Use LEFT and RIGHT arrow keys to navigate between flashcards;
Use UP and DOWN arrow keys to flip the card;
H to show hint;
A reads text to speech;
39 Cards in this Set
- Front
- Back
Who establishes regulaqtions regarding the rights of employees to know the potential dangers associated with hazardous chemicals in the workplace?
|
Federal Occupational Safety and Administration (OSHA)
|
|
Who must supply Material Safety Data Sheets?
|
The manufacturer.
|
|
What reference do you use to dispose hazardous chemicals?
|
MSDS
|
|
What instrument do you use to handle acid-soaked items?
|
Forceps or gloves.
|
|
What technique should personnel use when handling amalgam.
|
NO-Touch.
|
|
When should the amalgamators be inspected?
|
Weekly
|
|
In what state is dental amalgam scrap stored?
|
Dry state.
|
|
What is the preferred method of floor covering for Dental Treatment Rooms?
|
Vinyl Sheeting.
|
|
For shipboard only, mercury contaminated waste, including scrap amalgam, will be collected, and packaged with a ___________ of confinement using plastic bags, sealable drums or polethlene bottles and labeled.
|
Double Boundry
|
|
What are the two types of burns possible in Dental Treatment Facilites?
|
Thermal and Chemical
|
|
What is the Navy Enlisted Classification Code for Dental Equipment Technician?
|
DT-8732
|
|
What is the first rule for operatig and performing user maintenance on equipment?
|
Carefully read the manufacturer's instructions.
|
|
How many types of maintenance requirements are there?
|
Three
|
|
What type of maintenance is often referred to as corrective maintenance?
|
Unscheduled maintenance.
|
|
What level of maintenance requires the complete overhaul of a equipment item?
|
Level II
|
|
What is the form for the Medical/Dental Maintenance Work Order?
|
NAVMED 6700/4
|
|
What does the dental delivery system consist of?
|
Chair, unit and light
|
|
What type of headrest is the dental chair equipped with?
|
Articulating or Horse-Style headrest.
|
|
What level of maintenance for a dental delivery system when you clean the chair daily with a soft cloth dampened with soapy water?
|
Level 1
|
|
What type of Dental units are used in Navy Dentistry?
|
Mobile and Chair mounted.
|
|
What is the most common type of dental unit in use?
|
Chair mounted
|
|
What tpe of bottle is used to hold the water in the self contained water system?
|
750 ML bottle constructed of polyethylene plastic.
|
|
Most dental handpieces operate on air pressure within ___ to ___ psi range?
|
20-80
|
|
When do you remove and clean the strainer for the Central Vaccume system?
|
at least once a week
|
|
on the handpice control, what international symbol identifies the air control?
|
yellow
|
|
How long do you flush the hanpiece after each patient?
|
1 Minute
|
|
The dental light should be positioned how far from the patients face?
|
30-36 inches
|
|
The dental light rotates on how many axes?
|
3
|
|
What is used to protect the dental light bulb and reflector?
|
Light shield.
|
|
What is the Contra-Angles Speed Range?
|
380,000 to 400,000
|
|
What is the length of a smooth shank bur?
|
1/2 inch
|
|
What is the speed of the low-speed handpiece?
|
0-5,000 or 80,000 RPM depending on model.
|
|
What provides the operator a source of artificial illumination through the dental handpiece?
|
2,500 to 25,000 RPM
|
|
What is the abbreviation for friction grip?
|
FG
|
|
What are burs made of?
|
Steel or carbide
|
|
What type of bur is a #169?
|
Tapered plain fissure.
|
|
What type of bur is a #330?
|
Pear shaped.
|
|
When do you lubricate the caster bearings on the assistant's mobile chair and with what?
|
Monthly, light weight machine oil.
|
|
How do the forked prongs on the amalgamators move?
|
Figure eight.
|