GPM Formula

GPM = 29.7 (D)^2 NP



D= Diameter


NP= Nozzle Pressure

FL Formula

FL = CQ^2L



C= Coefficient


Q= GPM÷100


L= Length÷100

Structural Fog/Smooth Bore Hand Line NP

50 psi

Smooth Bore Master Stream NP

80 psi

Master Stream Fog Nozzle

100 psi

Wildland Fog Nozzle

100 psi

1" Coefficient

150

1 1/2" Coefficient

24

1 3/4" Coefficient

10

2 1/2" Coefficient

2

3" Coefficient

.8

4 1/2" Coefficient

0.1

5" Coefficient

0.08

Hand Line GPM



7/8"

160 GPM

Hand Line GPM



15/16"

185 GPM

Hand Line GPM



1"

210 GPM

Hand Line GPM



1 1/8"

250 GPM



(266)

Hand Line GPM



1 1/4"

325 GPM

Master Stream GPM



1 3/8"

500 GPM

Master Stream GPM



1 1/2"

600 GPM

Master Stream GPM



1 3/4"

800 GPM

Master Stream GPM



2"

1000 GPM

Percent Drop Equation

(static - residual)(100)


% drop= -------------------------------


static

3 Like Lines

0-10%



@50 compound >5psi (50-45psi)

2 Like Lines

11-15%



@50 compound 5 > 7.5 psi (45-42.5)

1 Like Line

16-25%



@50 compound 8 > 12.5 psi (42-37.5)

0 Like Lines

</= 26%



@50 compound >/= 37 psi (</= 13)

Pump Discharge Pressure (PDP)

PDP = NP + FL + AL +/- EP



NP= nozzle pressure


FL= friction loss


AL= appliance loss


EP= elevation pressure

PDP for 150' of 1 3/4" with 7/8" @160 GPM


(Pre-connect Crosslays)

PDP = 50 + 38 = 88psi

PDP for 200' of 2 1/2" with 1 1/8" @ 250


(Pre-connects)

PDP = 50 + 2(12.5) = 75psi

FL for 1 3/4" flowing @ 160gpm

25 psi per 100 ft

FL for 2 1/2" flowing 250 gpm

12.5 psi per 100 ft

FL for 2 1/2" flowing 320 GPM



(wyed lines)

20 psi per 100 ft

FL for 2 1/2" flowing 160 gpm



(One wyed line)

5 psi per 100 ft

√100

10

√80

8.94

√75

8.66

√50

7.07

FL for 100' of 1 1/2" flowing 60 GPM



(Wildland Pre-connect)

9 psi



PDP = 100 + 9 = 109

PDP= 200' of 1" Booster Line flowing 40 gpm

PDP = 100 + 48 = 148 (PUMP @ 140)

PDP for 105' Aerial

150 psi + EP to achieve 1000 gpm max

PDP for Deck Gun

PDP = 80 NP + 25 AL = 105 psi

Appliance Friction Loss



Adapters

+ 10 psi if < 350 gpm

Appliance Friction Loss



Appliance

+ 25 psi if < 350 gpm

Supplying Automatic Sprinkler System

PDP @ 150 PSI



+ 10 psi for each additional 100' of hose

Supplying Standpipe System

PDP = NP + FL + 25 AL + EP

Elevation Pressure

EP = 0.5H



or