SRM Power Range
|
10-9 % power to 10-3 % power
|
|
IRM Power Range
|
10-4 % power to 40 % power
|
|
LPRM Power Range
|
10-3 % power to 125 % power
|
|
APRM Power Range
|
0 % power to 125 % power
|
|
Rodblock Setpoint & When Bypassed
SRM Upscale |
Setpoint - < 1x10-5 CPS
Bypassed • Any time associated SRM channel is bypassed • Any time all four associated IRM channels are on Range 8 or above • Reactor Mode Switch in "RUN" |
|
Rodblock Setpoint & When Bypassed
SRM Inoperative (INOP) |
• Channel module unplugged
• Channel Mode Switch (AER) not in "OPERATE" • Low detector high voltage (<90%) Bypassed • Any time associated SRM channel is bypassed • Any time all four associated IRM channels are on Range 8 or above • Reactor Mode Switch in "RUN" |
|
Rodblock Setpoint & When Bypassed
SRM Downscale |
< 3 CPS
Bypassed • Any time associated SRM channel is bypassed • Any time all four associated IRM channels are on Range 3 or above • Reactor Mode Switch in "RUN" |
|
Rodblock Setpoint & When Bypassed
SRM Not Fully Inserted And Indicating £ 100 CPS |
Associated SRM channel count rate
< 100 CPS AND all four associated IRM channels on Range 2 or below Bypassed • Any time associated SRM channel is bypassed • Any time all four associated IRM channels are on Range 8 or above • Reactor Mode Switch in "RUN" • Any time associated SRM channel count rate >100 CPS • Any time all four associated IRM channels are on Range 3 or above |
|
SCRAM Setpoint & When Bypassed
SRM Upscale (High-High) |
> 2x10-5 CPS
Bypassed • When associated shorting links are installed • Any time associated SRM channel is bypassed |
|
SCRAM Setpoint & When Bypassed
SRM Inoperative (INOP) |
Loss of power to associated SRM channel only
Bypassed When associated shorting links are installed |
|
Rodblock Setpoint & When Bypassed
IRM Upscale |
> 85/125
Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" |
|
Rodblock Setpoint & When Bypassed
IRM INOP |
• Channel module unplugged or other hardware failure
• Channel Mode Switch (AER) not in "OPERATE" • Low detector high voltage (<90V) Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" |
|
Rodblock Setpoint & When Bypassed
IRM Downscale |
< 5/125
Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" • Any time associated IRM channel is on Range 1 |
|
Rodblock Setpoint & When Bypassed
IRM Not Fully Inserted |
Associated IRM detector not fully inserted
Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" |
|
SCRAM Setpoint & When Bypassed
IRM Upscale (High-High) |
> 120/125
Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" |
|
SCRAM Setpoint & When Bypassed
IRM Inoperative (INOP) |
• Channel module unplugged or other hardware failure
• Channel Mode Switch (AER) not in "OPERATE" • Low detector high voltage (<90V) Bypassed • Any time associated IRM channel is bypassed • Reactor Mode Switch in "RUN" |
|
PRNMS ROD WITHDRAWAL BLOCK
STP Upscale (Mode Switch NOT in RUN) |
> = 12%
(Reactor Mode Switch not in "RUN") |
|
PRNMS ROD WITHDRAWAL BLOCK
Neutron Flux Downscale |
< = 3.2%
(Reactor Mode Switch in "RUN") |
|
PRNMS ROD WITHDRAWAL BLOCK
LPRM Low Count |
< 20 per channel
< 3 per axial level |
|
PRNMS ROD WITHDRAWAL BLOCK
Simulated Thermal Power · Two Recirc Loop Operation |
> = 0.65W + 54.3%
(Reactor Mode Switch in "RUN") |
|
PRNMS ROD WITHDRAWAL BLOCK
Simulated Thermal Power · Single Recirc Loop Operation |
> = 0.65(W - 7.6) + 54.1%
(Reactor Mode Switch in "RUN") |
|
PRNMS ROD WITHDRAWAL BLOCK
Simulated Thermal Power · Clamped |
108%
(Reactor Mode Switch in "RUN") |
|
PRNMS ROD WITHDRAWAL BLOCK
Inoperative |
Critical self-test fault
Chassis mode switch in "INOP" Watchdog timer times out Loss of both power supplies to APRM channel |
|
PRNMS ROD WITHDRAWAL BLOCK
Recirculation Flow Upscale |
> = 113.4% (see COLR)
|
|
PRNMS SCRAM
Neutron Flux Upscale (Mode Switch NOT in RUN) |
> = 15%
(Reactor Mode Switch not in "RUN") |
|
PRNMS SCRAM
Neutron Flux Upscale |
> = 118.3%
(Reactor Mode Switch in "RUN") |
|
PRNMS SCRAM
Simulated Thermal Power · Two Recirc Loop Operation |
> = 0.65W + 61.7%
(Reactor Mode Switch in "RUN") |
|
PRNMS SCRAM
Simulated Thermal Power · Single Recirc Loop Operation |
> = 0.65(W - 7.6) + 61.5%
(Reactor Mode Switch in "RUN") |
|
PRNMS SCRAM
Simulated Thermal Power · Clamped |
116.6%
(Reactor Mode Switch in "RUN") |
|
PRNMS SCRAM
Inoperative |
Critical self-test fault
Chassis mode switch in "INOP" Watchdog timer times out Loss of both power supplies to APRM channel |
|
PRNMS SCRAM
OPRM · Period Based Detection Algorithm (PBDA) |
> = 14 counts and > = 1.12 amplitude (see COLR)
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
PRNMS SCRAM
OPRM · Amplitude Based Algorithm (ABA) |
> = 1.30
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
PRNMS SCRAM
OPRM · Growth Rate Based Algorithm (GRBA) |
> =1.30
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
"PRNMS ROD WITHDRAWAL BLOCK
APRM Channel Trouble" |
< 3 LPRM detector input signals per axial level
< 20 total LPRM detector input signals to associated APRM channel Any Critical or Non-Critical Self-Test Fault detected in the APRM or LPRM chassis Loss of either of the redundant power supplies to the APRM channel (*AY185 or *BY185) |
|
PRNMS Alarms
OPRM Alarm · Period Based Detection Algorithm (PBDA) |
> = 14 counts
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
PRNMS Alarms
OPRM Alarm · Amplitude Based Algorithm (ABA) |
> = 1.20
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
PRNMS Alarms
OPRM Alarm · Growth Rate Based Algorithm (GRBA) |
> =1.20
Active only when OPRMs are ENABLED: STP >= 29.5% AND Total Recirc Drive Flow < 60% AND Reactor Mode Switch in "RUN" |
|
RBM Rod Block Setpoint & when Active
LPSP |
> 121.5%
When STP% is above 28.1% AND Less then 63.1% |
|
RBM Rod Block Setpoint & when Active
IPSP |
> 116.5%
When STP% is above 63.1% AND Less then 83.1% |
|
RBM Rod Block Setpoint & when Active
LPSP |
>=111.0%
When STP% is above 83.1% |
|
RBM Rod Block Setpoint & when Active
Downscale |
< 5.0%
|
|
RBM Rod Block Setpoint & when Active
INOP |
• RBM chassis INOP/OPER Keylock Switch in the “INOP” position
• Number of operating LPRM detectors is less than the required minimum and a control rod is selected • More than one control rod is selected • Loss of input power • Critical self-test fault • Firmware watchdog timer timed out |