the min. cleanout size for a 8" building sewer?

Manhole

How many toilets can be wet vented?

2

Minimum size of trap for a bidet?

1 1/4"

Mapp gas uses what 2 types of gas?

Acetylene and propane

Where would you install a cast iron base meter?

Where freezing might occur.

Most common type of booster pump?

Centrifugal pump

All meters need to be grounded.


true or false?

true

State 2 advantages of a electric HWT

Quiet


More choice of location(no flue)

What type of backflow preventer is installed on a flush valve?

Vacuum breaker

Which family does the fill valve belong to?

Needle

What is the min. trap seal depth?

1 1/2"

Floor drains cant be installed in high voltage rooms or anywhere toxic or flammable material is stored.




true or false?

true

What is the min. size of a floor drain?

2"

Min. trap arm length must be how long?

2x pipe diameter

A sump pump need 3 fittings in what order?

Union


check valve


ball or gate valve




remember "U check valve"


union closest to pump

When fixtures are below grade what must you install to the drainage?

Norm closed backwater valve

The pressure vacuum device will or will not be used where it is subject to back pressure?

will not

Gang showerheads must be no closer then?

30"

When a offset in a soil/waste stack is great then 1.5 meters, how is it sized?

as a branch or building drain

What side of a pressure reducing valve would you install a pressure RELIEF valve?




downstream or upstream?

downstream

Is a check valve necessary on a booster pump system?

yes

A downspout from a ease trough connected to sub soil drainage need a cleanout where?

12" above grade

What are the 2 methods of expansion on a RWL?

1.) Expansion joint no more then 5ft from the roof drain(installed on vertical)




2.) 2 90 degree elbows, first one 5ft MAX from roof, 2nd MIN 5 ft on horizontal

Does a RWL need a trap if it's draining into a storm system?

no

What is the minimum clearance a cleanout needs for service?

12"

You can run drains and waterlines inside exterior walls.




true or false?

false, only vent lines