Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
18 Cards in this Set
- Front
- Back
The engine section from which bleed air is usually taken is the...
|
Compressor.
|
|
What is the approximate temperature and pressure of engine bleed as it is tapped from the engine compression section.
|
(200 psi) and (900 degrees F)
|
|
Which component determines the amount of bleed air bled from a gas turbine compressor?
|
Load control valve.
|
|
What engine bleed component prevents loss of air through the engine when it is shutdown?
|
Shutoff valve.
|
|
What component stops the flow of air to the air-conditioning system?
|
System shutoff valve.
|
|
Why are orifices installed between the air source and the airconditioning system?
|
To control the amount of bleed air drawn from the air source.
|
|
What is the bleed air system component that protects downstream components from excessive pressure by the controlling the airflow?
|
Pressure limiter.
|
|
The amount of airflow through a pressure limiter is effected by each of these (inlet pressure, inlet temperature, and differential pressure)except..
|
outlet pressure.
|
|
To remedy the limitations of a flow control valve, which bleed air system component is usually installed upstream of the flow control valve.
|
Pressure regulator and shutoff valve.
|
|
What is the bleed air system component that modulates to maintain a constant downstream air pressure.
|
Airflow regulator.
|
|
The lockout butterfly of the airflow regulator has an offset center of rotation. This design gives the butterfly a pressure that is unbalanced towards which position?
|
Closed
|
|
After replacing a bleed air system airconditioning airflow regulator fusable plug, you must also reset the...
|
Pneumatic switch.
|
|
The downstream air temperature of the bleed air air-conditioning system has exceeded the predetermined temperature. This has caused the butterfly to close. What flow control and shutoff valve component will now open?
|
Thermal switch.
|
|
The flow control valve in the bleed air air conditioning system controls flow by maintaining a constant differential pressure between the..
|
inlet and throat of the venturi
|
|
While installing a bleed air system bolted flanged face duct end, you use a new crush-type gasket, align the flange, and insert the bottom bolts first to form a cradle. Then, you install the remaining bolts and tighten all the nuts. After the installation is complete you perform an operational check that reveals a leak. From the above information what important procedure did you overlook?
|
Flange bolts were not torqued in the proper sequence.
|
|
What type of high-pressure/high-temperature ducting does not require a gasket?
|
Compressible flange.
|
|
What corrective action should be taken when a compressible flange duct end becomes distorted?
|
Reshape the duct flange ends to it's original shape.
|
|
Which lubricant can be used on a beaded channel clamp sleeve to ease installation?
|
water.
|