What are the 4 types of sprinkler systems?
wet pipe, dry pipe, preaction, deluge
What is a wet pipe sprinkler system? (advantages)
Most common quick reaction, system that exists only works well in environments over 40 degrees F
What is a dry pipe sprinkler system? (advantages/disadvantages)
Activated by air or nitro, delayed, works well in environments under 40 degrees f
Issue is when you charge a dry system it's more likely to leak out of any open outlets or ports.
What is a pre-action sprinkler system?
closed heads, responds only to initiating device good for communications/computer systems
What is a deluge system?
All heads open when valve is opened, perfect for high risk environements
What is a Class 1 stand pipe? (GPM & use)
500gpm and only 2 1/2 connection for fire personnel
What is a Class 2 stand pipe? (GPM & use)
100gpm, contains 1 1/2 connection for occupants (wet) w/ 50 psi nozzle
What is a class 3 system?
(GPM & use)
500gpm has 1/1/2 hose and nozzle but also has 2 1/2 connections for fire personnel and occupants.
If a system is charged but won't turn off at the PIV? where should you shut it off? and why?
turn it off at the riser and drain that line because if you turn off the os&y it'll turn off all the water to the building
What should you pump an FDC at?
150gpm w/ a minimum of 2 2 1/2 inch hose lines
What is temperature rating for an ordinary sprinkler head that's not colored?
135-175 degrees
What's the normal range of the average sprinkler head?
15-20ft
What is the name of the bulb in a sprinkler?
frangible bulb
When is an OS&Y valve open?
when the screw is completely visible
What is the most common sprinkler head?
pendant
What is a frangibile bulb?
it's a bulb filled with liquid with a little air bubble when it reaches a certain temperature that bubble evaporates into the liquid and the liquid expands.
What does the color of a sprinkler head indicate?
the heat/temperature it'll activate at.
What are out of ground sprinkler system?
risers
What should a PIV read?
open and it should be locked or chained
What is a type 1 building construction called?
Fire resistive
What is a type 2 building construction called?
Noncombustible
What does a pendant sprinkler mean?
Facing down Meaning that the water just flows straight down.... where as with an upright sprinkler it sprays up and is deflected down.
How much clearance must you have from a sprinkler head?
18 inches
What is a type 3 building construction called?
Ordinary
What is a type 4 building construction called?
Heavy timber
What is a type 5 building construction called?
Wood Frame