____ ____ are test conducted after a fire apparatus has been put into service to determine if its performance meets predetermined specifications ar standards.
Performance Test

pg 330
pump ops
NFPA 1901 calls for annual _____ _____ of fire apparatus pumps. Fire pump are water pumps with a rated capacity of 250 GPM or greater at 150 psi net pump pressure that are mounted on a fire apparatus and used for firefighting purposes.
Servic Testing

pg 330
pump ops
The performance tests for fire pumps do not just test the pump; they test the netire pumping system which includes the following: (4)
1. The engine
2. Transmission
3. Pump
4. related accessories and devices used in operating the pumping system

pg 330
pump ops
Which NFPA regulates the actual conduct of the performance testing of fire pumps?
NFPA 1911, Standard for the Inpection, Testing, and Retirement of In-Service Automotive Fire Apparatus

pg 330
pump ops
Engine-driven accessories should not be functionally disconnected or otherwise rendered inoperative during the annual performance test. The following devices are permitted to be turned off or at least not operated during the pump performance test: (7)
1. Aerial Hydraulic pump
2. Foam Pump
3. Hydraulic-driven equipment (other than a hydraulic driven line voltage generator)
4. Winch
5. Windshield wipers
6. Four-way hazard flashers
7. Compressed-air foam system compressor

pg 331
pump ops
When conducting performance tests on fire pumps, the fire apparatus should use the _____ ____ only. Although not preferred, front- or rear-mounted intakes may be used in conjuction with side intakes suction(s) for all pumps that provide flows of ____ GPM or greater.
Side Intakes should only be used

Front- or Rear-mounted intakes may used for pump with flow of 1500 GPM or greater

pg 331
pump ops
______ is defined as a cessation of proper functioning or performance. Other defects in the performance of the engine or the pump should be documented as well, and minor defects should be corrected immediately if possible.
Failure

pg 331
pump ops
Prior to the commencement of any performance tests on fire apparatus pumps, the following environmental conditions must be determined and recorded prior to and immediately agter the pump performance testing: (3)
1. Ambient air temperature
2. Water Temperature
3. Atmospheric pressure

pg 331
pump ops
NFPA 1911 specifies that tests must be conducted when the ambient air temp is between ___ F and ___ F.
0 degrees F and 110 degrees F

pg 331
pump ops
______ ____ ____ is the temperature of the surrounding medium and usually refers to the temperature of the air in which a structure is situated or a device operates.
Ambient air temperature

pg 331
pump ops
NFPA 1911 specifies that water temperature should be between ___ degrees F and ___ degrees F.
35 to 90 degrees F

pg 331
pump ops
Water temperature extrems are even more important. Warm water, usually defined as water at a temperature greater than ___F is more likely to _______ inside the pump and may result in a loss of up to ____ GPM in flow rate.
>90 degrees F
>is more likely to cavitate inside the pump
> up to 500 GPMs in flow rate

pg 331
pump ops
To correct local atmospheric pressure readings to sea level, add __ inche(s) of Hg for every ____' of elevation at the site.
1 inch of Mercury for every 1000' of elevation

pg 331
pump ops
The test site should be located along an improved roadway or on solid ground where the water is from __' to __' below grade.
4' to 8' below grade

pg 331
pump ops
It should be possible to reach the water from the pump intake with not more __' of hard suction hose with the strainer submerged at least 2' and with no humps in the hose.
20' of hard suction

pg 331-332
pump ops
A poor test site can result in as much as ___ to ___ GPM of lost flow rate.
150 to 500 GPM of lost flow rate

pg 332
pump ops
The ____ ____ _____ is an organizaiton, office, or indivdual responsible for enforcing the requirements of a code or standard, or for approving equipment, materials,an installation , or a prcedure.
Authority having Jurisdiction (AHJ)

pg 332
pump ops
The lift is the vertical height that water must be raised during a drafitng operation, as measured from the ?
from the surface of a static source of water to the center line of the pump intake.

pg 332
pump ops
The maximum lift is the greates difference in elevation at which the fire apparatus can draft the required quantity of water under te established physical characterstics of the operation. These characteristics will take into account the following consederations: (7)
1. The design of the pump
2. The adequacy of the engine
3. The condition of the pump and the engine
4. The size and condition of the suction hose and strainers
5. The elevation of the pumping site above sea level
6. The atmoshperic conditions
7. The temperature of the water

pg 332
pump ops
A vacuum of 1 inch of Hg is equally to a negative pressure of ______ psi.
3.049 psi

pg 332
pump ops
If you use a test pit, make sure that the usable pit capacity is at least __ gallons for every __ GPM of the pump.
10 gallons for every 1 GPM of the pump

pg 332
pump ops
To ensure accurate and consistent readings, Pitot tubes should be fixed in the center of the stream, with end of the tube located away from the end of the nozzle by a distance that is equal to _____ of the nozzle diameter.
Half of the nozzle diameter

pg 334
pump ops
The first performance test is to check the governed engine speed. If the engine speed is not within +/- __ rpm of the governed speed when the fire apparatus was brand new, this problem must be corrected before proceeding with the additional pump test.
+/- 50 rpm

pg 334
pump ops
Check the alternator tension and the battery charge to ensure that they will provide enough electrical power to allow up to ___ seconds of uninterruped primer operation during the vacuum and priming tests.
45 seconds

pg 334
pump ops
A ____ ____ is a device that allows the bypass of fluids to limit the pressure in a system.
Relief Valve.

pg 335
pump ops
A test of the ____ ____ indicators should be made to verify that they operate in the cab and on the driver/operators's panel indicate correct pump status when the pump is shifted from road mode to pump mode.
Pump shift indicator

pg 335
pump ops
Pressure gauges should be checked at a minumum of three points, including __ psi, ___ psi, and ___ psi. Any gauge that is off by more than __psi must be reclaibrated, repaired, or replaced.
150psi, 200psi, 250psi

any gauge that is off by more than 10psi

pg 338
pump ops
____ ____ need to be checked individually, using a hose stream with a smooth-bore tip and a Pitot tube to measure actual flow.
Flow meters

pg 338
pump ops
Any flow meter whose accuracy is off by more than __% must be recalibrated, repaired, or replaced.
10 %

pg 338
pump ops
When a fire apparatus is new, the pump must be able to develop a vacuum of __ in. Hg, unless the altitude is greater than ____', in which case the vacuum attained is permitted to be less than this by 1" for each 1000'. The vacuum inside the pump or suction hose should not drop in excess of ___ in Hg in ___ minutes.
should develop 22 in. Hg

should not drop in excess of 10 in Hg in 5 minutes

pg 341
pump ops
____ ___ and improperly adjusted ____ ____ are two of the biggest sources of problems on the vacuum test.
Leaking Gaskets and Improperly adjusted Pump Packing

pg 344
pump ops
For pumps that operate at less than 1500 GPM the priming device should be able to create the necessary vacuum in ___ seconds to lift water 10' through 20' of suction hose.
30 seconds

pg 344
pump ops
The priming device on pumps of 1500 GPM or larger should be able to create the necessary vacuum in ___ second to lift water 10' through 20' of suction hose.
45 seconds

pg 344
pump ops
In testing the pump, three variable factors come into play, they are?
1. Pump speed
2. Net Pump Pressure
3. Pump discharge rate

pg 348
pump ops
___ ____ ____ is the sum of the discharge pressure and the suction lift converted to psi or kPa when pumping at draft, or the difference between the discharge pressure and the intake pressure when pumping at a hydrant or other source of water under positive pressure.
Net Pump Pressure

pg 349
pump ops
The pump shold be subjected to a pumping test of at least ___ minutes in duration. Allow the pump, transmission, and engine to warm up for approximately __ minutes prior to beginning the pump tests.
45 minutes in duration

warm up for 10 minutes prior to beginning the pump test

pg 349
pump ops
A complete set of readings should be taken and recorded a minimum of ___ times during the 20-minute test for 100% rated capacity, a minimum of ____ during each 10-minute test for 70% capacity and 50% capacity.
5 times for 100% and 2 times for 70% and 50% capacity

pg 349
pump ops
The pressure control device, a relief valve, or pressure governor located o the pump panel should be tested at ___ psi, ___ psi, ____ psi intervals.
150 psi, 90 psi, and 250 psi

pg 354