THREE CATEGORIES OF FUEL
RECOMMENDED
ALTERNATE
EMERGENCY
FUNCTIONS OF FUEL SYSTEM
METERING
TIMING
PRESSURIZING
ATOMIZING
INJECTING
SOLENOID VALVE (L102)
VAC:
Hz:
PHASE:
ENERGIZED BY WHAT CONTACTOR
120 VAC
60 Hz
1 PHASE
K13
SUCTION STRAINER MICRON

HOW OFTEN DO YOU CLEAN
50 MICRON

300 HOURS OR 6 MONTHS
FUEL TRANSFER PUMP GPM

DRIVEN BY WHAT MOTOR
VAC
9.5 GPM
115/208-240 VAC MOTOR
WHAT ARE THE 4 CONDITIONS THAT MUST BE MET FOR TRANSFER PUMP TO OPERATE
SHORE POWER
FUEL SWITCH IN AUTO OR HAND
FUEL LEVEL LOW ENOUGH FOR FL1 TO CALL FOR FUEL
CB121 AND CB122 CLOSED, S100 AND CB1 ON
HOW MANY FUEL FILTERS ARE THERE
FOUR EACH IN PARALLEL
HOW OFTEN IS THE FILTER CHANGED
300 HOURS OR 6 MONTHS
WHAT ARE THE SEVEN PARTS OF THE PT PUMP
GEAR PUMP
SCREEN FILTER
LOWER GOVERNOR
THROTTLE SHAFT
ELECTRIC GOVERNOR ACTUATOR
VARIABLE SPEED GOVERNOR
PT PUMP
WHAT IS THE PSI ON THE PT PUMP
173 - 194 PSI @ 1800 RPM
DESCRIBE THE FUEL FLOW STARTING WITH THE CUSTOMER TANK
DAY TANK
FILTERS
PT PUMP
EMERGENCY SHUTOFF VALVE
FUEL MANIFOLDS
FUEL INJECTORS
FUEL RETURN MANIFILD
10 LB CHECK VALVE
DAY TANK
FL-1
FL-2
FL-3
FL-4
ON
OFF
LOW
HIGH
DESCRIBE WHAT EACH DO
SS1
SS2
SS3
WHEN DO SS1 AND SS2 RESET
SS1 = 600 RPM DISCONNECT STARTERS
SS2 = 1200 ARM UNDER FREQ AND UNDER VOLTAGE
SS3 = 2200 RPM SHUTDOWN ENGINE UPON OVERSPEED
SS1 RESET 500 RPM
SS2 RESET 1100 RPM
WHAT IS THE MAXIMUM INLET RESCRICTION ON PT PUMP
4 IN WATER
WHAT IS THE MAXIMUM FUEL CONSUMPTION
55 GAL/HR @ RATED LOAD
WHEN DO YOU REPLACE/CLEAN FUEL STRAINER
300 HOURS OR 6 MONTHS
DESCRIBE THE FUEL FLOW STARTING WITH THE CUSTOMER TANK
DAY TANK
FILTERS
PT PUMP
EMERGENCY SHUTOFF VALVE
FUEL MANIFOLDS
FUEL INJECTORS
FUEL RETURN MANIFILD
10 LB CHECK VALVE
DAY TANK
TRANSFER FILTER

FUEL STRAINER
300 HOURS OR 6 MONTHS (BOTH)
FL-1
FL-2
FL-3
FL-4
ON
OFF
LOW
HIGH
DESCRIBE WHAT EACH DO
SS1
SS2
SS3
WHEN DO SS1 AND SS2 RESET
SS1 = 600 RPM DISCONNECT STARTERS
SS2 = 1200 ARM UNDER FREQ AND UNDER VOLTAGE
SS3 = 2200 RPM SHUTDOWN ENGINE UPON OVERSPEED
SS1 RESET 500 RPM
SS2 RESET 1100 RPM
WHAT IS THE MAXIMUM INLET RESCRICTION ON PT PUMP
4 IN WATER
WHAT IS THE MAXIMUM FUEL CONSUMPTION
55 GAL/HR @ RATED LOAD
WHEN DO YOU REPLACE/CLEAN FUEL STRAINER
300 HOURS OR 6 MONTHS
TRANSFER FILTER

FUEL STRAINER
300 HOURS OR 6 MONTHS (BOTH)