What are the 4 types of sprinkler systems?
|
wet pipe, dry pipe, preaction, deluge
|
|
What is a wet pipe sprinkler system? (advantages)
|
Most common quick reaction, system that exists only works well in environments over 40 degrees F
|
|
What is a dry pipe sprinkler system? (advantages/disadvantages)
|
Activated by air or nitro, delayed, works well in environments under 40 degrees f
Issue is when you charge a dry system it's more likely to leak out of any open outlets or ports. |
|
What is a pre-action sprinkler system?
|
closed heads, responds only to initiating device good for communications/computer systems
|
|
What is a deluge system?
|
All heads open when valve is opened, perfect for high risk environements
|
|
What is a Class 1 stand pipe? (GPM & use)
|
500gpm and only 2 1/2 connection for fire personnel
|
|
What is a Class 2 stand pipe? (GPM & use)
|
100gpm, contains 1 1/2 connection for occupants (wet) w/ 50 psi nozzle
|
|
What is a class 3 system?
(GPM & use) |
500gpm has 1/1/2 hose and nozzle but also has 2 1/2 connections for fire personnel and occupants.
|
|
If a system is charged but won't turn off at the PIV? where should you shut it off? and why?
|
turn it off at the riser and drain that line because if you turn off the os&y it'll turn off all the water to the building
|
|
What should you pump an FDC at?
|
150gpm w/ a minimum of 2 2 1/2 inch hose lines
|
|
What is temperature rating for an ordinary sprinkler head that's not colored?
|
135-175 degrees
|
|
What's the normal range of the average sprinkler head?
|
15-20ft
|
|
What is the name of the bulb in a sprinkler?
|
frangible bulb
|
|
When is an OS&Y valve open?
|
when the screw is completely visible
|
|
What is the most common sprinkler head?
|
pendant
|
|
What is a frangibile bulb?
|
it's a bulb filled with liquid with a little air bubble when it reaches a certain temperature that bubble evaporates into the liquid and the liquid expands.
|
|
What does the color of a sprinkler head indicate?
|
the heat/temperature it'll activate at.
|
|
What are out of ground sprinkler system?
|
risers
|
|
What should a PIV read?
|
open and it should be locked or chained
|
|
What is a type 1 building construction called?
|
Fire resistive
|
|
What is a type 2 building construction called?
|
Noncombustible
|
|
What does a pendant sprinkler mean?
|
Facing down Meaning that the water just flows straight down.... where as with an upright sprinkler it sprays up and is deflected down.
|
|
How much clearance must you have from a sprinkler head?
|
18 inches
|
|
What is a type 3 building construction called?
|
Ordinary
|
|
What is a type 4 building construction called?
|
Heavy timber
|
|
What is a type 5 building construction called?
|
Wood Frame
|