  • Front
  • Back
RECEO
Rescue
Exposure protection
Containment
Extinguishment
Overhaul and Salvage
Guidelines for ordering greater alarms:
1. Life Hazards
2. Fire involving more than one floor of a building
3. Heavy Smoke or fire showing from a building of appreciable size
4. Personnel Level
5. Access to fire area
1st Alarm response:
2 engines
1 truck
1 BC
Full 1st Alarm:
1st alarm PLUS:
1 engine
1 truck or USAR
1 BC
Med 30
2nd Alarm
A full first PLUS
2 engines
1 truck or USAR
1 BC
DSO, AIR 6, HIT 29, duty investigator
PG and E
3rd Alarm Response:
A second alarm response PLUS:
2 engines
1 truck or USAR
DUTY MECHANIC, IDT, FIRE ASSOC, NOTIFY WATER CO., CITY MANAGER, DISPATCH BC TO COMUNICATIONS
4TH Alarm Response:
A 3rd Alarm PLUS
2 engines
1 Truck or USAR
1 BC
When do 40 hr., uniformed personnel respond to BET w/ turnouts during normal working hours?
4th Alarm
5th Alarm
A 4th PLUS:
2 engines
1 truck or USAR
SJFD uses what method of search?
searcher/orientator method
What is the best size for a search team?
2 - 4 FF
What are search keys?
to show that a room has been searched
When searching, which side of hand do we use?
sweep with the back of hand, so we don't accidently grab a "hot" wire.
Vertical ventilation
Opening a hole above the fire to let out trapped smoke and heated gases.
Positive Pressure ventilation
to force air into a building thereby pressurizing the building through smaller openings.
During PPV, how do we get more air into building?
set blowers in series, or parallel
Horizontal Ventilation
using wind as an aid, we get smoke and gases out of a building.
What does AWARE stand for?
the RIC team uses AWARE for accountability of tools that are used by RIC:
Air bottle with regulator
Water, dedicate a charged hoseline to protect trapped FF or FF over taken by fire
Define Strategy?
involves the development of a plan for the deployment of resources to most effectively combat the situation
Define tactics?
are the actual methods of operation employed by individual or group of companies to achieve the strategic goals identified by the IC
When do you restore the fire protection system at a fire?
During overhaul, restore the system of possible, or notify the authorities assigned to accomplish the restoration.
How long is our cool down period?
20 minutes
Body retrieval is not_________?
Rescue
When attacking a basement fire, what needs to happen beforehand
ventilation
If you flow a stang, when do you need a water supply?
You need a dedicated water supply before you flow the stang.
Half Strip?
HAM

Hose Pack
Axe or forcible entry tools
Masks and SCBA with PDL
Full Strip on Engine Co.
HAM ROLLS

Hose packs
Axe forcible entry tool
Masks and SCBA W/ PDL
Rope or utility line
Oxygen or resuscitator
Ladders
Lifeline........
Truck Strip:
PASS

Pikepoll
Axes or forcible tools
salvage covers
Spare SCBA bottles per person
When working from ladder,
Have a leg lock or a life belt that is secure
How often do we inspect life belts?
monthly
What kind of communication must be maintained when working inside of a fire with another member?
visual contact, voice contact. radios shall not be substituted in this instance.
What are the roles of the TWO OUT members?
-one assigned to monitor and track interior personnel
- one shall serve as a secondary support member
Can IC upgrade the "Two Out" team to a full RIC team?
Yes
When can there be an exception to the "two out" rule?
When there is immediate life danger and rescue imminent and necessary.
When is the search rope pack put into service at a call?
on a single family residence of 3000 sq ft or greater including offices, commercial structures, warehouses
How many members in a large area search team?
5
What is a public exclusion zone?
Areas marked by yellow/black barrier tape or other means where the public are not allowed to enter.
Define Life Hazard
The existence of a process or condition that would likely cause serious injury or even death.
Define life hazard zones
A qualified person in a location where they can safely observe a hazard. They can deny entry if needed
What color is the tape that marks a LIFE HAZARD identification?
Red and white barrier tape
How many PPM does CO have to be an IDLH?
35 PPM
When an officer sets up staging, how does he set up his apparatus to show where staging is?
Assume a position that is visible and accessible to incoming companies and place two orange cones on the apparatus.
What are the main duties of a staging officer?
-maintain a record of companies
-report resources to the IC by companies
-stock pile tools and equipment
-ensure that apparatus are parked properly
Which company takes over as staging officer
First company arriving in staging, unless otherwise directed by IC
HIT will be dispatched on 2nd alarms code 3 for what reason?
to assist the IC with setting up the command post. HIT CA will assume the plans section chief function and the crew will fill the situation unit and resource unit.
Where will the initial Command Post be set up?
At the rear of the first arriving BC vehicle.
Under what conditions do we need an Incident Action Plan?
If the incident is expected to last more than 12 hours, involve mutual aid, or is rapidly escalating, begin an IAP
rose colored T cards?
each single engine company
Tan colored T cards?
misc. equipment/task force, two piece companies such as truck company, wildland engines, engine tenders. Also for support equipment such as HIT or Air 6
White color T cards?
for members not assigned a primary resource such as an engine or truck company. Usually, chief officers, training officers, inspectors or admin.
Grey T cards?
carried on all BAT vehicles for the purpose of organizing the nylon T-card sorter
When is wildland season?
May through October
Can Captain of 2 piece company split the company?
Yes, Up to the Captain.
What to do when responding to a serious work related injury?
Notify OSHA within 24 hours
Auto aid to central fire, what radio channel do we respond on?
Blue
what radio channel do we use to communicate with other jurisdictions during mutual aid?
White, with exception of assisting central fire
Frequency for SJFD?
154.010
What is order of doing call backs?
BC, CA, ENG, FF
Who determines the number of personnel called back for assignment to the emergency?
IC
What makes up a wildland engine company?
engine and brush patrol
What makes up a brush patrol group?
2 brush patrols staffed by:
1 CA
2 FE
2 FF
what is the dispatch order for brush patrols in SJFD?
1ST, BP group #1 on a TIER 2
2ND, BP group #5 on a TIER 3
3RD, BP group #3 on a TIER 4
Low burn index level?
0 - 30
Moderate burn index level
31 -50
High burn index level
51 -70
Very High index level
71 - 90
Extreme burn index level
91 - 100
TIER 1 RESPONSE:
2 WILDLAND ENGINES
1 ENGINE
2 BC
TIER 2 RESPONSE:
A TIER 1 response PLUS:
2 Wildland engine company
1 engine tender company
1 BP Group
1 BC
MED 30
Duty Chief
Safety Officer
Wildland Officer
TIER 3 RESPONSE:
A TIER 1 and 2 response, PLUS:
1 Wildland Engine Company
1 Engine Tender Company
1 Brush Patrol Group
(2BP'S, 1 CA, 2 FEs, 2FF)
TIER 4 RESPONSE:
TIER 1,2, and 3 PLUS:
1 Engine
1 Brush Patrol Group
1 Engine Tender Company
TIER 5 RESPONSE:
TIER 1,2,3, and 4, PLUS:
MUTUAL AID RESPONSE
When responding to TIER fires, all units respond on which radio channel?
SJFD Channel to stagging unless otherwise directed.
When assistance with a vegetation fire exists what single option does the IC have for assistances?
Calling for a TIER response. Do not piece meal.
Ratio for D-40 to water is?
8 oz. of D-40 to 125 gallons of water

Found at Company stores
How much water does our portable folding tanks hold?
1000 gallons when filled to a depthof 25 inches and 1100 gallons when filled to the maximum.
Floto Pump concerns:
-Don't let it sink

-max pressure is 108psi@10GPM
When do we don our fire shelters?
Anytime we leave the apparatus at a wildland fire which more than one piece of equipment has been dispatched
How big is the fire shelter and construction?
6x4x2

- fiberglass layer sandwiched between a fire resistant paper interior and a thick aluminum exterior
Light fuels in SAn Jose will not exceed _____degrees when burned?
500
Fire shelter temperature have been exposed to _____degrees for periods of 15 minutes with interior temps not exceeding______degrees.
700 degrees outside
105 degrees inside
Removing a Fire Shelter from service due to tears of how big?
1 inch
Remove from service if if has dents or punctures over _______.
1 inch wide

1/2 inch of foil is missing
Important safety concerns with whiff masks?
Never try to moisten your whiff mask insert with water, results will be steam burns.
What is a Ground (Electrical Terminology)?
An electrical connection to the earth or a large body of zero potential.
FF Operations can be normal if, how far from electrical transmission lines.
100 feet
How can heavy smoke plumes affect electrical lines?
It may cause a ground short
What is the minimum distance to any transmission structure that should be observed?
35 foot minimum distance to any transmission structure that should be observed.
When near a high voltage line never:
direct hose stream:
-at or above wires
-in the heavy plume of smoke within 100 feet
-at burning trees under lines
At Station 20, what is minimum staffing from 0600 - 2400? Also from 2400 - 0600?
6 and 4
How many gallons of AFFF,water and halon does Engine 20C have
205 gallons AFFF
1585 gallons water
500lbs Halon 1211
How many gallons AFFF, water, and halon on E20A and E20B?
180 gallons AFFF
1500 gallons water
150 lbs halon1211
Define light aircraft?
6 passengers of less
Airport Alert 1
Plane landing with possible problems or injuries on board
Alert 2
Plane landing with difficulty
Alert 3
Actual Plane down