• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/33

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

33 Cards in this Set

  • Front
  • Back
according to NIOSH fatalities responding to or returning from is second only to ___
heart attacks
NFPA standard for fire apparatus driver/operator professional qual.
NFPA 1002
Standard for Firefighter prfessional qual
NFPA 1001
Standard on comprehensive occupational medical program for FD
NFPA 1582
NFPA 1582 requires ff's to have corrected visual acuity of___
20/40
NFPA 1582 recommednds rejecting candidates with hearing loss of ____ or more at frequencies of ____,_____,____ in the unaided better ear
40
500,1000,2000
NFPA 1582 recommednds rejecting candidate with loss greater than ___ in any one of four frequencies _____,_____,_____,_____
40
500-1000-2000-3000
NFPA standard for fire service vehicle operations training program.
NFPA 1451
IN the US the ____ establishes the basic requirements for licensing drivers. In Canada _____ does the same
DOT, transport Canada
the main purpose of the fd pumper is to______
supply water at adequate pressure for fire streams
NFPA standard for automotive fire apparatus
NFPA 1901
minimum pump capacity for pumpers
750gpm
industrial fire pumpers can have capacities in excess of _____
2000 gpm
industrial pumper foam tanks range from ____-_____
500-1500 gallons
most common foam tanks on municipal fire apparatus range from ___-____
20-100 gallons
small quick attack pumpers are known as____
minipumpers
pumpers that are slightly larger that minipumpers are called_____
midipumpers
the main differences between th minipumper and the midipumper are _____,_____,_____
size, pump capacity, and amount of equip carried.
size of mobile water supply apparatus depends on _____,_____,_____,_____
terrain, bridge weight limits, monetary constraints, size of other ones in the area
according to 1901, mobile water supply apparatus must carry a minimum of__________
1000 gpm
brush trucks usually have water tanks less than ____
500 gallons
NFPA standard for wildland fire apparatus
NFPA 1906
NATIONAL INCIDENT MANAGEMENT SYSTEM CATEGORIZES APPARATUS BY _______
CAPABILITY
standard for ARFF vehicles
NFPA 414
NFPA 1901 specifies that the min. pump capacity for aerial apparatus shall be ____ at ____
250 gpm, 150 psi
if an apparatus is to be considered a true quint it must have at least ___ capacity
750 gpm
an inverter converts vehicles _________ current to _______
12-24 dc, 110-220 ac
inverters can supply ____ or more of electric power
1500 watts
portable generators can provide up to ____ of power
5000 watts
vehicle mounted generators can provide up to _____ of power
12000 watts
rescue vehicles generators can provide up to ____ of power
50000 watts
portable lights generally range from ____ to _____ watts
300-1000
hydraulic power units are not capable of full power to the tool at hose lengths greater than _____
100 ft