WE

What are the requirements of WEc3.2
WE Credit 3.2: Water Use Reduction: 30% Reduction

Employ strategies that in aggregate use 30% less water than the water use baseline calculated for
the building (not including irrigation) after meeting the Energy Policy Act of 1992 fixture
performance requirements. Calculations are based on estimated occupant usage and shall include
only the following fixtures (as applicable to the building): water closets, urinals, lavatory faucets,
showers and kitchen sinks.
WE

What are the requirements of WEc3.1
WE Credit 3.1: Water Use Reduction: 20% Reduction

Employ strategies that in aggregate use 20% less water than the water use baseline calculated for
the building (not including irrigation) after meeting the Energy Policy Act of 1992 fixture
performance requirements. Calculations are based on estimated occupant usage and shall include
only the following fixtures (as applicable to the building): water closets, urinals, lavatory faucets,
showers and kitchen sinks.
WE

What are the requirements of WEc2
WE Credit 2: Innovative Wastewater Technologies

Reduce potable water use for building sewage conveyance by 50% through the use of waterconserving
fixtures (water closets, urinals) or non-potable water (captured rainwater, recycled
greywater, and on-site or municipally treated wastewater).
OR
OPTION 2
Treat 50% of wastewater on-site to tertiary standards. Treated water must be infiltrated or used
on-site.
WE

What are the requirements of WEc1.2
WE Credit 1.2: Water Efficient Landscaping: No Potable Water
Use or No Irrigation

Achieve WE Credit 1.1.and:
Use only captured rainwater, recycled wastewater, recycled greywater, or water treated and
conveyed by a public agency specifically for non-potable uses for irrigation.
OR
Install landscaping that does not require permanent irrigation systems. Temporary irrigation
systems used for plant establishment are allowed only if removed within one year of
installation.
WE

What are the requirements of WEc1.1
WE Credit 1.1: Water Efficient Landscaping: Reduce by 50%

Reduce potable water consumption for irrigation by 50% from a calculated mid-summer baseline
case.
Reductions shall be attributed to any combination of the following items:
• Plant species factor
• Irrigation efficiency
• Use of captured rainwater
• Use of recycled wastewater
• Use of water treated and conveyed by a public agency specifically for non-potable uses