  • Front
  • Back
9. What device uses the fact that when an electrical current flows through a wire which has several loops placed tightly together, a magnetic field
5 What is the difference between AC and DC current.
1 ldentify the three main components of an atom, electrons nuetrons and
3Fillintheblanksfqrthedefinitionofelectricalcqry!]nt.,!Erectricar current is rhe movem *, * EfrWw' rrom a Wil,ulffwcharged object to a positively charged objec
8. An electric current produces
Write the formula for tanqent in terms of sine and cosine.
Ohms Law = V = I x R



V = Voltage I = Current x Resistance

Power equals Current times Voltage

In a series AC circuit is the instantaneous and resistance is equal in all parts of the circuit

Inductive reactance is always 90 degrees out of phase

A delta system normally does not have a neutral wire

The line voltage of a delta connected system is equal to the phase voltage

The line voltage of a wye connected system lags the phase voltage

The line current of a connected of a wye connected system is lags the phase current

The line current of a delta connected system is equal to the 1.73 phase current

Three phase alternators produce three separate voltages that how many electrical degrees 120 apart

If the phase voltage of a four wire wye connected system is 277 Volts. What is line Voltage 480 Volts

If the phase voltage of delta connected system is 277 volts the voltage is 277 volts

A delta connected system can be connected directly to wye connected

A wye connected system can have three or four wires

The two main components of an induction motor is rotor stator

The maximum rotational speed of an induction motor is called the synchronous speed

Induction motors cause current to lag voltage

The frequency of the current being fed to a motor has no effect on the speed of rotation

Synchronous motors are good for loads that require frequent stopping and starting

In a three motor continually changing phase currents in the stator windings create a rotating Magnetic Field

Soft starts lower the input voltage which results in lower torque

The line voltage and the phase voltage are equal in a delta connected system

Which type of transformer best fits the application if it is necessary to increase the primary voltage from 120 v 480 v secondary step up

A tapped transformer is used to allow for slight variations in inlet voltage

In a three phase transformer which of the Wye Primary/Alpha Secondary

A dissolved oxygen (DO) probe is considered a primary element

DCS stands for Distributive Control System

PlC stands for Programable Logic Controller

A sensor is a primary element

A thermometer is a primary element

Data is sent to the controller by the transmitter

A pressure sensor

Inductive reactance is always 90 degrees out of phase
Ohm's law is voltage equals current times resistance
The effective power value Is the same as root mean square value

Integral Control helps overcome Offset

Hertz it is the same as cycles per second
Most industrial loads are inductive
Pressure is equal t force divided by area
Venturi and Orifice meters are used for full pipe flow
Weirs are used for Open channel flowThe two types of Weirs are Broad and Sharp CrestedPalmer-Bowlus flumes are used in manholes
Current and Magnetic meters are two types of velocity meters
Hydraulic Actuator uses pressurized oil as its energy source
Synchronous Motors are good for loads that require frequent starting and stopping
True Power is the straight line on a right triangle. while Apparent Power goes up, and Apparent Power is vertical
The difference between the synchronous speed of a motor and the actual speed is called Slip
In a three phase motor the continually changing phase currents in the stator windings create a rotating magnetic field
Induction motors cause current to Lag voltage
MetersTurbine meters do not measure raw sewage flow
Reflective and Transmissive are two types of Ultrasonic Flow Meters
A pitot tube can used to measure both air and water flow
A nutating disc flow meter is often used for home water services
A diaphram is what most electromechanical sensors have in common
Open channel flow is measured with a flume
The two types of Weirs are Broad and Sharp Crested
To operate a magnetic flow meters properly it must have a full pipe of liquid