• Shuffle
    Toggle On
    Toggle Off
  • Alphabetize
    Toggle On
    Toggle Off
  • Front First
    Toggle On
    Toggle Off
  • Both Sides
    Toggle On
    Toggle Off
  • Read
    Toggle On
    Toggle Off
Reading...
Front

Card Range To Study

through

image

Play button

image

Play button

image

Progress

1/100

Click to flip

Use LEFT and RIGHT arrow keys to navigate between flashcards;

Use UP and DOWN arrow keys to flip the card;

H to show hint;

A reads text to speech;

100 Cards in this Set

  • Front
  • Back

what is the fpl background and lettering if painted

red background with 2in white letters on weather decks
how far are the frame markings to be
in middle of space when <14ft and every 14 ft if >14ft
What is the shell program
ccol program
can ccol have pen and ink changes
no
what color are pen and ink changes on ccol
not allowed
how many sections of dc book
4
what are the heavy lines on dc charts
watertight and oiltight
what are light lines on dc charts
air tight and fume tight and non tight
what are the dotted lines on dc charts
hidden boundaries, pipes, and valves
what are solid lines on dc charts
visible piping
what is circle william
vent and access
what is william
piping and vents
who is responsible for the darken ship bill
DCA
what are the closure log sections
violation log and ooc log
who reports manned and ready and when
the senior person at locker when enough people are manned to do the job
who is responsible for the battle messing bill
suppo
what does the dca do for the battle messing bill
make routes
ensure one area of ship is served at a time
who decides to demolish and scuttle ship
CO
who is responsible for the scuttle ship bill
cheng
which part of the ship is the dca responsible to scuttle
fore and aft of main spaces
which part of the ship is the cheng responsible to scuttle
main spaces
NTTP 3-30.31 refers to
avoid detection
avoid targeting
avoid getting hit
minimize damage if hit
dc and restoration after hit
fighting hurt
ship priority at war
fight
move
float
ship priority at peace
return to port
safety
DC priority
fire
flood
equip
personell
Survivability considerations
command and control and comms
intense heat and smoke
personal casualties
system restoration
material stowage
who is responsible for the general emergency bill
cheng establishes procedures
what scenarios are under the general emergency bill
full crew
inport partial crew
cbr attack
abandon ship
Survivability considerations
1 Command and control
2 intense heat and smoke
3 personal casualties
4 system restoration
5 material stowage
Responsiblity for General Emergency bill
CHENG
4 scenarios of the General Emergency Bill
full crew
inport partial crew
CBR Attack
Abandon ship
General emergency bill is for what positions
Key personnel
DCA responsibilities under the General emergency bill
Supervise in DCC
Minimize damage
assist EO in salvage ops
Assist organization and training
be CBR officer
Everything CBR
What ref and chapter covers mass conflags
NTTP 3-20.31 chap 10
priorities of R&A
rescue persons from water
assit other units in distress
assist persons or activities in distress ashore
MOB-D-10
R&A
R&A MOB-D
MOB-D-10
Classification of COMMS
Primary
AUX
Supplementary (none for DC)
Emergency X40J
Electric
JA circut
CO Battle curcuit
JL
Primary battle lookout
1JV
Primary man&dock / ship control
2JV-6JV
Supplementary eng ckts
1MC
General
2MC
Engineering
3MC
Hanger deck
5MC
Flight deck
6MC
Ship to ship
1 way comms
1MC
2MC
3MC
5MC
6MC
Multiway Coms
4MC
20MC
21MC
26MC
4MC
DC
20MC
CIC
21MC
Capt command
26MC
Macinery control
Wifcom cable also called
leaky cable
plates associated with comms
Casualty power and casualty comms
Communications directory
Color of casualty comms riser on plates
Blue
ESP max temp
130 deg
ESP Discharge head
70ft -140gpm
50ft - 200gpm
when to use ESP in tandem
when discharge head is over 70ft
Perijet minimum pressure
65psi
Perijet is how much more effective than S-type
7%
Perijet Max discharge GPM
530gpm
P-100 pressure
83psi - 100 gpm
62psi - 71 gpm
Types of drainage
main
secondary
gravity
types of drainage actuation
power
gravity
combination
where are ovbd discharges found
between each main transverse blkhead
on each side of ship
on DC Deck
Colors of drainage piping
Main - green
secondary - orange
Types of ventilation
supply
exhuast
recurculation
CPS
Preheaters temp
45-65 deg
where preheaters are found
closest to intake of supply only
reheaters temp
65-80deg
where are reheaters found
upstream close to defusers on supply and recerts
Ventilation Plate
Plate 9
Types of lines and colors on the ventilation plates
thick - water tight
thin - non tight
blue - supply
red - recert
orange - natural
Exhaust ventilation components
exhuast terminal
duct work
flame arrester
fan
weather dish screen
functions of ventilation
introduce air
crew comfort
ammo preservation
electronics temp control
where in DC Book is the firemain found
Sect II e
Firepump gpm range
500-2000 gpm @150psi
Firemain diagram colors
red- firemain
blue- sprink
orange - CMWD
greean - AFFF
Purple - others
Egress training requirements
within 96hrs of checking in onboard
every 6 months
EEBD req found where
NSTM 077
req # of EEBDs onboard
shipwide 150%
for embarked crew 100%
berthings 100%
eng spaces 200%
EEBD Shelf life
15 years
how to read casualty power
2S-4P-(2-233-4)
2S- power source 2S switchboard
4 - 440 volt
P- normal ships power
(2-233-4) power panel supplied
Casualty power lead #s
1-A
2-B
3-C
Name of new type of Casualty powere
viking
Casualty power chart colors
green - permenant
red - cables
blue - risers
Casualty power found where
RPM chapt 6
Who gives permission to rig Casualty power
CO
who gives the source of Casualty power
Cheng
casualty power design features
preserves watertight integrity
easy to install
easy to operate
flexible in application
interchangeable parts
minimum space and weight requirements
steps of first aid
ABC
control bleeding
treat for shock
treat bones
transport to medical
first aid actions
report
survey area
check for response
check airway
check breathing
check circulation
stop bleeding
stretchers
stokes
miller board (backboard)
sked
army litter
reeve sleeve 2
stokes stretcher
chicken wire
miller board
plastic or wood board stretcher
sked stretcher
mummies patient
can be dragged
army litter
canvas and poles stretcher
reeves sleeve stretcher
orange padded restricting stretcher
who is responsible for assigning a medical rep to DCTT
SMR OR IDC