- Front
- Back
What are the 3 types of mixed gas diving equipment?
|
-Surface supplied gear (MK 21 Mod 1, EXO BR MS, KM-37)
-Semiclosed circuit and closed circuit UBAs -Saturation deep dive systems |
|
What are you considerations when determining what method of mixed gas diving to use?
|
-Depth and planned duration of dive
-Equipment availability -Quantities of gas mixtures available -Qualifications and number of personnel -Type of work and degree of mobility -Environmental considerations such as temp, vis, bottom type, current, and pollution levels -Communication requirements -Need for special operations procedures |
|
What are normal and max working limits for surface supplied mixed gas diving?
|
-Normal = 300'
-Max = 380' (w/ CNO approval) |
|
On a mixed gas dive side, what minimum stations shall be manned by formally trained (NDSTC) mixed gas divers?
|
-Diving Officer
-Master Diver -Diving Supervisor |
|
A diver must have how many hours of sleep prior to making a mixed gas dive?
|
-8 hours of sleep in the last 24 hours
|
|
On a mixed gas dive side, what stations shall be manned by formally trained (NDSTC) surface supplied divers?
|
-Diver
-Standby Diver -Rack Operator -Console Operator -Timekeeper/ Recorder |
|
On a mixed gas dive side, what stations can be manned by non-divers?
|
-Tender
-Standby Tender -Winch Operator |
|
When is a DMO required on dive station?
|
-For all exceptional exposure dives and any dives exceeding the equipment normal working limits
|
|
What is the minimum equipment requirement of a mixed gas diver?
|
-MK 21 Mod 1, KM-37, or EXO BR MS FFM with tethered umbilical
-Thermal protection garment -Weight belt -Dive knife -Swim fins or shoes/booties -EGS bottle w/ submersible tank pressure gauge -Integrated diver's vest (IDV) |
|
What are some operational considerations in a mixed gas dive?
|
-Adequate mixed gas supply
-MDV required on station -DMO required on station for all exceptional exposure dives and dives exceeding equipment normal working limits -Recompression chamber required on station -Planned exceptional exposure dives or dives exceeding normal working limits require CNO approval -Breathing gas heater -Hot water suit |