A standpipe system is a piping arrangement that carries water -




A) From a fixed water tank to a hydrant system.


B) Horizontally through a building for fire fighting operations.


C) Vertically through a building for fire fighting operations.


D) Vertically and sometimes horizontally through a building for fire fighting operations.


Vertically and sometimes horizontally through a building for fire fighting operations.


The first laws that were passed in major cities regarding fire protection, required standpipes in all buildings more than __ high.




A) 50 feet.


B) 75 feet.


C) 100 feet.


D) 125 feet



75 feet.


Which of the following is the Standard for the Installation of Standpipe and Hose Systems?




A) NFPA 14.


B) NFPA 15


C) NFPA 16


D) NFPA 17





NFPA 14.

How many classes of standpipe systems have been designated?




A) 1


B) 2


C) 3


D) 4




3



Which of the following classes of stan pipes systems provide 2 1/2 inch hose connections at designated locations in a building for full-scale fire fighting?




A) Class I


B) Class II


C) Class III


D) All the above.

Class I



Which of the following classes of standpipe systems are intended for first-aid fire fighting operated by building occupants and fire brigades?




A) Class I


B) Class II


C) Class III


D) Class II and Class III




Class II and Class III

Which of the following classes of standpipe systems are intended for first-aid and full scale fire fighting?




A) Class I


B) Class II


C) Class III


D) Class II and Class III



Class III

Which of the following would be considered one of the standpipe system "types" as described in the 1993 edition of NFPA 14?




(1) Automatic wet (2) Automatic dry (3) Semiautomatic dry (4) Manual dry (5) Manual wet.




A) 1, 2, 3.


B) 3, 4, 5.


C) 1, 2, 4, 5.


D) All the above.

all of the above


Which of the following standpipe system types, has piping that is filled with air, has no preconnected water supply, and utilizes a fire department connection to maintain a water supply for fire fighting?




A) Automatic Dry.


B) Semiautomatic Dry.


C) Manual Dry.


D) Manual Wet

Manual Dry.

Which of the following standpipe system types, has piping that is filled with pressurized air, and will admit water automatically into the system when a hose valve is opened?




A) Automatic Dry.


B) Semiautomatic Dry.


C) Manual Dry.


D) Automatic Wet.

Automatic Dry.

Which of the following standpipe system types, is filled with air that may or may not be pressurized?




A) Automatic Dry.


B) Semiautomatic Dry.


C) Manual Wet.


D) Automatic Wet.

Semiautomatic Dry.

Which of the following standpipe system types, has piping that is filled with water at all times and is capable of supplying the water demand for fire fighting?




A) Automatic Dry.


B) Semiautomatic Dry.


C) Manual Wet.


D) Automatic Wet.

Automatic Wet.

Which of the following standpipe system types, has piping that is filled with water for the purpose of allowing leaks to be detected, but is not capable of supplying fire fighting water demands?




A) Automatic Dry.


B) Semiautomatic Dry.


C) Manual Wet.


D) Automatic Wet.



Manual Wet.

Which type of standpipe system does not have a reconnected water supply for firefighters, and must be supplied by connecting hoses from the pumper to the FDC?




A) Manual.


B) Automatic.


C) Semiautomatic.


D) Omniautomatic.




Manual.



Which of the following statements is true?




A) Only fire department pumpers feed dry standpipe systems.


B) Dry standpipe systems will normally have interior 1 1/4 inch hoselines available to residents.


C) Dry standpipe systems will normally have interior 1 3/4 inch hoselines available to residents.


D) Dry standpipe systems are never found in unheated buildings.



Only fire department pumpers feed dry standpipe systems.




Newer fire codes regarding multiple-riser dry systems require -




A) Each FDC must be clearly marked as to which parts of the building water will be fed to.


B) Each FDC must be color-coded to indicate which part of the building water will be fed to.


C) Each FDC location must show a map, of all risers installed in the building and which sections of the building each riser feeds.


D) All multiple-riser dry systems must be interconnected so water is pumped to intake feeds in all risers.



All multiple-riser dry systems must be interconnected so water is pumped to intake feeds in all risers.

All automatic wet standpipe systems -




A) Must be connected to a fire department pumper in order to be effective.


B) Are connected to a water source and contain water at all times.


C) Are connected to a water source, but require a fire department pumper to create enough pressure to allow and effective fire attack.


D) Can not maintain the residual pressure requirements to allow for an effective fire attack.





Are connected to a water source and contain water at all times.

NFPA 14 requires that a water supply for Class I and Class III systems be able to deliver a residual pressure of __ at the outlet of the top-most connection at each standpipe.




A) 100 psi.


B) 120 psi.


C) 135 psi.


D) 150 psi.



100 psi.

What is the required flow from each of the two top-most hose connections of the hydraulically most remote standpipe, plus from each additional standpipe up to the required maximum?




A) 150 gpm.


B) 200 gpm.


C) 250 gpm.


D) 300 gpm.

250 gpm.

NFPA 14 requires that a water supply for a Class II system be capable of delivering 100 gpm.for -




A) 5 minutes.


B) 15 minutes.


C) 30 minutes.


D) At least 1 hour.

30 minutes.

Under NFPA 14, a Class II system must be strong enough to maintain a residual pressure of __ at the outlet for the hydraulically most remote hose connection at a flow rate of 100 gpm.




A) 50 psi.


B) 65 psi.


C) 75 psi.


D) 100 psi.

65 psi.

Under the 1993 edition of NFPA 14, what is the minimum outlet pressure for Class I and Class III outlets?




A) 50 psi.


B) 65 psi.


C) 75 psi.


D) 100 psi.



100 psi.



Automatic and semiautomatic standpipe systems require a minimum of __ preconnected water supply that is capable of supplying the standpipe system's hydraulic demand for a minimum duration.




A) 1


B) 2


C) 3


D) 4

1

For high-rise buildings, how many remotely located FDCs are required for each zone within the pumping range of the fire apparatus in addition to the automatic water supply?




A) 1


B) 2


C) 3


D) 4

2

The most often used water supply sources in wet standpipe systems would include all but which of the following?




A) Waterworks systems.


B) Gravity tanks and pressure tanks.


C) Fire pumps.


D) Rivers, ponds, and streams.

Rivers, ponds, and streams.



When two or more water sources feed a wet standpipe system -




A) The system providing the highest pressure will be the one that provides the water.


B) The system providing the lowest pressure will initiate feeding the system, and then be supplemented by one or more additional supplies.


C) All water sources will provide equal volume in order to maximize and raise the pressure in the standpipe system.


D) The system will constantly alternate its water supply in order to ensure a constant and uninterrupted flow of water.






The system providing the highest pressure will be the one that provides the water.



When available, which of the following water supplies are almost always used as the primary source of water in wet standpipe systems?




A) Fire pumps.


B) Public waterworks.


C) Gravity tanks.


D) Pressure tanks.

Public waterworks.

Gravity tanks may hold as much as __ gallons of water.




A) 25,000 gallons.


B) 50,000 gallons.


C) 75,000 gallons.


D) 100,000 gallons

100,000 gallons.

Gravity tank systems that supply one and two-story buildings are normally mounted -




A) In the basement of the building.


B) On the roof of the building.


C) On the ground.


D) All the above




On the ground.

Which of the following water supply sources are found only on smaller systems where they supply hoselines for initial attack by the occupants.




A) Pressure tanks.


B) Gravity tanks.


C) Public waterworks.


D) Fire pumps.

Pressure tanks.



Pressure tanks rarely exceed __ in capacity when supplying water to wet standpipe systems.




A) 1000 gallons.


B) 3000 gallons.


C) 5000 gallons.


D) 10, 000 gallons.




3000 gallons.



A pressure tank differs from a gravity tank in that -




A) Pressure tanks contain more water.


B) Pressure tanks contain less water.


C) Gravity tanks must be mounted on the roof of a building, while pressure tanks can be mounted anywhere.


D) The top third of a pressure tank contains air under pressure.

The top third of a pressure tank contains air under pressure.

Which of the following statements is true?




A) Water tanks when empty become useless as a water supply.


B) Pumpers should always be used to supply any standpipe system either wet or dry.


C) Wet systems may contain two or more risers.


D) All the above.

All the above.

In multi wet systems -




A) All risers are supplied by the same source or sources.


B) Each riser is supplied by separate water sources.


C) One riser is supplied by a static water source, and other risers are supplied through the FDC.


D) One riser is supplied by a residual water source, and all other risers are supplied by a static water source.


All risers are supplied by the same source or sources.

When risers are interconnected, the system must have -




A) One or more intakes.


B) Two or more intakes.


C) Three or more intakes.


D) At least one intake at every corner of the building.




Two or more intakes.

Which type of valve is usually found on industrial and warehouse properties?




A) Ball valves.


B) Outside stem-and-yoke valves.


C) Post indicator valves.


D) Gate valves.

Post indicator valves.

Gate valves, or outside stem-and-yoke valves are normally installed on all but which of the following?




A) Office buildings.


B) Apartment buildings


C) Stores.


D) Factories.



Factories.

Before attempting to use a standpipe, firefighters should -




A) Check to make sure that the postindicator valves are in the "Open" position.


B) Check to make sure that the postindicator valves are in the "Closed" position.


C) Make sure that the engine is properly connected to the FDC.


D) Check to make sure that the gate valves are closed.



Check to make sure that the postindicator valves are in the "Open" position.

FDCs are required for which of the following standpipe systems?




(1) Class I (2) Class II (3) Class III




A) 1, 3.


B) 2, 3.


C) 1, 2.


D) All the above.

1, 3.

As a rule, most FDCs are provided with one 2 1/2 inch inlet for each __ of design flow.




A) 100 gpm.


B) 150 gpm.


C) 200 gpm.


D) 250 gpm.

250 gpm.



It is preferable to use __ or larger piping for connecting the FDC to the system mains.




A) 2 1/2 inch.


B) 3 inch.


C) 4 inch.


D) 5 inch.

4 inch.

The first step in hooking up to a FDC is to -




A) Hook the first line up to the left intake.


B) Hook up the first line to the right intake.


C) Ensure that the clapper valves are closed.


D) Check the FDC for garbage and debris

Check the FDC for garbage and debris.


You arrive at a building fire and are ordered to hook up to the FDC. You quickly realize that the FDC siamese has been damaged, and it will be impossible for you to make the connection. What do you do?




A) Call immediately for mutual aid.


B) Prepare to stretch large diameter hose to the front door, and connected a gated wye.


C) Supply the system through the hoseline outlet on the first floor.


D) Look for another job.

Supply the system through the hoseline outlet on the first floor.

If it is necessary to use the first floor hoseline outlet to supply water to a building, the houseline and pressure reducing fittings should be removed and replaced with a -




A) 2 1/2 inch siamese with a double female adaptor.


B) 2 1/2 inch siamese with a double male adaptor.


C) Single supply line from the pumper.


D) 2 1/2 inch gated wye with all the proper fittings.

2 1/2 inch siamese with a double female adaptor.

The best arrangement for supplying a standpipe system is to position the pumper within __ of the standpipe siamese.




A) 50 feet.


B) 100 feet.


C) 150 feet.


D) No more than 200 feet.



100 feet.

Firefighters arrive at a building where the fire is located on the 5th floor. What should firefighters do as they proceed to the fire floor to hook into the standpipe system?




A) Check the elevators to make sure they are functional.


B) Check to see if they are carrying all the necessary equipment to make the connection and fight the fire.


C) Take the stairs and check to ensure that all hose outlet valves are closed on the lower floors.


D) All the above.

Take the stairs and check to ensure that all hose outlet valves are closed on the lower floors.

Which of the following statements is not true?




A) Fire departments should have all the necessary tools and equipment and a way to transport them quickly and effectively to the fire floor.


B) Hose and all equipment should be lightweight.


C) Only equipment absolutely necessary should be carried into the building, especially on the initial attack.


D) Whenever possible, firefighters should utilize houselines, thus allowing a quicker fire attack.

Whenever possible, firefighters should utilize houselines, thus allowing a quicker fire attack.



The first hoseline in a building should be at lease __ and of a diameter that is appropriate for the size and intensity of the fire.




A) 100 feet.


B) 150 feet.


C) 200 feet.


D) 250 feet

150 feet.

Which of the following hose configurations would you expect in a "standpipe pack?"




A) Flaked.


B) Prerolled.


C) Donut-rolled.


D) All the above

All the above.

You would expect all the following equipment to be included in a standpipe pack except for -




A) 150 feet of 1 3/4 inch hose.


B) Solid-bore nozzle, and handwheel or small pipe wrench.


C) Spanners and adapters.


D) Bolt cutters and K tool.

Bolt cutters and K tool.

Which size hoseline is considered effective on most fires in the typical building containing a standpipe system?




A) 1 inch lightweight forestry hose.


B) 1 1/2 inch hose.


C) 1 3/4 inch hose.


D) 2 1/2 inch hose.

1 3/4 inch hose.

Besides a standpipe pack, firefighters should carry all but which of the following equipment into the building?




A) Smoke ejectors, and positive pressure fans.


B) Forcible entry tools.


C) Portable lighting.


D) Attic ladders.



Attic ladders.

All equipment necessary to support the fire fighting operation should be brought to a designated area called the -




A) Interior staging area.


B) Resource area.


C) Equipment pool.


D) All the above.



All the above.

The equipment pool should be located -




A) On the ground floor.


B) On the fire floor.


C) Two or more floors below the fire.


D) Two or more floors above the fire.

Two or more floors below the fire.

When working in the fire building, specific assignments must be given to -




A) A single firefighter to create a more efficient attack.


B) At least two firefighters.


C) At least three firefighters.


D) Interior attack crews should stay together and never be broken down into individual assignments.



At least two firefighters.

) A personnel accountability system should be in place -




A) When there is smoke showing from a structure.


B) When there is fire showing from a structure.


C) Whenever the incident commander deems it necessary.


D) At every incident.



At every incident.

Which of the following best describes lapping?




A) When fire spreads rapidly in a horizontal direction, such as down hallways and through large open rooms.


B) When fire spreads rapidly vertically, such as through open stairwells and elevator shafts.


C) When fire spreads rapidly through the convection of steel beams and plumbing.


D) When fire jumps from floor to floor through exterior windows.

When fire jumps from floor to floor through exterior windows.

Besides search and rescue and fire extension, what should be a priority for engine company firefighters working on floors below the fire during the initial attack?




A) Property conservation.


B) Ventilation.


C) Rehabilitation.


D) Overhaul.

Property conservation.

The use of elevators in a high rise fire is a risk versus benefit decision of the incident commander. Under what circumstances should firefighters always avoid the use of elevators?




A) When the elevator will stop on the floor just above the fire.


B) When the elevator will stop on the fire floor.


C) When the fire is on the lower floors of a building.


D) All the above.

All the above.

If an elevator is to be used to gain access to the fire, where should it stop?




A) On the floor two floors or more above the fire, and then walk down using the stairs to the fire floor.


B) On the floor two floors or more below the fire, and then walk up using the stairs to the fire floor.


C) The elevator may stop at any floor if the elevator shaft is on the exterior of the building and the firefighters have a clear and unobstructed view of the entire building.


D) Because of the possibility of power failure the elevator should never be used.



On the floor two floors or more below the fire, and then walk up using the stairs to the fire floor.

What does a fire service control in each car and in the lobby do for firefighters working at a high rise fire?




A) Allows them to control the car, even if the power is disconnected from the building.


B) Allows them to open the door of the car in case power is cut to the car.


C) It cuts off the response to call buttons on each floor.


D) It allows the firefighters to control the speed of in which the car travels.

It cuts off the response to call buttons on each floor.

In a high-rise building, which standpipe connection should firefighters hook into when executing their initial fire attack?




A) The standpipe on the fire floor.


B) The standpipe just above the fire floor.


C) The standpipe just below the fire floor.


D) The standpipe on the ground floor.

The standpipe just below the fire floor.

There is a fire in a high rise building. The fire has gained a substantial amount of headway causing intense heat that prevents firefighters from mounting a direct attack. The fire floor is beyond the reach of aerial apparatus. Which of the following would be a realistic option?




A) Consider a helicopter water drop.


B) Position unmanned master streams as close to the fire floor as possible.


C) Withdraw from the building and attempt to protect exposures.


D) Enter a near by building and connect to its standpipe system and fight the fire from the roof or windows of the nearby building.



Enter a near by building and connect to its standpipe system and fight the fire from the roof or windows of the nearby building.



Firefighter Pete says that if a high-rise fire is beyond the reach of aerial apparatus and an exposure problem exists, all fire apparatus should be committed to the fire building standpipe system.


Firefighter Patty says that if a high-rise fire is beyond the reach of aerial apparatus and an exposure problem exists, fire apparatus should be committed to the fire building standpipe system, as well as the standpipe systems of the exposures.


Who is correct?




A) Firefighter Pete.


B) Firefighter Patty.


C) Both are correct.


D) Neither are correct

Firefighter Patty.

Firefighter Sam says that a properly installed, maintained and supported automatic sprinkler system can apply water directly to a fire in a more effective manner than can the fire department using manual fire-suppression methods.


Firefighter Ted says that although automatic sprinkler systems can be effective in fire-suppression, there is no substitute for the amount of pressure, and volume that can be delivered to a fire using conventional fire fighting techniques.


Who is correct?




A) Firefighter Sam


B) Firefighter Ted.


C) Both are correct.


D) Neither are correct

Firefighter Sam

Automatic sprinkler heads are capable of distributing water over an area of -




A) 50 square feet.


B) 100 square feet.


C) 125 square feet.


D) 145 square feet.



100 square feet.

Which of the following constitutes the four basic types of sprinkler systems?




(1) Wet-pipe (2) Dry-pipe (3) Reaction (4) Preaction (5) Heat-sensitive (6) Deluge




A) 1, 2, 4, 6.


B) 1, 2, 3, 5.


C) 1, 2, 5, 6.


D) 1, 2, 3, 5.

1, 2, 4, 6.

Which of the following sprinkler systems have piping that is completely filled with water from the source to the heads?




A) Wet-pipe system.


B) Preaction system.


C) Deluge system.


D) A and B.




Wet-pipe system.

Which of the following is the simplest and one of the least expensive sprinkler systems, that requires little in the way of special equipment?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system.

Wet-pipe system.

Which of the following sprinkler systems is usually installed in high-hazard locations such as aircraft hangers, chemical plants, laboratories, and transformer rooms?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system.

Deluge system.

Which of the following sprinkler systems is devised to minimize the time the sprinkler system is delivering water, by exhausting the compressed air from the pipes before the sprinkler heads open?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system.

Preaction system.


Which of the following sprinkler systems acts on a pressure differential principle, in which the surface area of the valve face on the air side is greater than the surface area on the water side?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system.

Dry-pipe system.

Which of the following sprinkler systems is designed to deliver large volumes of water quickly?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system.

Deluge system.

Which of the following is the Recommended Practice for Fire Department Operations in Properties by Sprinkler and Standpipe Systems?




A) NFPA 12A


B) NFPA 13E


C) NFPA 14C


D) NFPA 15D

NFPA 13E

Which of the following sprinkler systems has piping from the valve to the heads that contain only room air, with the sprinkler heads in an open state at all times?




A) Wet-pipe system.


B) Dry-pipe system.


C) Preaction system.


D) Deluge system

Deluge system.



Which of the following statements is not true?




A) Upon arriving at a property protected by automatic sprinkler systems, fire companies should take immediate action to supply the sprinkler system.


B) Every sprinkler system must be equipped with a fire department intake.


C) During an incident, a firefighter must be assigned to the main valve and fire pump to ensure a continued operation of the system.


D) Once hooked into the system, the pump operator should immediately begin pumping the system.



Once hooked into the system, the pump operator should immediately begin pumping the system.

Books and publications on supplying sprinkler systems recommends a pumping pressure of __, but department SOGs and preplans could modify this figure.




A) 100 psi.


B) 125 psi.


C) 150 psi.


D) 175 psi

150 psi.



You arrive at a building fire with an automatic sprinkler system. You immediately attach your supply lines to the sprinkler siamese connection. What should you do next?




A) Firefighters should prepare for an offensive attack.


B) Firefighters should prepare for a defensive attack.


C) Firefighters should prepare for a combination attack.


D) Firefighters should remain outside of the building and maintain water to the system, and protect exposures.



Firefighters should prepare for an offensive attack.

The one deterrent to effective sprinkler system operation other than human error is -




A) The presence of older equipment used in the system.


B) A shortage of fire fighting personnel at the scene.


C) An inadequate water supply.


D) All the above.

An inadequate water supply.

Firefighter Alex says that the sprinkler systems of exposed buildings should be supplied with water from pumpers.


Firefighter Alice says that all water from pumpers should be reserved for supplying water to the fire building only.


Firefighter Aaron says that pumpers should be used to supply sprinkler systems with water, not to rob them of their water.


Who is correct?




A) Firefighters Alex and Aaron.


B) Firefighters Alice and Aaron.


C) Firefighters Alex and Alice.


D) They are all correct.

Firefighters Alex and Aaron.

Which of the following is a common mistake made when automatic sprinkler systems are in operation?




A) Not assigning a firefighter to the main valve and fire pump.


B) Pumping water into the system from a pumper before being ordered to do so by the incident commander.


C) Shutting down the system prematurely.


D) Not maintaining an adequate water supply to exposures.



Shutting down the system prematurely.

Why would firefighters shutdown a sprinkler system before they are sure whether or not the fire has been extinguished?




A) To conserve water.


B) To redirect water to handlines and master streams.


C) To redirect water to protect exposures and high-value properties.


D) To decrease water damage.

To decrease water damage.

Which of the following statements is true in regard to fire department action once the fire has been extinguished?




A) Even after the fire has been extinguished, the firefighter assigned to the valve should stay in position in case the fire starts up again.


B) Property conservation methods should be started to ensure the least amount of damage to the building.


C) The incident commander should contact the building owner or management company.


D) All the above.

All the above.



Firefighter Lee says that if after a fire, the sprinkler system can not be put back into service, the premises should be guarded by building security.


Firefighter Liza says that if after a fire, the sprinkler system can not be put back into service, the premises should be guarded by an assigned fire detail.


Who is correct?




A) Firefighter Lee.


B) Firefighter Liza.


C) Both are correct.


D) Neither are correct. The police department should be used to guard the premises.

Both are correct.

What are examples of built-in fire protection systems.
Stand-pipe systems and sprinkler systems are both built-in fire protection systems.
standpipe systems are usually installed in large structures such as high-rise apartments and office buildings and warehouses to eliminate ________________________
Usually installed in large structures such as high-rise apartments and office buildings and warehouses to eliminate the need for long stretches of hose lines from the street to the fire floor.
What is a standpipe system?
A piping arrangement that carries water vertically and sometimes horizontally through a building for firefighting operations.
what is the purpose of a standpipe system?
The purpose is to provide a means of getting water to a fire without long, time-consuming, hose stretches.

The first laws passed required standpipes in all buildings more than_______' high.




however, many buildings more than _______ stories, but less than 75' still did not have standpipes

. The first laws passed required standpipes in all buildings more than 75’ high.




3 stories


What is the NFPA Standard for Installation of Standpipe and Hose Systems?
NFPA 14
how many classes of standpipe systems are there?


3



Class 1 Standpipe System

Provide 2-1/2” hose connections at designated locations in the building for full-scale firefighting.




* These systems are generally intended for use by the fire department rather than building occupants

Class 2 Standpipe System

Provide 1-1/2” hose connections at designated locations in the building for first-aid firefighting.




* Intended for use by building occupants before the fire department arrives.




* This system is usually supplied with hose, a hose rack, and cabinet and a nozzle installed at each hose connection

Class 3 Standpipe System

A combination of Class I and Class II




* Can be used for full-scale and first-aid firefighting.




* Class I and Class II hose connections are provided with this system.

Automatic Wet Systems
Piping that is filled with water at all times and have an automatically available supply capable of supplying water demand necessary for firefighting.
Automatic Dry Systems

Piping is normally filled with pressurized air




*Connected to an automatically available water supply that is capable of supplying the water demand necessary for firefighting

Semi-automatic Dry Systems




1. Piping is normally filled with air that may or may not be pressurized.




2. These systems utilize a deluge valve that admits water into the system piping when a remote actuation device located at a hose station, such as a pull station, is operated




.3. They also have a pre-connected water supply.

Manual Dry Systems


*Piping is normally filled with air




* Do not have a pre-connected water supply.




*A FDC must be used to maintain water supply for firefighting.

Manual Wet

*Piping that is normally filled with water for the purpose of allowing leaks to be detected.




*Water supply is typically provided by a small connection to domestic water piping and it is not capable of meeting firefighting demands.




* A FDC must be used to supply water manually for firefighting.

Dry Systems




are they equipped with interior lines for occupant use?

A dry standpipe is a vertical pipe, or riser, running through or along the outside of the building. They are not equipped with interior lines for occupant use; only fire department pumpers can feed them.

Dry Systems




Where are the outlets and inlets located within the structure?

There is one outlet at each landing, with the inlet placed at the bottom of the pipe, a few feet above the ground.

Dry Systems




Dry Systems may be found in what kind of buildings?

Dry systems may be found in unheated buildings, in buildings in cities that do not require wet systems, and in buildings built before retroactive standpipe laws were passed.

Wet Systems



Connected to a water source and contains water at all times

wet system




what kind of pressure is on the system

Must contain enough pressure to allow fire attack without support from fire department pumpers

wet Systems



Required by NFPA 14 to be able to deliver a residual pressure of __________ psi at the outlet of the top-most hose connection on each standpipe for Class I and Class II systems.

Required by NFPA 14 to be able to deliver a residual pressure of 100 psi at the outlet of the top-most hose connection on each standpipe for Class I and Class II systems.




**This pressure must be available while flowing 250gpm from each of the topmost hose connections of the hydraulically most remote standpipe, plus 250gpm from each additional standpipe, up to the required maximum.

wet systems


NFPA 14 also requires that a water supply for a Class II system be capable of delivering ______gpm for ______ minutes.

NFPA 14 also requires that a water supply for a Class II system be capable of delivering 100gpm for 30 minutes.
The minimum outlet pressure for Class I and Class II outlets is now ______ psi after a modification to NFPA 14 in 1993 changing it from the 65 psi.
The minimum outlet pressure for Class I and Class II outlets is now 100psi after a modification to NFPA 14 in 1993 changing it from the 65 psi.
When two or more sources feed a wet standpipe system, Which source will the standpipe system use to provide the water?
When two or more sources feed a wet standpipe system, the source providing the highest pressure will be the one that provides the water.
A ____________keeps possible contaminated water from entering the potable water system.
A check-valve keeps possible contaminated water from entering the potable water system.
*When available, a_________________almost always is used as the primary water source.
*When available, a public waterworks system almost always is used as the primary water source.
Gravity systems
They are mounted on the ground when supplying one and two story buildings or mounted above ground on taller structures. They may hold as much as 100,000 gallons of water.

how do Pressure tanks differ from gravity tanks?


where are they usually found?

Pressure tanks differ from gravity tanks because the top 1/3 of the tank contains air under pressure.




These are generally found only on smaller systems and supply house lines with water for initial attack by the occupants.

. FDCs are required on all Class___ and Class___ systems.
. FDCs are required on all Class I and Class III systems.

As a rule, most FDCs are provided with a


________ inlet for each _______gpm of design flow rate.

As a rule, most FDCs are provided with one 2-1/2” inlet for each 250gpm of design flow rate.
**If the fire is severe, a fire department __________________ can be placed on a standpipe connection intake and additional supply lines can be hooked into the system.
**If the fire is severe, a fire department siamese appliance can be placed on a standpipe connection intake and additional supply lines can be hooked into the system.
The best arrangement for supplying a standpipe system is to have a pumper positioned within _________ feet of the standpipe siamese.
The best arrangement for supplying a standpipe system is to have a pumper positioned within 100feet of the standpipe siamese.
When utilizing standpipes, the first hose line in the building should be at least ________ feet long and of a diameter dictated by the size and intensity of the fire.
When utilizing standpipes, the first hose line in the building should be at least 150 feet long and of a diameter dictated by the size and intensity of the fire.
An equipment staging area, or “equipment pool” should be set up usually _________ floors below the fire, depending on conditions on the fire floor or other ongoing activities within the building.
An equipment staging area, or “equipment pool” should be set up usually two or more floors below the fire, depending on conditions on the fire floor or other ongoing activities within the building.

Fire tends to extend vertically because of




LAPPING. what is that?




What Types of buildings is this especially true for? and why?

Fire tends to extend vertically because of lapping, or leap-frogging from window to window. Lapping refers to fire that jumps from floor to floor through exterior windows. This is especially true in fire-resistive buildings because heat is typically forced to the exterior windows which is the weakest part of the building
is it ok to use elevators on the lower floors?
Elevators should not be used for fires on lower floors. Stairways should be used to gain entry to these type fires.
is it ok to take a quick glimpse of the fire floor from the elevator?

no nonononononononono
if using the elevator, which floor should you get off ?
Fire fighters should stop TWO floors or more below the fire and then use the stairway to the fire floor.

If the fire is located some distance down the corridor from the stairway, the initial hookup can be made on the fire floor!




is this true? what precautions would have to be made?

If the fire is located some distance down the corridor from the stairway, the initial hookup can be made on the fire floor; however, this should not be attempted unless the firefighters are certain the fire is confined to an area off the corridor or at least some distance from their point of entry to the fire floor.

The most common type of sprinkler system?




tell me a little about it

The most common type of sprinkler system is the wet-pipe system




the piping is always filled completely with water from the source to the heads

sprinkler systems


Dry-Pipe System

Dry-Pipe System . The system contains water only from the source to a control valve, known as the dry-pipe valve

Pre-Action System


-What is it?


-is it dry or wet?


-What is it controlled by?



Devised to minimize the activation time by exhausting the compressed air before the head opens.




2. This is a dry system with the addition of air exhausters




3. This is controlled by a supplemental fire detection system.




4. Pre-Action systems can be used wherever dry pipe systems can be used.

Deluge System


-What is it?


-Control of the system is where?


-What types of buildings usually have them?

Contains only water from the source to a control valve. The piping from the valve to the heads contains only room air, and the heads are open at all times.




2. Complete control of the system is provided at the valve.




3. Deluge systems usually are installed in high-hazard locations such as aircraft hangers,chemical plants, laboratories, and transformer rooms, or other areas where fire might spread rapidly.

**During an actual fire incident, a fire fighter must be assigned to the ________ and _________to ensure a continued operation of the system.**
**During an actual fire incident, a fire fighter must be assigned to the main valve and fire pump to ensure a continued operation of the system.**
What is the NFPA Standard Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems
*NFPA 13E, Recommended Practice for Fire Department Operations in Properties Protected by Sprinkler and Standpipe Systems**
A pumping pressure of ___________ psi is recommended for sprinkler systems.
A pumping pressure of 150psi is recommended for sprinkler systems.