blind shaft elevators
Elevators serving the upper areas of a building in a shaft that is not equipped with the hoistway doors on the lower floors
curtain wall
Non bearing wall, built between piers or coulda for the enclosure if the structure but not supported at each story
fire sector branch
Defined as the fire floor and floor above
incident command post
Establish in the lobby which will enable the ic to exert central control over operations
plenum
An air compartment or chamber to which one or more ducts are connected. Usually between the suspended ceiling and under side of the floor above
forward staging area
Area established on the floor below the fire sector/branch to provide logistical support to the fire sector branch
search and evacuation group or branch
Sae. Position established above the fire sector branch to control and coordinate all search and evacuation operations in that area
class E high rise office building
75ft or more, fireproof, primarily occupied for business.
heavy weight construction
Before 1945
heavy weight construction
Before 1945
medium weight construction
1945-68. Fire towers required in these
lightweight construction
After 1968, has exterior curtain walls that leaves a space of 6-12 inches which require additional fire stopping . Fire towers not required
where is the processing of air usually done?
Floors of building where mechanical room is located
non circulating mode of hvac
OO cm oe open outside, close mixer, open exhaust
four step procedure for starting pumps using control panel
Knives cut big lips. Close knife switch, close circuit breaker, push starting button, move lever to desired position
bypass pump is open
8 inch riser loss of 25%, 6 inch riser loss 45%.
pump discharge pressure.
Floors 1-10 150psi, 11-20 200psi, goes up 50 every ten floors
how do you **** down pumps in building when given command?
Return pump position to lowest speed, push off button, open circuit breakers, open knife switch (off position), advise icp that pumps are off
10-76 high rise office
Second alarm is warranted for any visible fire or smoke emanating through exterior skin
fire sector supervisor
First floor below fire floor
incident command post
Bc channel 2, aide channel 1
search and evacuation group
Chief channel 3, aide channel 2
forward staging area
Bc 2, aide 1
icp
Lobby
forward triage area
Location on floor below the forward staging area
what shall engine companies bring with them to forward staging areas?
Scba for each member, standpipe kit and nozzle, length of hose per guy, spare scba cylinder for each member
ladder companies reporting to forward staging area
Scba for each member, 2 sets of fe tools and hooks, search and utility rope, spare scba for each member
who control all ventilation
The ic
can you augment the hvac system with our Ppv fans?
No
buildings that have a fixed stairwell pressurization system.
Shall be entered into cids
can you use fire towers as an attack stair?
No it could draw the heat as smoke of high pressure towards the low pressure stairwell
negative stack effect may occur when?
Outside temp is greater then inside
what shall the sae group supervisor be equipped with?
2 handie talkies, post radio, scba for all members assigned to sae, spare cylinder for each member assigned, floor diagram with pen and pad
what is sae group responsible for?
Floors above the fire sector branch. Fire sector branch is fire floor and one floor above
where is forward staging area?
2 floors below original fire floor
what does the fsa need?
2 handie talkies, post radio, forward staging log. Maintain at least 20 spare cylinders
forward triage area
Established by the ic within the building. On an environmentally safe area below forward staging area
what's found at the floor warden station?
Telephone handset , capability to activate a visual/audible alarm , 2 way voice comm with fire command station , announcements over loud speaker, handset In red box
first arriving truck
Determine elevator bank, obtain floor plan( if only 1 leave it there), obtain necessary keys, ensure icp staffed by fd member, proceed to 2 floors below fire,
1st truck arrival on fire floor
Determine fire location, heat smoke condition, life hazard, location if stairs and select correct one with standpipe in it as attack stairway, primary search, support engine
2nd arriving truck
Examine exterior of building, operate elevators, temp staff icp, assist in search and rescue of fire floor,
3rd arriving truck
Verify fire floor, elevators, 2 floors below, determine nber of stairs for fire floor, proceed to floor above fire via a stair other then attack, determine evacuation stairs,examine floor report to icp, communicate if people are in attack stairway above fire to withhold operayions
fourth arriving truck
Report to icp, bring extra scba cylinder, proceed to roof, stairway other then attack, primary search of top five floors, fire on floor not serviced by high rise bank used if in a blind shaft, can go to fire floor proceed to location below then use stairs other then attack, to roof.
greater alarms and special call trucks
Report to staging area
first engine
Remain at icp until truck verifies fire location, proceed to upper floor via elevator, stretch from floor below standpipe, operate
2nd engine
Report to ic, take post radio to provide comm between the lobby and fire sector, officer remains at outlet till hose line is operating at correct nozzle pressure
3rd and 4th engines
Operate similar amber to the first 2, protect first line, protect search and evac,
greater alarm engine companies
Report to icp lobby or if staffed the lobby control unit. Units without specific orders shall bring additional scba to lobby area. If not needed will be added to fsa