FIREGUARDS ARE REQUIRED TO
REDUCE THE THREAT OF FIRE IN A VARIETY OF LOCATION
WHEN ARE FIREGUARDS ARE USED
A SPRINKLER SYSTEM IS NOT INSTALLED
WHAT OTHER REASON WHEN FIREGUARDS ARE USED
WHEN AN AUTOMATIC FIRE SYSTEMS ARE SHUT DOWN OR BEING REPAIRED
FIREGUARDS ARE RESPONSIBLE
MAKING SURE FIRE SAFETY REGULATIONS ARE OBEYED
FIREGUARDS HAVE GOOD WORKING KNOWLEDGE
BASIC FIRE FIGHTING AND FIRE PROTECTION TECHNIQUES
FIREGUARDS MUST KNOW THE LOCATIONS
ALL FIRE PROTECTION DEVICES
WHAT ARE MAIN TYPES FIRE PULL STATIONS
TWO INTERIOR AND EXTERIOR PULL STATIONS
AN INTERIOR PULL STATION IS REQUIRED EACH FLOOR NEAR
THE NATURAL EXITS OF EACH FLOOR OF BLULDING
IN LARGER BLDGS THE FIRE PULL STATION ARE LOCATED
SPACED AND THE DISTANCED BE STATION NOT EXCEEDED 200 FEET AND MOUNTED ON THE WALL 3.5 TO 5 FEET ABOVE FLOOR LEVEL
THERE ARE TWO KINDS OF PULL STATIONS WHAT ARE THEY
SINGLE ACTION AND DOUBLE ACTION
WHAT IS REQUIRED TO ACTIVATE A SINGLE ACTION PULL STATIONS
1ST STEP TO ACTIVATE: PULL LEVER OR BREAKING GLASS
WHERE ARE SINGLE ACTION PULL STATION FOUND
PULL STATION IS ALLOWED IN DOORS MOSTLY IN OFFICE BLDGS
TO SHUTOFF A ACTIVE ALARM YOU MUST USE A
SPECIAL KEY LOCATED NEAR THE CONTROL PANEL
THE BULLHORN AND WALKIE TALKIE MUST BE INSPECTED WHEN
BEFORE MAKING EACH PATROL
IN SOME LOCATIONS A FIREGUARD IS EQUIPED WITH
WALKIE-TALKIE AND/OR BULLHORN
DURING A FIRE EMERGENCY A FIREGUARD MUST REMAIN
COMPOSED AND IN CONTROL OF SITUATION
THE BEST WAY TO PUT A FIRE IS TO SPRAY THE WATER FROM THE SPRINKLER HEAD
DOWNWARD AND HORIZONTALLY
WHERE WET PIPE SYSTEMS CANNOT BE HEATED TO PREVENT FREEZING
WHERE ARE DRY PIPE SPRINKLER OR DRY STANDPIPE SYSTEMS ARE INSTALLED
THE PIPING SYSTEM IS FILL WITH AIR PRESSURE
IN STANDPIPE SYSTEMS , IN NORMAL CONDITIONS THERE IS NO WATER IN THE PIPING WHAT IS IT FILL WITH
AUTOMATICALLY BY AN AIR MAINTENANCE DEVICE
IN STANDPIPE STSTEMS,,THE AIR PRESSURE IN THE SYSTEM ISCONTROLLED
SPRINKLER HEADS OR HOSES AND NOZZLES
THE STANDPIPE SYSTEM USE STANDARDS
HEAT FROM FIRE OR A NOZZLE IS MANUALLY OPENED .THE AIR PRESURE IS REDUCED IN THE PIPING
WHEN A SPRINKLER HEAD IS OPENED BY
TRUE
IN A STANDPIPE SYSTEM, WHEN THE VALVE IS OPENED A SUPERVISORY DEVICE IS SINGALLED TRUE OR FALSE
SOUNDS A LOCAL ALARM TO ALERT THE OCCUPANTS IN THE BLULDING
IN A STANDPIPE SYSTEM, WHEN A WATER FLOW DOES WHAT
CENTRAL STATION COMPANY
IN A STANDPIPE SYSTEM, THE ALARM IS TRANSMITTED TO A
NOTIFY THE FIRE DEPARTMENT THERE IS A FIRE
WHEN A CENTRAL STATION IS ALERTED IT WILL
THE FIRE DEPARTMENT IS DIRECTLY TO THE FIRE DEPARTMENT
IN BLULDINGS WHERE LIFE HAZARD IS VERY HIGH
WHAT BLULDINGS ARE EXAMPLES WHERE LIFE HARZARD IS VERY HIGH
school and hospitals
ONCE A MONTH
PORTABLE FIRE EXTINGUISHERS MUST BE INSPECTED AT LEAST
ONCE A YEAR
PORTABLE FIRE EXTINGUISHERS MUST BE TESTED AT LEAST
THE TEST IS PERFORMED BY A CERTIFIED COMPANY OR AND INDIVIDUAL HOLDING A CERTIFICATE OF FITNESS FOR THIS PURPOSE
WHEN A PORTABLE FIRE EXTINGUISHERS IS BEING TESTED ANNUALLY AND MAYBE RECHARGED
ONCE A MONTH
PORTABLE FIRE EXTINGUISHERS MUST BE IINSPECTED AT
YEAR
PORTABLE FIRE EXTINGUISHERS MUST BE TESTED AT LEAST
A CERTIFIED COMPANY OR PERSON HOLDING A CERTIFICATE OF FITNESS FOR THIS PURPOSE
IN PORTABLE FIRE EXTINGUISHERS, THE ANNNUAL TEST AND RECHARGING MUST BE PERFORMED BY
RECORDED IN THE INSPECTION LOG
WITH PROTABLE FIRE EXTINGUISHERS, THE FIREGUARD MUST MAKE SURE THAT ALL INSPECTIONS AND TESTS ARE
DAILY
THE FIREGUARD MUST CONDUCT A VISUAL INSPECTION OF ALL PORTABLE FIRE EXTINGUISHERS
IN A CORRECT POSITION AND CLEARLY VISIBLE
THE FIREGUARD MUST MAKE SURE PORTABLE FIRE EXTINGUISHERS POSITIONED
RAISED THE VALVE IS OPEN
THE POSITION OF THE SPRINKLER /STANDPIPE SYSTEM VALVE IS
TRUE
WHEN THE STEM OF A OS&Y VALVE IS NOT RAISED THE VALVE IS CLOSED TRUE/FALSE
ANNUALLY BY A QUALIFIED TECHNICIAN
BOTH THE SPRINKLER AND THE STANPIPE SYSTEM MUST BE INSPECTED
A CERTIFICATE OF FITNESS FOR THE INSPECTION OF SPRINKLER AND STANDPIPE SYSTEMS
THE TECHNICIAN WHO MAKES THE ANNUAL INSPECTIONS MUST HOLD
24 HOURS ADAY WHEN THE FIRE ALARM ,OR SPRINKLER SYSTEM IS INSTALLED OR IS OUT OF SERVICE
IN HOTELS AND MOTELS, A FIREGUARD MUST BE ON DUTY
THE FIRE SAFETY DIRECTOR AND THE FIRE DEPARTMENT DURING FIRE EMERGENCIES
IN HOTELS AND MOTELS, THE FIRE WARDENS ,ASSIST
TRAINED VOLUNTEERS PROVIDED BY THE TENANTS IN THE BUILDING
IN HOTELS AND MOTELS, FIRE WARDENS AND DEPUTY FIRE WARDENS ARE
HAS 15 SLEEPING ROOMS OR 15 LODGERS ABOVE THE FIRE FLOOR OR 30 SLEEPING ROOMS OR 30 SLEEPING ROOMS IN THE BUILDING
FIRE SAFETY REGULATIONS FOR HOTELS AND MOTELS APLLY WHEN A BUILDING
THIS PLAN GIVES A DETAILED DESCRIPTION OF WHAT MUST BE DONE IN CASE OF A FIRE EMERGENCY AND MUST BE APPROVED BY THE FIRE DEPARTMENT
IN HOTELS AND MOTELS, WHAT IS A FIRE SAFETY PLAN
BY ALL EMPLOYEES AND TENANTS
IN HOTELS AND MOTELS , A COPY OF THE FIRE SAFETY PLAN MUST BE DISTRIBUTED
SEVERAL LOCATIONS
IN HOTELS AND MOTELS , EMERGENCY INSTRUCTIONS FROM THE PLAN SHOULD BE POSTED
FIRE SAFETY DIRECTOR
IF ANY VIOLATIONS ARE DISCOVERED THE FIRE GUARD MUST REPORT THEM THE
ARE STORED IN A SAFE AREA
THE FIREGUARD MUST MAKE SURE THAT ALL COMBUSTIBLE CLEANING AGENTS , PAINTS , ETC
FROM POTENTIAL SOURCES OF IGNITION
FOR COMBUSTIBLE CLEANING AGENTS, THIS STORAGE AREA PROTECT THE MATERIALS
SOME EXITS ARE FITTED WITH
PANIC BARS
THE PANIC BARS ALLOW THE DOOR TO BE OPENED EASILY BY PRESSING ON THE BAR
HOW DOES PANIC BARS WORK
SMOKE DETECTORS
FIREGUARD MUST MAKE SURE ----------------------ARE INSTALLED THROUGHOUT THE BUILDING
TRUE
FIREGUARD MUST TAKE PART IN ALL FIRE DRILL EXERCISES HELD IN THE BUILDING TRUE OR FALSE
THE FIRE DRILL CONDUCTOR DURING THE FIRE DRILL
IN DRILL EXERCISES, THE FIREGUARD MUST ASSIST
AND THEREAFTER FIRE DRILLS CAN BE CONDUCTED ONCE EVERY SIX MONTHS
IN HOTELS/MOTELS, A FIRE DRILL MUST BE CONDUCTED
RECORDED IN THE FIREGUARD'S LOG
IN HOTELS /MOTELS ALL FIRE DRILLS MUST BE
TO ANY REPRESENTATIVE FROM THE FIRE DEPARTMENT
FIREGUARD LOG'S MUST BE AVAILABLE
STAIRWAYS IN THE BUILDINGS
IN HOTELS /MOTELS SPECIAL ATTENTION MUST BE PAID
PERMITED ON EVERY FOURTH FLOOR
IN BUILDINGS LESS THAN 100 FEET IN HEIGHT REENTRY FROM THE STAIRWAY
REENTRY FROM THE STAIRWAY IS NOT REQUIRED
IN HOTELS, BLULDINGS LESS THAN 100 FEET IN HEIGHT
FIREGUARD
IN HOTELS, A DAILY INSPECTION LOG MUST BE MAINTAINED BY THE
1. NUMBER OF INSPECTIONS 2. DEFECTS DISCOVERED 3, VIOLATIONS THAT HAVE BEEN NOTICED 4. THE DATE ,SIGNATURE OF FIREGUARD WHO CONDUCTED THE INSPECTONS
IN HOTELS , IN A DAILY INSPECTION LOG THE FOLLOWING ITEMS MUST BE RECORDED
WITH A WALKIE AND BULLHORN
IN HOTELS , EACH FIRE GUARD MUST BE EQUIPPED
LOG IN BOOK EVERY STATUS, AND STATUS OF SAFETY DEVICES
MY PERSONAL FIREGUARD STRATEGY IS
`TRUE
IN HOTELS , SAFETY SIGNS MUST BE POSTED AT SEVERAL LOCATIONS THROUGHOUT THE BLULDING TRUE OR FALSE
INSIDE THE STAIRWAYS AND NEXT TO EACH ELEVATOR
IN HOTELS, A SAFE4TY SIGN BE POSTED ON EVERY FLOOR
THE SIGN MAKE IT EASY FOR FIRE DEPARTMENT PERSONNEL TO IDENTIFY THE QUICKEST ROUTE TO A FIRE
A SIGN "FLOOR 12 ,ELEVATOR A" WHAT IS THE REASON FOR THIS SIGN
THE SIGN MUST INDICATE THAT THE ELEVATOR MUST NOT BE USED IN CASE OF AN EMERGENCY
IN HOTELS , WHAT WILL A SIGN SAY IF IT IS POSTED ON EVERY FLOOR AT THE ELEVATOR LANDING
" IN CASE OF FIRE ,USE STAIRS UNLESS OTHERWISE INSTRUCTED"
IN HOTELS, IS THE EXAMPLE OF WHAT A ELEVATOR LANDING SIGN SAY.
THE LOCATION OF THE STAIRWAYS ON THE FLOOR
IN HOTELS , ELEVATOR SIGNS MUST INDICATE
WHETHER ENTRY TO THE BUILDING IS PERMITTED FROM THE FLOOR
IN HOTELS , A SIGN MUST INDICATE
THE NUMBER OF THE FLOOR WHERE ENTRY IS PERMITTED FOR EXAMPLE " RE-ENTRY ON THE FLOOR or "NO RE-ENTRY NEAREST RE-ENTRY ON 7TH AND 10TH FLOORS
IN HOTELS IN ENTRY IS NOT PERMITTED A SIGN MUST
24 HOURS A DAY
IN MARINA /F92 IS USE FOR OVERNIGHT OCCUPANCY AT LEAST ONE FIREGUARD IS REQUIRED
DEPENDING ON THE SIZE OF THE MARINA
IN MARINA /F92 .ADDITIONAL FIREGUARDS MY BE REQUIRED
FIREGUARDS ARE REQUIRED TO
REDUCE THE THREAT OF FIRE IN A VARIETY OF LOCATION
WHEN ARE FIREGUARDS ARE USED
A SPRINKLER SYSTEM IS NOT INSTALLED
WHAT OTHER REASON WHEN FIREGUARDS ARE USED
WHEN AN AUTOMATIC FIRE SYSTEMS ARE SHUT DOWN OR BEING REPAIRED
FIREGUARDS ARE RESPONSIBLE
MAKING SURE FIRE SAFETY REGULATIONS ARE OBEYED
FIREGUARDS HAVE GOOD WORKING KNOWLEDGE
BASIC FIRE FIGHTING AND FIRE PROTECTION TECHNIQUES
FIREGUARDS MUST KNOW THE LOCATIONS
ALL FIRE PROTECTION DEVICES
WHAT ARE MAIN TYPES FIRE PULL STATIONS
TWO INTERIOR AND EXTERIOR PULL STATIONS
AN INTERIOR PULL STATION IS REQUIRED EACH FLOOR NEAR
THE NATURAL EXITS OF EACH FLOOR OF BLULDING
IN LARGER BLDGS THE FIRE PULL STATION ARE LOCATED
SPACED AND THE DISTANCED BE STATION NOT EXCEEDED 200 FEET AND MOUNTED ON THE WALL 3.5 TO 5 FEET ABOVE FLOOR LEVEL
THERE ARE TWO KINDS OF PULL STATIONS WHAT ARE THEY
SINGLE ACTION AND DOUBLE ACTION
WHAT IS REQUIRED TO ACTIVATE A SINGLE ACTION PULL STATIONS
1ST STEP TO ACTIVATE: PULL LEVER OR BREAKING GLASS
WHERE ARE SINGLE ACTION PULL STATION FOUND
PULL STATION IS ALLOWED IN DOORS MOSTLY IN OFFICE BLDGS
TO SHUTOFF A ACTIVE ALARM YOU MUST USE A
SPECIAL KEY LOCATED NEAR THE CONTROL PANEL
THE BULLHORN AND WALKIE TALKIE MUST BE INSPECTED WHEN
BEFORE MAKING EACH PATROL
IN SOME LOCATIONS A FIREGUARD IS EQUIPED WITH
WALKIE-TALKIE AND/OR BULLHORN
DURING A FIRE EMERGENCY A FIREGUARD MUST REMAIN
COMPOSED AND IN CONTROL OF SITUATION
DOWNWARD AND HORIZONTALLY
THE BEST WAY TO PUT OUT A FIRE IS TO SPRAY THE WATER FROM THE SPRINKLER HEAD
WHERE WET PIPE SYSTEMS CANNOT BE HEATED TO PREVENT FREEZING
WHERE ARE DRY PIPE SPRINKLER OR DRY STANDPIPE SYSTEMS ARE INSTALLED
THE PIPING SYSTEM IS FILL WITH AIR PRESSURE
IN STANDPIPE SYSTEMS , IN NORMAL CONDITIONS THERE IS NO WATER IN THE PIPING WHAT IS IT FILL WITH
AUTOMATICALLY BY AN AIR MAINTENANCE DEVICE
IN STANDPIPE STSTEMS,,THE AIR PRESSURE IN THE SYSTEM ISCONTROLLED
SPRINKLER HEADS OR HOSES AND NOZZLES
THE STANDPIPE SYSTEM USE STANDARDS
HEAT FROM FIRE OR A NOZZLE IS MANUALLY OPENED .THE AIR PRESURE IS REDUCED IN THE PIPING
WHEN A SPRINKLER HEAD IS OPENED BY
TRUE
IN A STANDPIPE SYSTEM, WHEN THE VALVE IS OPENED A SUPERVISORY DEVICE IS SINGALLED TRUE OR FALSE
SOUNDS A LOCAL ALARM TO ALERT THE OCCUPANTS IN THE BLULDING
IN A STANDPIPE SYSTEM, WHEN A WATER FLOW DOES WHAT
CENTRAL STATION COMPANY
IN A STANDPIPE SYSTEM, THE ALARM IS TRANSMITTED TO A
NOTIFY THE FIRE DEPARTMENT THERE IS A FIRE
WHEN A CENTRAL STATION IS ALERTED IT WILL
THE FIRE DEPARTMENT IS DIRECTLY TO THE FIRE DEPARTMENT
IN BLULDINGS WHERE LIFE HAZARD IS VERY HIGH
SCHOOLS AND HOSPITALS
WHAT BLULDINGS ARE EXAMPLES WHERE LIFE HARZARD IS VERY HIGH
ONCE A MONTH
PORTABLE FIRE EXTINGUISHERS MUST BE INSPECTED AT LEAST
ONCE A YEAR
PORTABLE FIRE EXTINGUISHERS MUST BE TESTED AT LEAST
THE TEST IS PERFORMED BY A CERTIFIED COMPANY OR AND INDIVIDUAL HOLDING A CERTIFICATE OF FITNESS FOR THIS PURPOSE
WHEN A PORTABLE FIRE EXTINGUISHERS IS BEING TESTED ANNUALLY AND MAYBE RECHARGED
ONCE A MONTH
PORTABLE FIRE EXTINGUISHERS MUST BE IINSPECTED AT
YEAR
PORTABLE FIRE EXTINGUISHERS MUST BE TESTED AT LEAST
A CERTIFIED COMPANY OR PERSON HOLDING A CERTIFICATE OF FITNESS FOR THIS PURPOSE
IN PORTABLE FIRE EXTINGUISHERS, THE ANNNUAL TEST AND RECHARGING MUST BE PERFORMED BY
RECORDED IN THE INSPECTION LOG
WITH PROTABLE FIRE EXTINGUISHERS, THE FIREGUARD MUST MAKE SURE THAT ALL INSPECTIONS AND TESTS ARE
DAILY
THE FIREGUARD MUST CONDUCT A VISUAL INSPECTION OF ALL PORTABLE FIRE EXTINGUISHERS
IN A CORRECT POSITION AND CLEARLY VISIBLE
THE FIREGUARD MUST MAKE SURE PORTABLE FIRE EXTINGUISHERS POSITIONED
RAISED THE VALVE IS OPEN
THE POSITION OF THE SPRINKLER /STANDPIPE SYSTEM VALVE IS
TRUE
WHEN THE STEM OF A OS&Y VALVE IS NOT RAISED THE VALVE IS CLOSED TRUE/FALSE
ANNUALLY BY A QUALIFIED TECHNICIAN
BOTH THE SPRINKLER AND THE STANPIPE SYSTEM MUST BE INSPECTED
A CERTIFICATE OF FITNESS FOR THE INSPECTION OF SPRINKLER AND STANDPIPE SYSTEMS
THE TECHNICIAN WHO MAKES THE ANNUAL INSPECTIONS MUST HOLD
24 HOURS ADAY WHEN THE FIRE ALARM ,OR SPRINKLER SYSTEM IS INSTALLED OR IS OUT OF SERVICE
IN HOTELS AND MOTELS, A FIREGUARD MUST BE ON DUTY
THE FIRE SAFETY DIRECTOR AND THE FIRE DEPARTMENT DURING FIRE EMERGENCIES
IN HOTELS AND MOTELS, THE FIRE WARDENS ,ASSIST
TRAINED VOLUNTEERS PROVIDED BY THE TENANTS IN THE BUILDING
IN HOTELS AND MOTELS, FIRE WARDENS AND DEPUTY FIRE WARDENS ARE
HAS 15 SLEEPING ROOMS OR 15 LODGERS ABOVE THE FIRE FLOOR OR 30 SLEEPING ROOMS OR 30 SLEEPING ROOMS IN THE BUILDING
FIRE SAFETY REGULATIONS FOR HOTELS AND MOTELS APLLY WHEN A BUILDING
THIS PLAN GIVES A DETAILED DESCRIPTION OF WHAT MUST BE DONE IN CASE OF A FIRE EMERGENCY AND MUST BE APPROVED BY THE FIRE DEPARTMENT
IN HOTELS AND MOTELS, WHAT IS A FIRE SAFETY PLAN
BY ALL EMPLOYEES AND TENANTS
IN HOTELS AND MOTELS , A COPY OF THE FIRE SAFETY PLAN MUST BE DISTRIBUTED
SEVERAL LOCATIONS
IN HOTELS AND MOTELS , EMERGENCY INSTRUCTIONS FROM THE PLAN SHOULD BE POSTED
FIRE SAFETY DIRECTOR
IF ANY VIOLATIONS ARE DISCOVERED THE FIRE GUARD MUST REPORT THEM THE
ARE STORED IN A SAFE AREA
THE FIREGUARD MUST MAKE SURE THAT ALL COMBUSTIBLE CLEANING AGENTS , PAINTS , ETC
FROM POTENTIAL SOURCES OF IGNITION
FOR COMBUSTIBLE CLEANING AGENTS, THIS STORAGE AREA PROTECT THE MATERIALS
PANIC BARS
SOME FIRE EXITS ARE FITTED WITH
THE PANIC BARS ALLOW THE DOOR TO BE OPENED EASILY BY PRESSING ON THE BAR
HOW DOES PANIC BARS WORK
SMOKE DETECTORS
FIREGUARD MUST MAKE SURE ----------------------ARE INSTALLED THROUGHOUT THE BUILDING
TRUE
FIREGUARD MUST TAKE PART IN ALL FIRE DRILL EXERCISES HELD IN THE BUILDING TRUE OR FALSE
THE FIRE DRILL CONDUCTOR DURING THE FIRE DRILL
IN DRILL EXERCISES, THE FIREGUARD MUST ASSIST
AND THEREAFTER FIRE DRILLS CAN BE CONDUCTED ONCE EVERY SIX MONTHS
IN HOTELS/MOTELS, A FIRE DRILL MUST BE CONDUCTED
RECORDED IN THE FIREGUARD'S LOG
IN HOTELS /MOTELS ALL FIRE DRILLS MUST BE
TO ANY REPRESENTATIVE FROM THE FIRE DEPARTMENT
FIREGUARD LOG'S MUST BE AVAILABLE
STAIRWAYS IN THE BUILDINGS
IN HOTELS /MOTELS SPECIAL ATTENTION MUST BE PAID
PERMITED ON EVERY FOURTH FLOOR
IN BUILDINGS LESS THAN 100 FEET IN HEIGHT REENTRY FROM THE STAIRWAY
REENTRY FROM THE STAIRWAY IS NOT REQUIRED
IN HOTELS, BLULDINGS LESS THAN 100 FEET IN HEIGHT
FIREGUARD
IN HOTELS, A DAILY INSPECTION LOG MUST BE MAINTAINED BY THE
1. NUMBER OF INSPECTIONS 2. DEFECTS DISCOVERED 3, VIOLATIONS THAT HAVE BEEN NOTICED 4. THE DATE ,SIGNATURE OF FIREGUARD WHO CONDUCTED THE INSPECTONS
IN HOTELS , IN A DAILY INSPECTION LOG THE FOLLOWING ITEMS MUST BE RECORDED
WITH A WALKIE AND BULLHORN
IN HOTELS , EACH FIRE GUARD MUST BE EQUIPPED
LOG IN BOOK EVERY STATUS, AND STATUS OF SAFETY DEVICES
MY PERSONAL FIREGUARD STRATEGY IS
`TRUE
IN HOTELS , SAFETY SIGNS MUST BE POSTED AT SEVERAL LOCATIONS THROUGHOUT THE BLULDING TRUE OR FALSE
INSIDE THE STAIRWAYS AND NEXT TO EACH ELEVATOR
IN HOTELS, A SAFE4TY SIGN BE POSTED ON EVERY FLOOR
THE SIGN MAKE IT EASY FOR FIRE DEPARTMENT PERSONNEL TO IDENTIFY THE QUICKEST ROUTE TO A FIRE
A SIGN "FLOOR 12 ,ELEVATOR A" WHAT IS THE REASON FOR THIS SIGN
THE SIGN MUST INDICATE THAT THE ELEVATOR MUST NOT BE USED IN CASE OF AN EMERGENCY
IN HOTELS , WHAT WILL A SIGN SAY IF IT IS POSTED ON EVERY FLOOR AT THE ELEVATOR LANDING
" IN CASE OF FIRE ,USE STAIRS UNLESS OTHERWISE INSTRUCTED"
IN HOTELS, IS THE EXAMPLE OF WHAT A ELEVATOR LANDING SIGN SAY.
THE LOCATION OF THE STAIRWAYS ON THE FLOOR
IN HOTELS , ELEVATOR SIGNS MUST INDICATE
WHETHER ENTRY TO THE BUILDING IS PERMITTED FROM THE FLOOR
IN HOTELS , A SIGN MUST INDICATE
THE NUMBER OF THE FLOOR WHERE ENTRY IS PERMITTED FOR EXAMPLE " RE-ENTRY ON THE FLOOR or "NO RE-ENTRY NEAREST RE-ENTRY ON 7TH AND 10TH FLOORS
IN HOTELS IN ENTRY IS NOT PERMITTED A SIGN MUST
24 HOURS A DAY
IN MARINA /F92 IS USE FOR OVERNIGHT OCCUPANCY AT LEAST ONE FIREGUARD IS REQUIRED
DEPENDING ON THE SIZE OF THE MARINA
IN MARINA /F92 .ADDITIONAL FIREGUARDS MY BE REQUIRED