Standby NESW pump auto starts
|
low pump discharge pressure(looks at unit), blackout sequence (train specific), safety injection actuation (train specific)
|
|
NESW pump trips.
|
manual, overload/overcurrent, load shed. (on load shed it starts after diesels power up unless phase B)
|
|
Explain how NESW system performs containment temperature control.
|
cas panel for the regulating valve is adjusted to maintain flow.
|
|
Describe how the duplex strainer operates to protect the NESW system function of heat removal .
|
Removes debris from the NESW to prevent fouling of systems. (gate slides back and forth, NESW only has discharge valve.
|
|
list the normal power supply to the NESW pumps.
|
11b,11c,21b,21c (600 v)
|
|
list the normal power supply to the NESW system motor op valves
|
250vdc
|
|
list the normal power supply to the Nesw system air operated valves
|
250vdc
|
|
explain the effect of the interlocks on control air compressor with low NESW supply pressure.
|
cac is interlocked to prevent start of Nesw pressure @ the vac is insufficient. (15psig) if this happens you may have to blow down the strainer.
|
|
state the normal parameters for the Nesw pump discharge pressure.
|
80-90 Psig (usually closer to 80)
|
|
state the normal range of the Nesw strainer differential pressure.
|
D/P high alarm: u1 95" h2o( backwashes @ 76") u2 97" h2o( backwashes @ 86")
|
|
Describe the Nesw system response during loss of off-site power.
|
Nesw pumps are loaded when their respective diesel generators come up to speed
|
|
Describe the Nesw system response during rough lake conditions.
|
can plug up Nesw strainers. frequent backwashing may occur. (high d/p levels) strainers @ individual loss may plug up and need to be blown down.
|