• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/30

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

30 Cards in this Set

  • Front
  • Back
WHAT DO THE NAVY USES TO MEASURE RADIANT AND CONVECTION HEAT TRANSFER TO OR FROM THE BODY?
WBGT METER OR AUTOMATED HEAT STRESS SYSTEM (AHSS).
THE WBGT INDEX IS CALCULATED USING ____,____, AND ___.
DRYBULB, WET-BULB, AND GLOBE TEMPERATURE
WHAT IS PHEL?
PHYSIOLOGICAL HEAT EXPOSURE LIMITS. HOW LONG AN INDIVIDUAL MAY BE EXPOSED SAFELY TO HEAT STRESS CONDITION. IT IS DETERMINED BY THE WBGT INDEX AND PHYSICAL EXERTION LEVEL.
FOR SHIPS WITHOUT AN AUTOMATED HEAT STRESS SYSTEM (AHSS) INSTALLED, HOW MANY PORTABLE, CALIBRATED AND OPERABLE WBGT METERS SHOULD BE ONBOARD?
AT LEAST TWO
WHO IS RESPONSIBLE FOR REVIEW, AND INITIAL DAILY HEAT STRESS SURVEYS THAT RESULT IN REDUCED STAY TIMES?
CO
WHO REVIEW ALL ENGINEERING AND NON-ENGINEERING HEAT STRESS SURVEYS TO DETERMINE OBVIOUS INACCURACIES, REDUCED PHEL STAY TIME?
MDR
WHO ENSURE DRY BULB THERMOMETERS ARE INSTALLED AND TEMP ARE MONITOR AND RECORDED?
EACH DEPARTMENT; REACTOR, SUPPLY, ENGINEERING...
PLACEMENT OF THE ______ THERMOTERS MAY BE IN OR OUT OF VENTILATION AIR STREAM, BUT MUST BE HUNG AT LEAST _____FT FROM ANY SUPPLY VENTILATION TERMINAL/OPENING.
DRY BULB; 2 FEETS
WHAT IS USED TO OBTAIN ACCURATE AND RELIABLE DATA ON HEAT STRESS CONDITION ONBOARD SHIPS?
HEAT STRESS SURVEY RECORDED BY DRY, WET AND GLOBE TEMPERATURE
TRUE OR FALSE

DRY BULB THERMOMETERS DO NOT REQUIRE CALIBRATION.
TRUE
AUTOMATED HEAT STRESS SYSTEM LOCATED NEAR VENTILATION, THE SENSOR SHOULD BE LOCATED IN RELATION TO THE VENTILATION DUCT IN SUCH THAT AIRFLOW TO THE SENSOR DOES NOT EXCEED _____ FPM.
600
WHAT MUST BE AVALIABLE ON BOARD SHIPS, IF AHSS WORKSTATION IS UNAVAILABLE DUE TO POWER FAILURE SECURING OF THE WORKSPACE, ETC.
DRY BULB THERMOMETER
IF DB TEMPERATURE EXCEED 100,90,85 THE SPACE SUPERVISOR SHALL____, THE DB READING AND ____. THE WATCH SUPERVISOR SHALL DIRECT HEAT STRESS SURVEY TO BE CONDUCTED AND ENFORCE THE RESULTING STAY TIME.
CIRCLE IN RED; NOTIFIED WATCH SUPERVISOR
WHAT IS USED TO DETERMINE ENVIRONMENTAL HEAT STRESS CONDITION?
WBGT METER
THE HEAT STRESS SURVEYOR SHALL CONDUCT THE FIRST WBGT MEASUREMENT IN THE WORKSPACE _____ MINUTES TO ENABLE IT TO EQUILIBRATE TO THE SUROUNDING AREA AND ____ FOR THE NEXT LOCATION.
5 MINUTES; 3 MINUTES
THE SURVEYOR SHALL RECORD THE HANGING DRY BULB TEM ON HEAT STRESS SURVEY SHEET. IF THE DIFFERENCES BETWEEN THE HANGING DB THERMOMETER AND THE DB TEM MEASURED WITH THE WBGT METER IS ________, THE DB IS NOT REPRESENTATIVE OF THE TEM AT THE WORKSPACE.
5 DEGREE OR GREATER
____ SHALL PROVIDE A FISCAL YEAR-END SUMMARY OF SHIPBOARD HEAT STRESS CASES FROM THE WESS DATABASE BY TYPES OF OPS, AND SHIP CLASS TO CNO.
NAVENVIROHLTCEN
HOW MANY PHEL CURVES ARE THERE?
SIX
PHEL CURVE I
NORMAL OPS
PHEL II
DIFFICULT OR MORE ACTIVE THAN NORMAL OPS
PHEL CURVE VI
HEAVY WORK
____ IS THE FLEET'S NUMBER ONE OCCUPATIONAL HEALTH HAZARD.
NOISE- INDUCED HEARING LOSS
WHO CONDUCTS NOISE MEASUREMENT SURVEY?
INDUSTRIAL HYGIENIST, OCCUPATIONAL AUDIOLOGIST OR BY OTHER PERSONNEL TRAINED BY AN INDUSTRAIL HYGIENIST OR OCC AUDIOLOGIST
WHO RETAIN A COPY OF THE NOISE MEASUREMENT DATA?
SAFETY OFFICER
DESIGNATED HAZARDOUS NOISE AREA AND EQUIPMENT THAT PRODUCE HAZARDOUS SOUND LEVELS SHALL BE LABEL WITH __________
NAVMED 6260/2-WARNING
NAVMED 6260/2A-LABEL
WHAT IS FORM DD2215?
REFERENCE (BASELINE) HEARING TEST
INDIVIDUALS ASSIGN TO THE HCP WILL RECEIVE A HEARING TEST AND TRAINING ______
ANNUALLY
RESULTS OF HEARING TEST SHOULD BE PERMANENTLY RECORDED INTO______
DEFENSE OCCUPATIONAL HEALTH READINESS SYSTEM-HC (DOHRS-HC) AND HEALTH RECORD
HOW OFTEN DO MDR UPDATE THE "TICKLER FILE"?
MONTHLY
ACTIVITIES THAT DO NOT USE DOHRS-HC, SHOULD CONTACT THE ______FOR GUIDANCE IN INCLUDING TEST DATA IN THE HEARING CONVERSATION DATA
NAVENVIRHLTHCEN