Relief valve hydro is to what pressure? |
150% max op pressure |
|
What is used as fluid for Hydrostatic relief test? |
filtered Grade B water. |
|
What must be on the purchase order for relief valve? |
required set pressure. |
|
Hydro test info must include what? |
date of test, who conducted the test, required test pressure, actual test pressure, Pass fail information, Signature of who conducted the test. |
|
Cracking pressure of a relief valve is normally? |
110% of max system operating pressure. |
|
Relief must reseat when? |
once above max operating pressure. |
|
Are pipe threads generally allowed on Oxygen systems? |
NO |
|
Teflon tape is not allowed to be used on systems with operation pressures above what PSIG? |
1500 psig |
|
How often are Relief valves tested and tagged? |
36 Months |
|
For Composite flasks what is the rupture disc replacement periodicity? Who can replace them on 3A and 3AA cyclinders? |
36 months. Only DOT certified personell. |