1

Risk assessment & park van

2

Knock on door & intro

3

Meter location + visual check for any problems inc tampering etc.

4

Take meter reading and details such as serial number and compare with HHT

5

Identify live metalwork via VT7

6

Martindale socket plug test.


3 or more problems call SMT.


Anything less leave warning notice.

7

Ask customer to switch off any sensitive equipment.

8

Turn off consumer unit

9

Cut sealing wires

10

Check air tight Rubber gloves and visor then pull fuse out and check fuse

11

Check polarity on cut out then remove neutral case and check polarity

12

Put shroud.


Tighten any loose screws.


13

Take meter cover and any other covers such as blocks or isolators then fuse back in.

14

Check polarity on meter and any blocks etc with VT7

15

Shroud back in and dead test with glow lamp. If no neutral step test is ok

16

Rubber gloves + visor off and mark cables

17

Check cables from consumer unit are secure and change meter

18

Live and neutral id stickers and make sure installation is sound

19

Rubber gloves on.


Fuse back in.


Check polarity with VT7


20

Take fuse out and put covers back on.


Seal and crimp


Tidy up

21

Warn customer before turning on consumer unit

22

VT7 check at metal work then non intrusive volt stick test.

23

Socket test.


Last visual safety checks