What are Recompression chambers used for?
Treatment of decompression sickness and AGE
Surface decompression
Pressure tests
What is Navy Recompressions Chamber Support level I?
USN certified chamber close enough to dive site to support a SUR-D with a surface interval of 5 minutes
What is Navy Recompressions Chamber Support level II?
USN certified chamber accessible within one hour
What is Navy Recompressions Chamber Support level III?
USN certified chamber accessible within six hours
During extreme circumstances when a chamber cannot be reached within six hours who can authorize the use of the nearest approved recompression chamber?
The CO
When can a non-Navy chamber accessible within one hour be used?
With approval in writing by the CNO
When can a non-Navy chamber accessible within six hours be used?
With approval in writing by the CO
When can a Navy Recompressions Chamber level I support be modified?
Based on space constraints at the site, the CO may authorize extension of the surface interval to a maximum of 7 minutes in accordance with Paragraphs 9-12.6 and 14-4.14.
What is an EEHS?
Emergency Evacuation Hyperbaric Stretcher
What is the EEHS used for?
The EEHS is a portable single lock allowing a patient to be administered oxygen at 60 feet while in transport to a recompression chamber.
What are the differences between the TRCS Mod 0, 1, and 2?
TRCS Mod 0 consists of two pressure chambers (the TRC and the TL). The two chambers are capable of being connected by means of a freely rotating NATO female flange coupling.
TRCS Mod 1 consists of just the TRC.
TRCS Mod 2 is the TRCS Mod 0 which has had the 5000 psi upgrade ECP
installed allowing it to be used with an Air Supply Rack Assembly (ASRA).
What is the minimum air requirment for category D chamber primary air supply system?
Sufficient air to press the IL once and the OL twice to 165'.
(For TRCS, sufficient air to power CO2 scrubbers must be included)
What is the minimum air requirment for category D chamber secondary air supply system?
Sufficient air to press the IL & OL once to 165' and enough air for 1 tender and 2 patients (when not on O2 ) to breathe air BIBS during 1 TT6A with
max extensions.
Do not allow oxygen supply tanks to be depleted below what psig?
Do not allow oxygen supply tanks to be depleted below 100 psig.
T/F The actuating lever of the chamber gag valves shall be lock-wired in the closed position at all times, during both normal operations and when the chamber is secured.
False. The gag valves must be closed only in the event of relief valve failure during chamber operation. Valves are to be lock-wired in the open position with light wire that can be easily broken when required.
What is he basic rules for ventilation when air is being breathed?
When air is breathed, 2 acfm for each diver at rest and 4 acfm for each diver not at rest (i.e., a tender actively taking care of a patient).
What is he basic rules for ventilation when O2 is being breathed?
When O2 is breathed from the BIBS, 12.5 acfm for a diver at rest and 25 acfm for a diver who is not at rest.
When can you use air ventalation rates while breathing O2?
If a BIBS dump system or a closed circuit BIBS is used for O2 breathing, the ventilation rate for air breathing may be used.
When can ventalation rates be ajusted by the chamber Sup?
If portable or installed O2 and CO2 monitoring systems are
available, ventilation may be adjusted to maintain the O2 level below 25% and the CO2 level below 1.5% surface
equivalent (sev).
When should a USN chamber be pressure tested?
Every USN chamber shall be pressure tested when initially installed, at 2-year intervals, and after a major overhaul or repair.
What is the depth and length of stay for aU.S. Navy diver candidate pressure test?
Stay at 60 fsw for at least 10 minutes.